{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3169"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3169","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"An experimental study of equilibrium parametric pumps","abstract":"<p>Parametric pumping is a separation process characterized by periodic changes in axial displacement, coupled with synchronized changes in some variable affecting the position of the interphase equilibrium. Both continuous and semicontinuous pumps were investigated at various operating conditions using a model system of toluene-n-hep-tane on a silica gel adsorbent. It has been shown that when the penetration distance for the cold cycle is less than or equal to that for the hot cycle and the height of the column, the pump has the capacity of complete removal of solute from one product stream. A quantity which is important in determining pump performance is the equilibrium parameter, b. Pump performance is enhanced by large interphase movement and hence by large values of the equilibrium parameter.</p>","abstract_html":"&lt;p&gt;Parametric pumping is a separation process characterized by periodic changes in axial displacement, coupled with synchronized changes in some variable affecting the position of the interphase equilibrium. Both continuous and semicontinuous pumps were investigated at various operating conditions using a model system of toluene-n-hep-tane on a silica gel adsorbent. It has been shown that when the penetration distance for the cold cycle is less than or equal to that for the hot cycle and the height of the column, the pump has the capacity of complete removal of solute from one product stream. A quantity which is important in determining pump performance is the equilibrium parameter, b. Pump performance is enhanced by large interphase movement and hence by large values of the equilibrium parameter.&lt;/p&gt;","abstract_has_math":false,"creators":["Park, John A."],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering and Chemistry","degree_department":null,"school":null,"contributors":["Hung T. Chen","Jerome J. Salamone","Angelo J. Perna"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:50Z","subjects":["Separation (Technology)","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2155","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2155","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3169","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hung T. Chen","Jerome J. Salamone","Angelo J. Perna"]},{"key":"dc:creator","label":"Author","values":["Park, John A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1974-01-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering and Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Separation (Technology)","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2155"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Parametric pumping is a separation process characterized by periodic changes in axial displacement, coupled with synchronized changes in some variable affecting the position of the interphase equilibrium. Both continuous and semicontinuous pumps were investigated at various operating conditions using a model system of toluene-n-hep-tane on a silica gel adsorbent. It has been shown that when the penetration distance for the cold cycle is less than or equal to that for the hot cycle and the height of the column, the pump has the capacity of complete removal of solute from one product stream. A quantity which is important in determining pump performance is the equilibrium parameter, b. Pump performance is enhanced by large interphase movement and hence by large values of the equilibrium parameter.</p>"]},{"key":"dc:title","label":"Title","values":["An experimental study of equilibrium parametric pumps"]}]}],"canonical_facts":{"dc:contributor":["Hung T. Chen","Jerome J. Salamone","Angelo J. Perna"],"dc:creator":["Park, John A."],"dc:date.created":["1974-01-31T07:00:00Z"],"dc:description.abstract":["<p>Parametric pumping is a separation process characterized by periodic changes in axial displacement, coupled with synchronized changes in some variable affecting the position of the interphase equilibrium. Both continuous and semicontinuous pumps were investigated at various operating conditions using a model system of toluene-n-hep-tane on a silica gel adsorbent. It has been shown that when the penetration distance for the cold cycle is less than or equal to that for the hot cycle and the height of the column, the pump has the capacity of complete removal of solute from one product stream. A quantity which is important in determining pump performance is the equilibrium parameter, b. Pump performance is enhanced by large interphase movement and hence by large values of the equilibrium parameter.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2155"],"dc:subject":["Separation (Technology)","Chemical Engineering"],"dc:title":["An experimental study of equilibrium parametric pumps"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering and Chemistry"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:50Z"}