{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3259"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3259","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Diffusion studies with novel plastics","abstract":"<p>The rates of diffusion through two fluorinated groups and two non-fluorinated groups of laboratory prepared membranes were compared with each other and with commercially available cellulose membranes. The membranes.were evaluated, in particular, for possible use with the artificial kidney. Diffusion experiments were conducted with sodium chloride, urea and uric acid. Experimental results were compared to diffusion coefficients calculated in the literature for cellulose membranes. The results show that the rates of diffusion of all of the solutes tested for the laboratory prepared membranes are comparable to that of the cellulose membranes. The fluorinated group had a slightly higher diffusion coefficient with urea than the non-fluorinated group. However, the non-fluorinated membranes had a higher diffusion coefficient by an order of magnitude over the fluorinated membranes for sodium chloride and uric acid.</p>","abstract_html":"&lt;p&gt;The rates of diffusion through two fluorinated groups and two non-fluorinated groups of laboratory prepared membranes were compared with each other and with commercially available cellulose membranes. The membranes.were evaluated, in particular, for possible use with the artificial kidney. Diffusion experiments were conducted with sodium chloride, urea and uric acid. Experimental results were compared to diffusion coefficients calculated in the literature for cellulose membranes. The results show that the rates of diffusion of all of the solutes tested for the laboratory prepared membranes are comparable to that of the cellulose membranes. The fluorinated group had a slightly higher diffusion coefficient with urea than the non-fluorinated group. However, the non-fluorinated membranes had a higher diffusion coefficient by an order of magnitude over the fluorinated membranes for sodium chloride and uric acid.&lt;/p&gt;","abstract_has_math":false,"creators":["Conway, Marion Toohey"],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering and Chemistry","degree_department":null,"school":null,"contributors":["David S. Kristol","Werner J. Wenisch","Richard Clyde Parker"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:28Z","subjects":["Plastics in surgery","Artificial kidney","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2245","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2245","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3259","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David S. Kristol","Werner J. Wenisch","Richard Clyde Parker"]},{"key":"dc:creator","label":"Author","values":["Conway, Marion Toohey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1973-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering and Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Plastics in surgery","Artificial kidney","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2245"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The rates of diffusion through two fluorinated groups and two non-fluorinated groups of laboratory prepared membranes were compared with each other and with commercially available cellulose membranes. The membranes.were evaluated, in particular, for possible use with the artificial kidney. Diffusion experiments were conducted with sodium chloride, urea and uric acid. Experimental results were compared to diffusion coefficients calculated in the literature for cellulose membranes. The results show that the rates of diffusion of all of the solutes tested for the laboratory prepared membranes are comparable to that of the cellulose membranes. The fluorinated group had a slightly higher diffusion coefficient with urea than the non-fluorinated group. However, the non-fluorinated membranes had a higher diffusion coefficient by an order of magnitude over the fluorinated membranes for sodium chloride and uric acid.</p>"]},{"key":"dc:title","label":"Title","values":["Diffusion studies with novel plastics"]}]}],"canonical_facts":{"dc:contributor":["David S. Kristol","Werner J. Wenisch","Richard Clyde Parker"],"dc:creator":["Conway, Marion Toohey"],"dc:date.created":["1973-05-31T07:00:00Z"],"dc:description.abstract":["<p>The rates of diffusion through two fluorinated groups and two non-fluorinated groups of laboratory prepared membranes were compared with each other and with commercially available cellulose membranes. The membranes.were evaluated, in particular, for possible use with the artificial kidney. Diffusion experiments were conducted with sodium chloride, urea and uric acid. Experimental results were compared to diffusion coefficients calculated in the literature for cellulose membranes. The results show that the rates of diffusion of all of the solutes tested for the laboratory prepared membranes are comparable to that of the cellulose membranes. The fluorinated group had a slightly higher diffusion coefficient with urea than the non-fluorinated group. However, the non-fluorinated membranes had a higher diffusion coefficient by an order of magnitude over the fluorinated membranes for sodium chloride and uric acid.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2245"],"dc:subject":["Plastics in surgery","Artificial kidney","Chemical Engineering"],"dc:title":["Diffusion studies with novel plastics"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering and Chemistry"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:28Z"}