{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3179"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3179","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"The effect of an electrical corona discharge upon the reaction of SO2 to SO3 in low concentration SO2 - air mixtures","abstract":"<p>An investigation of a pilot plant electrical dust precipitator was conducted to determine its ozone generating characteristics in air as well as the ability of the ozone formed to convert gaseous SO<sub>2</sub> to particulate SO<sub>3</sub>. It was anticipated that in addition to the known primary particulate dust and mist removal function of a precipitator, a secondary gaseous removal facility was inherent in its operation.</p><p>Ozone formation quantities were determined at varied air flow and electrical power input levels to the precipitator. Maximum ozone generation was 0.02 pounds per hour at an energy input level of 113 KW-HR per pound - approximately one-seventh the efficiency of commercial ozonators.</p><p>Conversion of gaseous SO<sub>2</sub> to particulate SO<sub>3</sub> by the ozone generated in the precipitator was determined at varied SO<sub>2</sub> concentration levels and air flow rates. Two definite reactions were observed in the formation of SO<sub>3</sub> from SO<sub>2</sub> by ozone. At SO<sub>2</sub> concentrations below 100 P.P.M. five mols of O<sub>3</sub> are required per mol of SO<sub>3</sub> formed whereas above SO<sub>2</sub> concentrations of 400 P.P.M. one mol of ozone produced three mols of SO<sub>3</sub>.</p><p>An evaluation of the results obtained indicates that a commercial electrical dust precipitator is an impractical device for reducing gaseous SO<sub>2</sub> by reaction of generated ozone to form particulate SO<sub>3</sub>. While 100% of the generated ozone can convert gaseous SO<sub>2</sub> to particulate SO<sub>3</sub>, the SO<sub>2</sub> concentration levels required for the reaction are such that less than 1% of the total SO<sub>2</sub> is removed from the gas stream.</p>","abstract_html":"&lt;p&gt;An investigation of a pilot plant electrical dust precipitator was conducted to determine its ozone generating characteristics in air as well as the ability of the ozone formed to convert gaseous SO&lt;sub&gt;2&lt;/sub&gt; to particulate SO&lt;sub&gt;3&lt;/sub&gt;. It was anticipated that in addition to the known primary particulate dust and mist removal function of a precipitator, a secondary gaseous removal facility was inherent in its operation.&lt;/p&gt;&lt;p&gt;Ozone formation quantities were determined at varied air flow and electrical power input levels to the precipitator. Maximum ozone generation was 0.02 pounds per hour at an energy input level of 113 KW-HR per pound - approximately one-seventh the efficiency of commercial ozonators.&lt;/p&gt;&lt;p&gt;Conversion of gaseous SO&lt;sub&gt;2&lt;/sub&gt; to particulate SO&lt;sub&gt;3&lt;/sub&gt; by the ozone generated in the precipitator was determined at varied SO&lt;sub&gt;2&lt;/sub&gt; concentration levels and air flow rates. Two definite reactions were observed in the formation of SO&lt;sub&gt;3&lt;/sub&gt; from SO&lt;sub&gt;2&lt;/sub&gt; by ozone. At SO&lt;sub&gt;2&lt;/sub&gt; concentrations below 100 P.P.M. five mols of O&lt;sub&gt;3&lt;/sub&gt; are required per mol of SO&lt;sub&gt;3&lt;/sub&gt; formed whereas above SO&lt;sub&gt;2&lt;/sub&gt; concentrations of 400 P.P.M. one mol of ozone produced three mols of SO&lt;sub&gt;3&lt;/sub&gt;.&lt;/p&gt;&lt;p&gt;An evaluation of the results obtained indicates that a commercial electrical dust precipitator is an impractical device for reducing gaseous SO&lt;sub&gt;2&lt;/sub&gt; by reaction of generated ozone to form particulate SO&lt;sub&gt;3&lt;/sub&gt;. While 100% of the generated ozone can convert gaseous SO&lt;sub&gt;2&lt;/sub&gt; to particulate SO&lt;sub&gt;3&lt;/sub&gt;, the SO&lt;sub&gt;2&lt;/sub&gt; concentration levels required for the reaction are such that less than 1% of the total SO&lt;sub&gt;2&lt;/sub&gt; is removed from the gas stream.