{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3316"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3316","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"The study of activated sludge settleability using the solids-flux analysis","abstract":"<p>The activated sludge was cultivated in two pilot-scale activated sludge systems under three ratios of BOD to N, equal to 20:1, 70:1 and 300:1 in the influent wastewater. The aeration tank of the activated sludge system was constructed in two different configurations: one without compartments in the tank, the other consisting of six compartments. The activated sludge withdrawn from the last compartment of each system was tested in a one-liter graduate cylinder to measure its zone settling velocity. The solids-flux method was employed to analyze the sludge settling characteristic as a function of solids concentration. The results show that the activated sludge grown under the nitrogen-sufficient condition and cultivated in a compartmentalized aeration tank under the nitrogen-deficient condition were excellent in settleability. In contrast, the poor settling sludge was found in the severely limited nitrogen system and in the nitrogen-deficient system without compartments in the aeration tank. This study indicates that sufficient nitrogen in the wastewater is necessary for successful treatment of wastewater, and the compartmentalization of the aeration tank could improve the efficiency of the secondary sedimentation tank.</p>","abstract_html":"&lt;p&gt;The activated sludge was cultivated in two pilot-scale activated sludge systems under three ratios of BOD to N, equal to 20:1, 70:1 and 300:1 in the influent wastewater. The aeration tank of the activated sludge system was constructed in two different configurations: one without compartments in the tank, the other consisting of six compartments. The activated sludge withdrawn from the last compartment of each system was tested in a one-liter graduate cylinder to measure its zone settling velocity. The solids-flux method was employed to analyze the sludge settling characteristic as a function of solids concentration. The results show that the activated sludge grown under the nitrogen-sufficient condition and cultivated in a compartmentalized aeration tank under the nitrogen-deficient condition were excellent in settleability. In contrast, the poor settling sludge was found in the severely limited nitrogen system and in the nitrogen-deficient system without compartments in the aeration tank. This study indicates that sufficient nitrogen in the wastewater is necessary for successful treatment of wastewater, and the compartmentalization of the aeration tank could improve the efficiency of the secondary sedimentation tank.&lt;/p&gt;","abstract_has_math":false,"creators":["Lin, Churng-Cherng"],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Yeun C. Wu","Paul N. Cheremisinoff"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:42:25Z","subjects":["Sludge bulking","Sewage -- Purification -- Activated sludge process","Solifluction -- Analysis","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2302","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2302","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3316","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yeun C. Wu","Paul N. Cheremisinoff"]},{"key":"dc:creator","label":"Author","values":["Lin, Churng-Cherng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1992-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Sludge bulking","Sewage -- Purification -- Activated sludge process","Solifluction -- Analysis","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2302"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The activated sludge was cultivated in two pilot-scale activated sludge systems under three ratios of BOD to N, equal to 20:1, 70:1 and 300:1 in the influent wastewater. The aeration tank of the activated sludge system was constructed in two different configurations: one without compartments in the tank, the other consisting of six compartments. The activated sludge withdrawn from the last compartment of each system was tested in a one-liter graduate cylinder to measure its zone settling velocity. The solids-flux method was employed to analyze the sludge settling characteristic as a function of solids concentration. The results show that the activated sludge grown under the nitrogen-sufficient condition and cultivated in a compartmentalized aeration tank under the nitrogen-deficient condition were excellent in settleability. In contrast, the poor settling sludge was found in the severely limited nitrogen system and in the nitrogen-deficient system without compartments in the aeration tank. This study indicates that sufficient nitrogen in the wastewater is necessary for successful treatment of wastewater, and the compartmentalization of the aeration tank could improve the efficiency of the secondary sedimentation tank.</p>"]},{"key":"dc:title","label":"Title","values":["The study of activated sludge settleability using the solids-flux analysis"]}]}],"canonical_facts":{"dc:contributor":["Yeun C. Wu","Paul N. Cheremisinoff"],"dc:creator":["Lin, Churng-Cherng"],"dc:date.created":["1992-05-31T07:00:00Z"],"dc:description.abstract":["<p>The activated sludge was cultivated in two pilot-scale activated sludge systems under three ratios of BOD to N, equal to 20:1, 70:1 and 300:1 in the influent wastewater. The aeration tank of the activated sludge system was constructed in two different configurations: one without compartments in the tank, the other consisting of six compartments. The activated sludge withdrawn from the last compartment of each system was tested in a one-liter graduate cylinder to measure its zone settling velocity. The solids-flux method was employed to analyze the sludge settling characteristic as a function of solids concentration. The results show that the activated sludge grown under the nitrogen-sufficient condition and cultivated in a compartmentalized aeration tank under the nitrogen-deficient condition were excellent in settleability. In contrast, the poor settling sludge was found in the severely limited nitrogen system and in the nitrogen-deficient system without compartments in the aeration tank. This study indicates that sufficient nitrogen in the wastewater is necessary for successful treatment of wastewater, and the compartmentalization of the aeration tank could improve the efficiency of the secondary sedimentation tank.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2302"],"dc:subject":["Sludge bulking","Sewage -- Purification -- Activated sludge process","Solifluction -- Analysis","Environmental Engineering"],"dc:title":["The study of activated sludge settleability using the solids-flux analysis"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:42:25Z"}