Abstract
dc:description.abstract<p>In July 1991, Dr. Walter F. Kosonocky proposed a High-Frame-Rate-CCD Imager. The design of the imager is such that the CCD channel width be 3-microns and capable of handling at least 3000 - 5000 electrons per square micron. Using process (SUPREM III) and device (PISCES IIB) simulations, charge handling capacities as a function of implant energy and junction depth were studied. Arsenic implants ranging from 100 to 200keV were driven-in to obtain junction depths between 0.40µm and 0.80µm. As a result of this work it was determined that charge handling capacities as high as 9400 electrons/µm<sup>2</sup> were achievable with implanted doses of 1.6E12 ions/cm<sup>2</sup>. This thesis is a description of the simulation and analysis techniques used to optimize the charge handhng capacity of a 31.1m wide BCCD channel.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Electrical Engineering - (M.S.)
- Discipline thesis:degree_discipline
- Electrical and Computer Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ratner, Mark
- Contributors dc:contributor
-
- Walter F. Kosonocky
- Kenneth Sohn
- Durgamadhab Misra
Subjects
dc:subject × 3Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/theses/2337