{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2713"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2713","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Contour extraction from HVEM image of microvessel using active contour models","abstract":"This thesis reports the research results on automatic contour extraction from high voltage electron microscope (HVEM) image of thick cross section montages of small blood vessels. The previous work on this subject, which was based on the conventional edge detection operations combined with edge linking, has proven inadequate to describe the inner structural compartments of microvessels. In this thesis, an active contour model (commonly referred to as \"Snakes\") has been applied to advance the previous work. Active contour models have proven themselves to be a powerful and flexible paradigm for many problems in image understanding, especially in contour extraction from medical images. With the developed energy functions, the active contour is attracted towards the edges under the action of internal forces (describing some elasticity properties of the contour), image forces and external forces by means of minimization of the energy functions. Based on this active model, an effective algorithm is implemented as a powerful tool for 2-D contour extraction in our problem for the first time. The results thus obtained turn out to be encouraging.","abstract_html":"This thesis reports the research results on automatic contour extraction from high voltage electron microscope (HVEM) image of thick cross section montages of small blood vessels. The previous work on this subject, which was based on the conventional edge detection operations combined with edge linking, has proven inadequate to describe the inner structural compartments of microvessels. In this thesis, an active contour model (commonly referred to as &quot;Snakes&quot;) has been applied to advance the previous work. Active contour models have proven themselves to be a powerful and flexible paradigm for many problems in image understanding, especially in contour extraction from medical images. With the developed energy functions, the active contour is attracted towards the edges under the action of internal forces (describing some elasticity properties of the contour), image forces and external forces by means of minimization of the energy functions. Based on this active model, an effective algorithm is implemented as a powerful tool for 2-D contour extraction in our problem for the first time. The results thus obtained turn out to be encouraging.","abstract_has_math":false,"creators":["Xiao, Manping"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Biomedical Engineering Committee","degree_department":null,"school":null,"contributors":["Yun Q. Shi","David S. Kristol","L. Horn"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:41:22Z","subjects":["High voltage electron microscopes.","Image processing -- Digital techniques","Blood-vessels -- Data processing","Microcirculation -- Data processing","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1706","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1706","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2713","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yun Q. Shi","David S. Kristol","L. Horn"]},{"key":"dc:creator","label":"Author","values":["Xiao, Manping"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1994-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering Committee"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["High voltage electron microscopes.","Image processing -- Digital techniques","Blood-vessels -- Data processing","Microcirculation -- Data processing","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1706"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis reports the research results on automatic contour extraction from high voltage electron microscope (HVEM) image of thick cross section montages of small blood vessels. The previous work on this subject, which was based on the conventional edge detection operations combined with edge linking, has proven inadequate to describe the inner structural compartments of microvessels. In this thesis, an active contour model (commonly referred to as \"Snakes\") has been applied to advance the previous work. Active contour models have proven themselves to be a powerful and flexible paradigm for many problems in image understanding, especially in contour extraction from medical images. With the developed energy functions, the active contour is attracted towards the edges under the action of internal forces (describing some elasticity properties of the contour), image forces and external forces by means of minimization of the energy functions. Based on this active model, an effective algorithm is implemented as a powerful tool for 2-D contour extraction in our problem for the first time. The results thus obtained turn out to be encouraging."]},{"key":"dc:title","label":"Title","values":["Contour extraction from HVEM image of microvessel using active contour models"]}]}],"canonical_facts":{"dc:contributor":["Yun Q. Shi","David S. Kristol","L. Horn"],"dc:creator":["Xiao, Manping"],"dc:date.created":["1994-01-31T08:00:00Z"],"dc:description.abstract":["This thesis reports the research results on automatic contour extraction from high voltage electron microscope (HVEM) image of thick cross section montages of small blood vessels. The previous work on this subject, which was based on the conventional edge detection operations combined with edge linking, has proven inadequate to describe the inner structural compartments of microvessels. In this thesis, an active contour model (commonly referred to as \"Snakes\") has been applied to advance the previous work. Active contour models have proven themselves to be a powerful and flexible paradigm for many problems in image understanding, especially in contour extraction from medical images. With the developed energy functions, the active contour is attracted towards the edges under the action of internal forces (describing some elasticity properties of the contour), image forces and external forces by means of minimization of the energy functions. Based on this active model, an effective algorithm is implemented as a powerful tool for 2-D contour extraction in our problem for the first time. The results thus obtained turn out to be encouraging."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1706"],"dc:subject":["High voltage electron microscopes.","Image processing -- Digital techniques","Blood-vessels -- Data processing","Microcirculation -- Data processing","Biomedical Engineering and Bioengineering"],"dc:title":["Contour extraction from HVEM image of microvessel using active contour models"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering Committee"],"thesis:degree_name":["Master of Science in Biomedical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:41:22Z"}