{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2853"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2853","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"The effects of design parameters on the neural recordings with micro-ECoG arrays","abstract":"In the field of neural prosthetics, electro-cortico-graph (ECoG) arrays are commonly used to record neural activity of the brain cortex both in animal and human subjects. A finite element model (FEM) was developed to simulate the electric field generated by a single neuron in the rat brain cortex and a micro ECoG array (uECoG) placed on the pia surface for recording the neural signal. The neuron was simulated as a dipole current source with a magnitude of 1uA and placed at three different depths in the motor cortex corresponding to different layers under the uECoG array. The array design was a grid of 8x8 circular contacts with a contact pitch of 500 um and via holes between the recording contacts. The main hypothesis was that the presence of these holes should have significant impact on the amplitude and selectivity of the neural signals depending on the depth of the source in the cortex. The sizes of via holes were set to 20, 50, and 200 um to study their effect on the recorded potentials. These results show that the recorded signal amplitudes drop at the location of the via holes and the overall amplitudes also decreases at the contact sites as compared to the design without the holes. The larger the hole size, the larger the effect on the signal amplitude. Furthermore, the simulation results supported the hypothesis that greater potential differences were created due to the presence of holes in uECoG arrays and improved the selectivity of neural recordings.","abstract_html":"In the field of neural prosthetics, electro-cortico-graph (ECoG) arrays are commonly used to record neural activity of the brain cortex both in animal and human subjects. A finite element model (FEM) was developed to simulate the electric field generated by a single neuron in the rat brain cortex and a micro ECoG array (uECoG) placed on the pia surface for recording the neural signal. The neuron was simulated as a dipole current source with a magnitude of 1uA and placed at three different depths in the motor cortex corresponding to different layers under the uECoG array. The array design was a grid of 8x8 circular contacts with a contact pitch of 500 um and via holes between the recording contacts. The main hypothesis was that the presence of these holes should have significant impact on the amplitude and selectivity of the neural signals depending on the depth of the source in the cortex. The sizes of via holes were set to 20, 50, and 200 um to study their effect on the recorded potentials. These results show that the recorded signal amplitudes drop at the location of the via holes and the overall amplitudes also decreases at the contact sites as compared to the design without the holes. The larger the hole size, the larger the effect on the signal amplitude. Furthermore, the simulation results supported the hypothesis that greater potential differences were created due to the presence of holes in uECoG arrays and improved the selectivity of neural recordings.","abstract_has_math":false,"creators":["Sethia, Manan Amish"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Mesut Sahin","Xianlian Alex Zhou","Antje Ihlefeld"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:41:52Z","subjects":["Micro-ECoG","Rat brain model","Finite element analysis","Neural recording","Array electrodes","Neural simulation","Bioelectrical and Neuroengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1839","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1839","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2853","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mesut Sahin","Xianlian Alex Zhou","Antje Ihlefeld"]},{"key":"dc:creator","label":"Author","values":["Sethia, Manan Amish"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2021-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Micro-ECoG","Rat brain model","Finite element analysis","Neural recording","Array electrodes","Neural simulation","Bioelectrical and Neuroengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1839"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the field of neural prosthetics, electro-cortico-graph (ECoG) arrays are commonly used to record neural activity of the brain cortex both in animal and human subjects. A finite element model (FEM) was developed to simulate the electric field generated by a single neuron in the rat brain cortex and a micro ECoG array (uECoG) placed on the pia surface for recording the neural signal. The neuron was simulated as a dipole current source with a magnitude of 1uA and placed at three different depths in the motor cortex corresponding to different layers under the uECoG array. The array design was a grid of 8x8 circular contacts with a contact pitch of 500 um and via holes between the recording contacts. The main hypothesis was that the presence of these holes should have significant impact on the amplitude and selectivity of the neural signals depending on the depth of the source in the cortex. The sizes of via holes were set to 20, 50, and 200 um to study their effect on the recorded potentials. These results show that the recorded signal amplitudes drop at the location of the via holes and the overall amplitudes also decreases at the contact sites as compared to the design without the holes. The larger the hole size, the larger the effect on the signal amplitude. Furthermore, the simulation results supported the hypothesis that greater potential differences were created due to the presence of holes in uECoG arrays and improved the selectivity of neural recordings."]},{"key":"dc:title","label":"Title","values":["The effects of design parameters on the neural recordings with micro-ECoG arrays"]}]}],"canonical_facts":{"dc:contributor":["Mesut Sahin","Xianlian Alex Zhou","Antje Ihlefeld"],"dc:creator":["Sethia, Manan Amish"],"dc:date.created":["2021-05-31T07:00:00Z"],"dc:description.abstract":["In the field of neural prosthetics, electro-cortico-graph (ECoG) arrays are commonly used to record neural activity of the brain cortex both in animal and human subjects. A finite element model (FEM) was developed to simulate the electric field generated by a single neuron in the rat brain cortex and a micro ECoG array (uECoG) placed on the pia surface for recording the neural signal. The neuron was simulated as a dipole current source with a magnitude of 1uA and placed at three different depths in the motor cortex corresponding to different layers under the uECoG array. The array design was a grid of 8x8 circular contacts with a contact pitch of 500 um and via holes between the recording contacts. The main hypothesis was that the presence of these holes should have significant impact on the amplitude and selectivity of the neural signals depending on the depth of the source in the cortex. The sizes of via holes were set to 20, 50, and 200 um to study their effect on the recorded potentials. These results show that the recorded signal amplitudes drop at the location of the via holes and the overall amplitudes also decreases at the contact sites as compared to the design without the holes. The larger the hole size, the larger the effect on the signal amplitude. Furthermore, the simulation results supported the hypothesis that greater potential differences were created due to the presence of holes in uECoG arrays and improved the selectivity of neural recordings."],"dc:identifier":["https://digitalcommons.njit.edu/theses/1839"],"dc:subject":["Micro-ECoG","Rat brain model","Finite element analysis","Neural recording","Array electrodes","Neural simulation","Bioelectrical and Neuroengineering"],"dc:title":["The effects of design parameters on the neural recordings with micro-ECoG arrays"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science in Biomedical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:41:52Z"}