{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2803"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2803","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Selective no absorption from gas streams with tertiary organic hydroperoxide solutions","abstract":"The selective removal of nitric oxide from gas streams was investigated using 3,6-dimethyl-3-octyl hydroperoxide, p-menthane hydroperoxide, pinane hydroperoxide, and cumene hydroperoxide in solutions of n-hexadecane (cetane). The influence of different parameters such as temperature, gas stream flow rate (or residence time), and concentration of hydroperoxide compounds on efficiency of NO removal was evaluated. The basis of this research was to duplicate atmospheric reactions between hydroperoxides and NO in order to produce NO_2. We succeeded in removing NO from gas streams, but failed to produce NO_2. NO reacted with the hydroperoxides to produce nitrates. These nitrates are easily hydrolyzed with ammonium hydroxide to ammonium nitrates and alcohols. The hydroperoxides used in this study were selected to be inexpensive and commercially available, low vapor pressure to avoid loss of reagent when contacted with hot flue gas, and easily regenerated. This research was conducted in a scrubbing reactor system with associated feed and products flow measurement equipment. The reactor consisted of a fritted disk through which a gas stream of NO in helium was bubbled into the hydroperoxide solution. Feed and effluent gas stream were analyzed using a gas chromatograph (GC) with a thermal conductivity detector (TCD) or a chemiluminescent NO_x analyzer. A Fourier transform infrared spectrometer (FTIR) was used to determine organic product distribution and an ion chromatograph (IC) was used to measure inorganic products from the hydrolysis, and from an aqueous scrubber used to detect NO_2. Higher rates of oxidation were obtained with cumene and pinane hydroperoxide than with the other two organic hydro-peroxides tested. The highest rates of NO removal were obtained at the highest temperatures, highest concentrations, and lowest gas flow rates. With p-menthane hydroperoxide as the oxidizer, the main product is p-menthane nitrate. No NO_2 was produced. Consequently, it is assumed that the main product from the other hydroperoxides is also the nitrate. In this research, excellent nitrogen mass balance were obtained to within 100 + 10% with p-menthane hydroperoxide. Again it is assumed that equivalent material balances are achieved with the other hydroperoxides. p-Menthane nitrate can be efficiently denitrated in dilute aqueous ammonia to produce ammonium nitrate and menthanol. Some experiments were conducted with hydroperoxylated polypropylene fibers as a solid oxidizer to remove NO. High rates of removal of NO was achieved at similar condtions to those used with the liquid hydroperoxides, namely, high temperature, high concentration of the hydroperoxide group, and low gas flow rate (high residence time).","abstract_html":"The selective removal of nitric oxide from gas streams was investigated using 3,6-dimethyl-3-octyl hydroperoxide, p-menthane hydroperoxide, pinane hydroperoxide, and cumene hydroperoxide in solutions of n-hexadecane (cetane). The influence of different parameters such as temperature, gas stream flow rate (or residence time), and concentration of hydroperoxide compounds on efficiency of NO removal was evaluated. The basis of this research was to duplicate atmospheric reactions between hydroperoxides and NO in order to produce NO_2. We succeeded in removing NO from gas streams, but failed to produce NO_2. NO reacted with the hydroperoxides to produce nitrates. These nitrates are easily hydrolyzed with ammonium hydroxide to ammonium nitrates and alcohols. The hydroperoxides used in this study were selected to be inexpensive and commercially available, low vapor pressure to avoid loss of reagent when contacted with hot flue gas, and easily regenerated. This research was conducted in a scrubbing reactor system with associated feed and products flow measurement equipment. The reactor consisted of a fritted disk through which a gas stream of NO in helium was bubbled into the hydroperoxide solution. Feed and effluent gas stream were analyzed using a gas chromatograph (GC) with a thermal conductivity detector (TCD) or a chemiluminescent NO_x analyzer. A Fourier transform infrared spectrometer (FTIR) was used to determine organic product distribution and an ion chromatograph (IC) was used to measure inorganic products from the hydrolysis, and from an aqueous scrubber used to detect NO_2. Higher rates of oxidation were obtained with cumene and pinane hydroperoxide than with the other two organic hydro-peroxides tested. The highest rates of NO removal were obtained at the highest temperatures, highest concentrations, and lowest gas flow rates. With p-menthane hydroperoxide as the oxidizer, the main product is p-menthane nitrate. No NO_2 was produced. Consequently, it is assumed that the main product from the other hydroperoxides is also the nitrate. In this research, excellent nitrogen mass balance were obtained to within 100 + 10% with p-menthane hydroperoxide. Again it is assumed that equivalent material balances are achieved with the other hydroperoxides. p-Menthane nitrate can be efficiently denitrated in dilute aqueous ammonia to produce ammonium nitrate and menthanol. Some experiments were conducted with hydroperoxylated polypropylene fibers as a solid oxidizer to remove NO. High rates of removal of NO was achieved at similar condtions to those used with the liquid hydroperoxides, namely, high temperature, high concentration of the hydroperoxide group, and low gas flow rate (high residence time).","abstract_has_math":false,"creators":["Ao, Huihong"],"institution":null,"degree_name":"Master of Science in Applied Chemistry - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering, Chemistry and Environmental Science","degree_department":null,"school":null,"contributors":["Henry Shaw","Howard David Perlmutter","Barbara B. Kebbekus"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:41:46Z","subjects":["Nitric oxide -- Absorption and adsorption","Nitrogen oxides","Chemistry"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1789","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1789","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2803","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Henry Shaw","Howard David Perlmutter","Barbara B. Kebbekus"]},{"key":"dc:creator","label":"Author","values":["Ao, Huihong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1992-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering, Chemistry