{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3093"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3093","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Adsorption capabilities of adsorbents for selected toxic air pollutants","abstract":"<p>The relative adsorption capacities of seven toxic, volatile organic air pollutants of either proven or suspected carcinogenic potential were tested on various adsorbents. Tests were run at flow velocities similar to those set in field sampling. This allows for extrapolation of test results to actual ambient air sampling systems. Experimentation was performed using a gas chromatograph (G.C.) equipped with a flame ionization detector. Sample introduction was carried out using the \"displacement method\" where the sample is introduced to the adsorbent cartridge as a plug.</p><p>Incipient elution volumes (V<sub>N</sub>), normalized for bulk adsorbent packing volume, were obtained at various temperatures. Plots were drawn of the In V<sub>N</sub> vs. 10<sup>3</sup>/T (Â°K) for each adsorbate-adsorbent combination. The plots all show good linearity. From the plots, results indicate that Spherocarb is by far the strongest adsorbent for the volatile organics tested while Tenax is the weakest. XAD-2 is very close to Tenax in retentiveness, but retains CCl<sub>4</sub> at the experimental flow velocity whereas Tenax does not. Porapak-T has adsorption capabilities consistently above Tenax and below Spherocarb, while Silica Gel shows a very strong retention of high boiling and water soluble compounds.</p>","abstract_html":"&lt;p&gt;The relative adsorption capacities of seven toxic, volatile organic air pollutants of either proven or suspected carcinogenic potential were tested on various adsorbents. Tests were run at flow velocities similar to those set in field sampling. This allows for extrapolation of test results to actual ambient air sampling systems. Experimentation was performed using a gas chromatograph (G.C.) equipped with a flame ionization detector. Sample introduction was carried out using the &quot;displacement method&quot; where the sample is introduced to the adsorbent cartridge as a plug.&lt;/p&gt;&lt;p&gt;Incipient elution volumes (V&lt;sub&gt;N&lt;/sub&gt;), normalized for bulk adsorbent packing volume, were obtained at various temperatures. Plots were drawn of the In V&lt;sub&gt;N&lt;/sub&gt; vs. 10&lt;sup&gt;3&lt;/sup&gt;/T (Â°K) for each adsorbate-adsorbent combination. The plots all show good linearity. From the plots, results indicate that Spherocarb is by far the strongest adsorbent for the volatile organics tested while Tenax is the weakest. XAD-2 is very close to Tenax in retentiveness, but retains CCl&lt;sub&gt;4&lt;/sub&gt; at the experimental flow velocity whereas Tenax does not. Porapak-T has adsorption capabilities consistently above Tenax and below Spherocarb, while Silica Gel shows a very strong retention of high boiling and water soluble compounds.&lt;/p&gt;","abstract_has_math":false,"creators":["Vaccaro, Richard Michael"],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Joseph W. Bozzelli","Arthur Greenberg","Barbara B. Kebbekus"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:42:12Z","subjects":["Air -- Pollution -- Measurement","Adsorption","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2079","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2079","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3093","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Joseph W. Bozzelli","Arthur Greenberg","Barbara B. Kebbekus"]},{"key":"dc:creator","label":"Author","values":["Vaccaro, Richard Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1979-10-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air -- Pollution -- Measurement","Adsorption","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2079"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The relative adsorption capacities of seven toxic, volatile organic air pollutants of either proven or suspected carcinogenic potential were tested on various adsorbents. Tests were run at flow velocities similar to those set in field sampling. This allows for extrapolation of test results to actual ambient air sampling systems. Experimentation was performed using a gas chromatograph (G.C.) equipped with a flame ionization detector. Sample introduction was carried out using the \"displacement method\" where the sample is introduced to the adsorbent cartridge as a plug.</p><p>Incipient elution volumes (V<sub>N</sub>), normalized for bulk adsorbent packing volume, were obtained at various temperatures. Plots were drawn of the In V<sub>N</sub> vs. 10<sup>3</sup>/T (Â°K) for each adsorbate-adsorbent combination. The plots all show good linearity. From the plots, results indicate that Spherocarb is by far the strongest adsorbent for the volatile organics tested while Tenax is the weakest. XAD-2 is very close to Tenax in retentiveness, but retains CCl<sub>4</sub> at the experimental flow velocity whereas Tenax does not. Porapak-T has adsorption capabilities consistently above Tenax and below Spherocarb, while Silica Gel shows a very strong retention of high boiling and water soluble compounds.</p>"]},{"key":"dc:title","label":"Title","values":["Adsorption capabilities of adsorbents for selected toxic air pollutants"]}]}],"canonical_facts":{"dc:contributor":["Joseph W. Bozzelli","Arthur Greenberg","Barbara B. Kebbekus"],"dc:creator":["Vaccaro, Richard Michael"],"dc:date.created":["1979-10-31T08:00:00Z"],"dc:description.abstract":["<p>The relative adsorption capacities of seven toxic, volatile organic air pollutants of either proven or suspected carcinogenic potential were tested on various adsorbents. Tests were run at flow velocities similar to those set in field sampling. This allows for extrapolation of test results to actual ambient air sampling systems. Experimentation was performed using a gas chromatograph (G.C.) equipped with a flame ionization detector. Sample introduction was carried out using the \"displacement method\" where the sample is introduced to the adsorbent cartridge as a plug.</p><p>Incipient elution volumes (V<sub>N</sub>), normalized for bulk adsorbent packing volume, were obtained at various temperatures. Plots were drawn of the In V<sub>N</sub> vs. 10<sup>3</sup>/T (Â°K) for each adsorbate-adsorbent combination. The plots all show good linearity. From the plots, results indicate that Spherocarb is by far the strongest adsorbent for the volatile organics tested while Tenax is the weakest. XAD-2 is very close to Tenax in retentiveness, but retains CCl<sub>4</sub> at the experimental flow velocity whereas Tenax does not. Porapak-T has adsorption capabilities consistently above Tenax and below Spherocarb, while Silica Gel shows a very strong retention of high boiling and water soluble compounds.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2079"],"dc:subject":["Air -- Pollution -- Measurement","Adsorption","Environmental Engineering"],"dc:title":["Adsorption capabilities of adsorbents for selected toxic air pollutants"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:42:12Z"}