{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-2961"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-2961","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Preconcentration and direct flame ionization method for measurement of non-methane organic compounds in ambient air and statistical analysis of experimental data","abstract":"<p>A fast and reliable method for the determination of non-methane organic compounds (NMOC) in ambient air has been developed. Samples are collected in SUMMA polished stainless steel canisters using a sampling system with a critical orifice as flowrate controller. Analysis of NMOC in the atmosphere via a canister is carried out by cryogenic preconcentration and a direct flame ionization detection method (PDFID). This system is sensitive and provides accurate measurement of ambient NMOC concentration even if the concentration is as low as 0.1 ppm carbon. The performance of the method was characterized using 19 pairs of canister samples and tested by statistical analysis.</p>","abstract_html":"&lt;p&gt;A fast and reliable method for the determination of non-methane organic compounds (NMOC) in ambient air has been developed. Samples are collected in SUMMA polished stainless steel canisters using a sampling system with a critical orifice as flowrate controller. Analysis of NMOC in the atmosphere via a canister is carried out by cryogenic preconcentration and a direct flame ionization detection method (PDFID). This system is sensitive and provides accurate measurement of ambient NMOC concentration even if the concentration is as low as 0.1 ppm carbon. The performance of the method was characterized using 19 pairs of canister samples and tested by statistical analysis.&lt;/p&gt;","abstract_has_math":false,"creators":["Zuo, Lianyi"],"institution":null,"degree_name":"Master of Science in Environmental Science - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering, Chemistry and Environmental Science","degree_department":null,"school":null,"contributors":["Barbara B. Kebbekus","Arthur Greenberg"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:41:58Z","subjects":["Air -- Pollution -- Measurement","Environmental Sciences"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/1947","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/1947","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-2961","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Barbara B. Kebbekus","Arthur Greenberg"]},{"key":"dc:creator","label":"Author","values":["Zuo, Lianyi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1988-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering, Chemistry and Environmental Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Science - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air -- Pollution -- Measurement","Environmental Sciences"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/1947"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A fast and reliable method for the determination of non-methane organic compounds (NMOC) in ambient air has been developed. Samples are collected in SUMMA polished stainless steel canisters using a sampling system with a critical orifice as flowrate controller. Analysis of NMOC in the atmosphere via a canister is carried out by cryogenic preconcentration and a direct flame ionization detection method (PDFID). This system is sensitive and provides accurate measurement of ambient NMOC concentration even if the concentration is as low as 0.1 ppm carbon. The performance of the method was characterized using 19 pairs of canister samples and tested by statistical analysis.</p>"]},{"key":"dc:title","label":"Title","values":["Preconcentration and direct flame ionization method for measurement of non-methane organic compounds in ambient air and statistical analysis of experimental data"]}]}],"canonical_facts":{"dc:contributor":["Barbara B. Kebbekus","Arthur Greenberg"],"dc:creator":["Zuo, Lianyi"],"dc:date.created":["1988-05-31T07:00:00Z"],"dc:description.abstract":["<p>A fast and reliable method for the determination of non-methane organic compounds (NMOC) in ambient air has been developed. Samples are collected in SUMMA polished stainless steel canisters using a sampling system with a critical orifice as flowrate controller. Analysis of NMOC in the atmosphere via a canister is carried out by cryogenic preconcentration and a direct flame ionization detection method (PDFID). This system is sensitive and provides accurate measurement of ambient NMOC concentration even if the concentration is as low as 0.1 ppm carbon. The performance of the method was characterized using 19 pairs of canister samples and tested by statistical analysis.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/1947"],"dc:subject":["Air -- Pollution -- Measurement","Environmental Sciences"],"dc:title":["Preconcentration and direct flame ionization method for measurement of non-methane organic compounds in ambient air and statistical analysis of experimental data"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering, Chemistry and Environmental Science"],"thesis:degree_name":["Master of Science in Environmental Science - (M.S.)"]},"updated_at":"2026-11-19T08:41:58Z"}