and Environmental Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Chemistry - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nitric oxide -- Absorption and adsorption","Nitrogen oxides","Chemistry"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1789"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The selective removal of nitric oxide from gas streams was investigated using 3,6-dimethyl-3-octyl hydroperoxide, p-menthane hydroperoxide, pinane hydroperoxide, and cumene hydroperoxide in solutions of n-hexadecane (cetane). The influence of different parameters such as temperature, gas stream flow rate (or residence time), and concentration of hydroperoxide compounds on efficiency of NO removal was evaluated. The basis of this research was to duplicate atmospheric reactions between hydroperoxides and NO in order to produce NO_2. We succeeded in removing NO from gas streams, but failed to produce NO_2. NO reacted with the hydroperoxides to produce nitrates. These nitrates are easily hydrolyzed with ammonium hydroxide to ammonium nitrates and alcohols. The hydroperoxides used in this study were selected to be inexpensive and commercially available, low vapor pressure to avoid loss of reagent when contacted with hot flue gas, and easily regenerated. This research was conducted in a scrubbing reactor system with associated feed and products flow measurement equipment. The reactor consisted of a fritted disk through which a gas stream of NO in helium was bubbled into the hydroperoxide solution. Feed and effluent gas stream were analyzed using a gas chromatograph (GC) with a thermal conductivity detector (TCD) or a chemiluminescent NO_x analyzer. A Fourier transform infrared spectrometer (FTIR) was used to determine organic product distribution and an ion chromatograph (IC) was used to measure inorganic products from the hydrolysis, and from an aqueous scrubber used to detect NO_2. Higher rates of oxidation were obtained with cumene and pinane hydroperoxide than with the other two organic hydro-peroxides tested. The highest rates of NO removal were obtained at the highest temperatures, highest concentrations, and lowest gas flow rates. With p-menthane hydroperoxide as the oxidizer, the main product is p-menthane nitrate. No NO_2 was produced. Consequently, it is assumed that the main product from the other hydroperoxides is also the nitrate. In this research, excellent nitrogen mass balance were obtained to within 100 + 10% with p-menthane hydroperoxide. Again it is assumed that equivalent material balances are achieved with the other hydroperoxides. p-Menthane nitrate can be efficiently denitrated in dilute aqueous ammonia to produce ammonium nitrate and menthanol. Some experiments were conducted with hydroperoxylated polypropylene fibers as a solid oxidizer to remove NO. High rates of removal of NO was achieved at similar condtions to those used with the liquid hydroperoxides, namely, high temperature, high concentration of the hydroperoxide group, and low gas flow rate (high residence time)."]},{"key":"dc:title","label":"Title","values":["Selective no absorption from gas streams with tertiary organic hydroperoxide solutions"]}]}],"canonical_facts":{"dc:contributor":["Henry Shaw","Howard David Perlmutter","Barbara B. Kebbekus"],"dc:creator":["Ao, Huihong"],"dc:date.created":["1992-01-31T08:00:00Z"],"dc:description.abstract":["The selective removal of nitric oxide from gas streams was investigated using 3,6-dimethyl-3-octyl hydroperoxide, p-menthane hydroperoxide, pinane hydroperoxide, and cumene hydroperoxide in solutions of n-hexadecane (cetane). The influence of different parameters such as temperature, gas stream flow rate (or residence time), and concentration of hydroperoxide compounds on efficiency of NO removal was evaluated. The basis of this research was to duplicate atmospheric reactions between hydroperoxides and NO in order to produce NO_2. We succeeded in removing NO from gas streams, but failed to produce NO_2. NO reacted with the hydroperoxides to produce nitrates. These nitrates are easily hydrolyzed with ammonium hydroxide to ammonium nitrates and alcohols. The hydroperoxides used in this study were selected to be inexpensive and commercially available, low vapor pressure to avoid loss of reagent when contacted with hot flue gas, and easily regenerated. This research was conducted in a scrubbing reactor system with associated feed and products flow measurement equipment. The reactor consisted of a fritted disk through which a gas stream of NO in helium was bubbled into the hydroperoxide solution. Feed and effluent gas stream were analyzed using a gas chromatograph (GC) with a thermal conductivity detector (TCD) or a chemiluminescent NO_x analyzer. A Fourier transform infrared spectrometer (FTIR) was used to determine organic product distribution and an ion chromatograph (IC) was used to measure inorganic products from the hydrolysis, and from an aqueous scrubber used to detect NO_2. Higher rates of oxidation were obtained with cumene and pinane hydroperoxide than with the other two organic hydro-peroxides tested. The highest rates of NO removal were obtained at the highest temperatures, highest concentrations, and lowest gas flow rates. With p-menthane hydroperoxide as the oxidizer, the main product is p-menthane nitrate. No NO_2 was produced. Consequently, it is assumed that the main product from the other hydroperoxides is also the nitrate. In this research, excellent nitrogen mass balance were obtained to within 100 + 10% with p-menthane hydroperoxide. Again it is assumed that equivalent material balances are achieved with the other hydroperoxides. p-Menthane nitrate can be efficiently denitrated in dilute aqueous ammonia to produce ammonium nitrate and menthanol. Some experiments were conducted with hydroperoxylated polypropylene fibers as a solid oxidizer to remove NO. High rates of removal of NO was achieved at similar condtions to those used with the liquid hydroperoxides, namely, high temperature, high concentration of the hydroperoxide group, and low gas flow rate (high residence time)."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1789"],"dc:subject":["Nitric oxide -- Absorption and adsorption","Nitrogen oxides","Chemistry"],"dc:title":["Selective no absorption from gas streams with tertiary organic hydroperoxide solutions"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering, Chemistry and Environmental Science"],"thesis:degree_name":["Master of Science in Applied Chemistry - (M.S.)"]},"updated_at":"2026-11-19T08:41:46Z"}