{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2764"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2764","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Modern techniques used to improve a hearing conservation program in a power generating plant","abstract":"A noise survey was conducted on the pump floor of a power generating plant, which included measuring noise levels at 261 areas of the floor (6,000 square feet) and the employees' noise doses, or 8-hour time-weighted average (TWAs). The noise levels of the 261 areas were recorded using a Sound Level Meter, and the noise doses (i.e., TWAs) were measured using a noise Dosimeter. It was found that both noise levels and TWAs were higher than the OSHA's permissible exposure limit (PEL) of 90 dBA and the action level of 85 dBA. According to the data gathered, it was determined that at least single hearing protection devices are mandatory while working on the pump floor after evaluating noise attenuation using both single and double hearing protection. Finally, baffles, enclosing walls, preventive maintenance, and behavior modification techniques and incentive programs are recommended in order to attenuate noise exposure levels to safety levels and improve hearing protection devices usage among employees.","abstract_html":"A noise survey was conducted on the pump floor of a power generating plant, which included measuring noise levels at 261 areas of the floor (6,000 square feet) and the employees&#x27; noise doses, or 8-hour time-weighted average (TWAs). The noise levels of the 261 areas were recorded using a Sound Level Meter, and the noise doses (i.e., TWAs) were measured using a noise Dosimeter. It was found that both noise levels and TWAs were higher than the OSHA&#x27;s permissible exposure limit (PEL) of 90 dBA and the action level of 85 dBA. According to the data gathered, it was determined that at least single hearing protection devices are mandatory while working on the pump floor after evaluating noise attenuation using both single and double hearing protection. Finally, baffles, enclosing walls, preventive maintenance, and behavior modification techniques and incentive programs are recommended in order to attenuate noise exposure levels to safety levels and improve hearing protection devices usage among employees.","abstract_has_math":false,"creators":["Fabregas, Eilyn"],"institution":null,"degree_name":"Master of Science in Occupational Safety and Health Engineering - (M.S.)","degree_level":null,"degree_discipline":"Mechanical and Industrial Engineering","degree_department":null,"school":null,"contributors":["Min-Yong Park","Howard Gage","Layek Abdel-Malek"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:41:29Z","subjects":["Power-plants -- Noise","Deafness","Noise induced -- Prevention","Occupational Health and Industrial Hygiene"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1750","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1750","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2764","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Min-Yong Park","Howard Gage","Layek Abdel-Malek"]},{"key":"dc:creator","label":"Author","values":["Fabregas, Eilyn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1993-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Industrial Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Occupational Safety and Health Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Power-plants -- Noise","Deafness","Noise induced -- Prevention","Occupational Health and Industrial Hygiene"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1750"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A noise survey was conducted on the pump floor of a power generating plant, which included measuring noise levels at 261 areas of the floor (6,000 square feet) and the employees' noise doses, or 8-hour time-weighted average (TWAs). The noise levels of the 261 areas were recorded using a Sound Level Meter, and the noise doses (i.e., TWAs) were measured using a noise Dosimeter. It was found that both noise levels and TWAs were higher than the OSHA's permissible exposure limit (PEL) of 90 dBA and the action level of 85 dBA. According to the data gathered, it was determined that at least single hearing protection devices are mandatory while working on the pump floor after evaluating noise attenuation using both single and double hearing protection. Finally, baffles, enclosing walls, preventive maintenance, and behavior modification techniques and incentive programs are recommended in order to attenuate noise exposure levels to safety levels and improve hearing protection devices usage among employees."]},{"key":"dc:title","label":"Title","values":["Modern techniques used to improve a hearing conservation program in a power generating plant"]}]}],"canonical_facts":{"dc:contributor":["Min-Yong Park","Howard Gage","Layek Abdel-Malek"],"dc:creator":["Fabregas, Eilyn"],"dc:date.created":["1993-05-31T07:00:00Z"],"dc:description.abstract":["A noise survey was conducted on the pump floor of a power generating plant, which included measuring noise levels at 261 areas of the floor (6,000 square feet) and the employees' noise doses, or 8-hour time-weighted average (TWAs). The noise levels of the 261 areas were recorded using a Sound Level Meter, and the noise doses (i.e., TWAs) were measured using a noise Dosimeter. It was found that both noise levels and TWAs were higher than the OSHA's permissible exposure limit (PEL) of 90 dBA and the action level of 85 dBA. According to the data gathered, it was determined that at least single hearing protection devices are mandatory while working on the pump floor after evaluating noise attenuation using both single and double hearing protection. Finally, baffles, enclosing walls, preventive maintenance, and behavior modification techniques and incentive programs are recommended in order to attenuate noise exposure levels to safety levels and improve hearing protection devices usage among employees."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1750"],"dc:subject":["Power-plants -- Noise","Deafness","Noise induced -- Prevention","Occupational Health and Industrial Hygiene"],"dc:title":["Modern techniques used to improve a hearing conservation program in a power generating plant"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical and Industrial Engineering"],"thesis:degree_name":["Master of Science in Occupational Safety and Health Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:41:29Z"}