&lt;/p&gt;","abstract_has_math":false,"creators":["Malarkey, Edward James"],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["C. L. Mantell","John E. McCormick","Deran Hanesian"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:36Z","subjects":["Electrostatic precipitation","Ozone","Sulphur dioxide","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2165","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2165","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3179","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["C. L. Mantell","John E. McCormick","Deran Hanesian"]},{"key":"dc:creator","label":"Author","values":["Malarkey, Edward James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1965-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrostatic precipitation","Ozone","Sulphur dioxide","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2165"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>An investigation of a pilot plant electrical dust precipitator was conducted to determine its ozone generating characteristics in air as well as the ability of the ozone formed to convert gaseous SO<sub>2</sub> to particulate SO<sub>3</sub>. It was anticipated that in addition to the known primary particulate dust and mist removal function of a precipitator, a secondary gaseous removal facility was inherent in its operation.</p><p>Ozone formation quantities were determined at varied air flow and electrical power input levels to the precipitator. Maximum ozone generation was 0.02 pounds per hour at an energy input level of 113 KW-HR per pound - approximately one-seventh the efficiency of commercial ozonators.</p><p>Conversion of gaseous SO<sub>2</sub> to particulate SO<sub>3</sub> by the ozone generated in the precipitator was determined at varied SO<sub>2</sub> concentration levels and air flow rates. Two definite reactions were observed in the formation of SO<sub>3</sub> from SO<sub>2</sub> by ozone. At SO<sub>2</sub> concentrations below 100 P.P.M. five mols of O<sub>3</sub> are required per mol of SO<sub>3</sub> formed whereas above SO<sub>2</sub> concentrations of 400 P.P.M. one mol of ozone produced three mols of SO<sub>3</sub>.</p><p>An evaluation of the results obtained indicates that a commercial electrical dust precipitator is an impractical device for reducing gaseous SO<sub>2</sub> by reaction of generated ozone to form particulate SO<sub>3</sub>. While 100% of the generated ozone can convert gaseous SO<sub>2</sub> to particulate SO<sub>3</sub>, the SO<sub>2</sub> concentration levels required for the reaction are such that less than 1% of the total SO<sub>2</sub> is removed from the gas stream.</p>"]},{"key":"dc:title","label":"Title","values":["The effect of an electrical corona discharge upon the reaction of SO2 to SO3 in low concentration SO2 - air mixtures"]}]}],"canonical_facts":{"dc:contributor":["C. L. Mantell","John E. McCormick","Deran Hanesian"],"dc:creator":["Malarkey, Edward James"],"dc:date.created":["1965-05-31T07:00:00Z"],"dc:description.abstract":["<p>An investigation of a pilot plant electrical dust precipitator was conducted to determine its ozone generating characteristics in air as well as the ability of the ozone formed to convert gaseous SO<sub>2</sub> to particulate SO<sub>3</sub>. It was anticipated that in addition to the known primary particulate dust and mist removal function of a precipitator, a secondary gaseous removal facility was inherent in its operation.</p><p>Ozone formation quantities were determined at varied air flow and electrical power input levels to the precipitator. Maximum ozone generation was 0.02 pounds per hour at an energy input level of 113 KW-HR per pound - approximately one-seventh the efficiency of commercial ozonators.</p><p>Conversion of gaseous SO<sub>2</sub> to particulate SO<sub>3</sub> by the ozone generated in the precipitator was determined at varied SO<sub>2</sub> concentration levels and air flow rates. Two definite reactions were observed in the formation of SO<sub>3</sub> from SO<sub>2</sub> by ozone. At SO<sub>2</sub> concentrations below 100 P.P.M. five mols of O<sub>3</sub> are required per mol of SO<sub>3</sub> formed whereas above SO<sub>2</sub> concentrations of 400 P.P.M. one mol of ozone produced three mols of SO<sub>3</sub>.</p><p>An evaluation of the results obtained indicates that a commercial electrical dust precipitator is an impractical device for reducing gaseous SO<sub>2</sub> by reaction of generated ozone to form particulate SO<sub>3</sub>. While 100% of the generated ozone can convert gaseous SO<sub>2</sub> to particulate SO<sub>3</sub>, the SO<sub>2</sub> concentration levels required for the reaction are such that less than 1% of the total SO<sub>2</sub> is removed from the gas stream.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2165"],"dc:subject":["Electrostatic precipitation","Ozone","Sulphur dioxide","Chemical Engineering"],"dc:title":["The effect of an electrical corona discharge upon the reaction of SO2 to SO3 in low concentration SO2 - air mixtures"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:36Z"}