{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2798"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2798","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Application of imaging pyrometry for remote temperature measurements","abstract":"The radiometric model of an IR image sensor has been developed. Based on this model, the application of imaging pyrometry to remote temperature measurements has been investigated. This analysis provides the estimation of temperature accuracy achievable by imaging pyrometry in conjunction with a number of radiometric methods. The detection of radiation emitted across the full spectral bandwidth of the imager as well as utilization of narrow-passband filters was analyzed for a target with known emissivity. The methods of two-wavelength ratio radiometry and multi-wavelength radiometry were considered for the targets with unknown emissivity. The optimal selection of the wavelengths for the method of ratio radiometry was investigated. It was shown that in the case of a blackbody radiator at 1000 C the ratio radiometry yields temperature resolution of 0.5 C for the 10^6 electrons per pixel signal level detected by 320x244 IR imager with PtSi Schottky-barrier detectors and operated with 100-nm-wide Gaussian filters positioned at 1.5 um and 3.0 u. The temperature accuracy achievable by least-squares-based multi-wavelength imaging pyrometry (MWIP) was analyzed for linear and quadratic emissivity models. The presented results have shown that for targets with quadratic spectral emissivity at 1000 C the 6-filter MWIP is capable of providing temperature resolution of about 1 C for target temperature of 1000 C and the maximum signal of 4x10^6 electrons per pixel. For targets at 500 C the corresponding accuracy is equal to 0.4 C.","abstract_html":"The radiometric model of an IR image sensor has been developed. Based on this model, the application of imaging pyrometry to remote temperature measurements has been investigated. This analysis provides the estimation of temperature accuracy achievable by imaging pyrometry in conjunction with a number of radiometric methods. The detection of radiation emitted across the full spectral bandwidth of the imager as well as utilization of narrow-passband filters was analyzed for a target with known emissivity. The methods of two-wavelength ratio radiometry and multi-wavelength radiometry were considered for the targets with unknown emissivity. The optimal selection of the wavelengths for the method of ratio radiometry was investigated. It was shown that in the case of a blackbody radiator at 1000 C the ratio radiometry yields temperature resolution of 0.5 C for the 10^6 electrons per pixel signal level detected by 320x244 IR imager with PtSi Schottky-barrier detectors and operated with 100-nm-wide Gaussian filters positioned at 1.5 um and 3.0 u. The temperature accuracy achievable by least-squares-based multi-wavelength imaging pyrometry (MWIP) was analyzed for linear and quadratic emissivity models. The presented results have shown that for targets with quadratic spectral emissivity at 1000 C the 6-filter MWIP is capable of providing temperature resolution of about 1 C for target temperature of 1000 C and the maximum signal of 4x10^6 electrons per pixel. For targets at 500 C the corresponding accuracy is equal to 0.4 C.","abstract_has_math":false,"creators":["Kaplinsky, Michael B."],"institution":null,"degree_name":"Master of Science in Electrical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Walter F. Kosonocky","Constantine N. Manikopoulos","Edwin Hou"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:41:46Z","subjects":["Pyrometers and pyrometry","Radiation -- Measurement","Temperature measurements","Remote sensing","Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1784","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1784","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2798","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Walter F. Kosonocky","Constantine N. Manikopoulos","Edwin Hou"]},{"key":"dc:creator","label":"Author","values":["Kaplinsky, Michael B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1993-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Pyrometers and pyrometry","Radiation -- Measurement","Temperature measurements","Remote sensing","Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1784"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The radiometric model of an IR image sensor has been developed. Based on this model, the application of imaging pyrometry to remote temperature measurements has been investigated. This analysis provides the estimation of temperature accuracy achievable by imaging pyrometry in conjunction with a number of radiometric methods. The detection of radiation emitted across the full spectral bandwidth of the imager as well as utilization of narrow-passband filters was analyzed for a target with known emissivity. The methods of two-wavelength ratio radiometry and multi-wavelength radiometry were considered for the targets with unknown emissivity. The optimal selection of the wavelengths for the method of ratio radiometry was investigated. It was shown that in the case of a blackbody radiator at 1000 C the ratio radiometry yields temperature resolution of 0.5 C for the 10^6 electrons per pixel signal level detected by 320x244 IR imager with PtSi Schottky-barrier detectors and operated with 100-nm-wide Gaussian filters positioned at 1.5 um and 3.0 u. The temperature accuracy achievable by least-squares-based multi-wavelength imaging pyrometry (MWIP) was analyzed for linear and quadratic emissivity models. The presented results have shown that for targets with quadratic spectral emissivity at 1000 C the 6-filter MWIP is capable of providing temperature resolution of about 1 C for target temperature of 1000 C and the maximum signal of 4x10^6 electrons per pixel. For targets at 500 C the corresponding accuracy is equal to 0.4 C."]},{"key":"dc:title","label":"Title","values":["Application of imaging pyrometry for remote temperature measurements"]}]}],"canonical_facts":{"dc:contributor":["Walter F. Kosonocky","Constantine N. Manikopoulos","Edwin Hou"],"dc:creator":["Kaplinsky, Michael B."],"dc:date.created":["1993-01-31T08:00:00Z"],"dc:description.abstract":["The radiometric model of an IR image sensor has been developed. Based on this model, the application of imaging pyrometry to remote temperature measurements has been investigated. This analysis provides the estimation of temperature accuracy achievable by imaging pyrometry in conjunction with a number of radiometric methods. The detection of radiation emitted across the full spectral bandwidth of the imager as well as utilization of narrow-passband filters was analyzed for a target with known emissivity. The methods of two-wavelength ratio radiometry and multi-wavelength radiometry were considered for the targets with unknown emissivity. The optimal selection of the wavelengths for the method of ratio radiometry was investigated. It was shown that in the case of a blackbody radiator at 1000 C the ratio radiometry yields temperature resolution of 0.5 C for the 10^6 electrons per pixel signal level detected by 320x244 IR imager with PtSi Schottky-barrier detectors and operated with 100-nm-wide Gaussian filters positioned at 1.5 um and 3.0 u. The temperature accuracy achievable by least-squares-based multi-wavelength imaging pyrometry (MWIP) was analyzed for linear and quadratic emissivity models. The presented results have shown that for targets with quadratic spectral emissivity at 1000 C the 6-filter MWIP is capable of providing temperature resolution of about 1 C for target temperature of 1000 C and the maximum signal of 4x10^6 electrons per pixel. For targets at 500 C the corresponding accuracy is equal to 0.4 C."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1784"],"dc:subject":["Pyrometers and pyrometry","Radiation -- Measurement","Temperature measurements","Remote sensing","Electrical and Electronics"],"dc:title":["Application of imaging pyrometry for remote temperature measurements"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_name":["Master of Science in Electrical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:41:46Z"}