{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3029"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3029","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"An experimental study of comparison between pH-parametric pumping and pH-cycling zone adsorption process on protein separation","abstract":"<p>In this thesis, an experimental investigation was conducted to compare the performance of the continuous pH-parametric pumping and the pH-cycling zone adsorption process on protein separation.</p> <p>The model system studied was hemoglobin-water. on CM-Sepharose CL-6B (cation) exchanger in a single-column system. Various modes of operation were tried on both the pH-parametric pumping and the pH-cycling zone adsorption method. The separation factors for each mode of operation were computed and compared.</p> <p>It is shown that the continuous pH-parametric pumping, with circulation to insure the pH uniformity inside the column, has the better separation factor than the pH-cycling zone adsorption method.</p>","abstract_html":"&lt;p&gt;In this thesis, an experimental investigation was conducted to compare the performance of the continuous pH-parametric pumping and the pH-cycling zone adsorption process on protein separation.&lt;/p&gt; &lt;p&gt;The model system studied was hemoglobin-water. on CM-Sepharose CL-6B (cation) exchanger in a single-column system. Various modes of operation were tried on both the pH-parametric pumping and the pH-cycling zone adsorption method. The separation factors for each mode of operation were computed and compared.&lt;/p&gt; &lt;p&gt;It is shown that the continuous pH-parametric pumping, with circulation to insure the pH uniformity inside the column, has the better separation factor than the pH-cycling zone adsorption method.&lt;/p&gt;","abstract_has_math":false,"creators":["Jajalla, Vincent P."],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering and Chemistry","degree_department":null,"school":null,"contributors":["Ching-Rong Huang","Mahmoud F. Abd-El-Bary","John E. McCormick"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:42:12Z","subjects":["Proteins -- Separation","Separation (Technology)","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2015","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2015","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3029","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ching-Rong Huang","Mahmoud F. Abd-El-Bary","John E. McCormick"]},{"key":"dc:creator","label":"Author","values":["Jajalla, Vincent P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1981-09-30T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering and Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Proteins -- Separation","Separation (Technology)","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2015"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>In this thesis, an experimental investigation was conducted to compare the performance of the continuous pH-parametric pumping and the pH-cycling zone adsorption process on protein separation.</p> <p>The model system studied was hemoglobin-water. on CM-Sepharose CL-6B (cation) exchanger in a single-column system. Various modes of operation were tried on both the pH-parametric pumping and the pH-cycling zone adsorption method. The separation factors for each mode of operation were computed and compared.</p> <p>It is shown that the continuous pH-parametric pumping, with circulation to insure the pH uniformity inside the column, has the better separation factor than the pH-cycling zone adsorption method.</p>"]},{"key":"dc:title","label":"Title","values":["An experimental study of comparison between pH-parametric pumping and pH-cycling zone adsorption process on protein separation"]}]}],"canonical_facts":{"dc:contributor":["Ching-Rong Huang","Mahmoud F. Abd-El-Bary","John E. McCormick"],"dc:creator":["Jajalla, Vincent P."],"dc:date.created":["1981-09-30T07:00:00Z"],"dc:description.abstract":["<p>In this thesis, an experimental investigation was conducted to compare the performance of the continuous pH-parametric pumping and the pH-cycling zone adsorption process on protein separation.</p> <p>The model system studied was hemoglobin-water. on CM-Sepharose CL-6B (cation) exchanger in a single-column system. Various modes of operation were tried on both the pH-parametric pumping and the pH-cycling zone adsorption method. The separation factors for each mode of operation were computed and compared.</p> <p>It is shown that the continuous pH-parametric pumping, with circulation to insure the pH uniformity inside the column, has the better separation factor than the pH-cycling zone adsorption method.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2015"],"dc:subject":["Proteins -- Separation","Separation (Technology)","Chemical Engineering"],"dc:title":["An experimental study of comparison between pH-parametric pumping and pH-cycling zone adsorption process on protein separation"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering and Chemistry"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:42:12Z"}