{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3368"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3368","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Vapor-liquid equilibrium data and distillation packing evaluation at high vacuum","abstract":"<p>Vapor pressure date and vapor-liquid equilibria date at 1-30 m.m. pressure are presented for benzyl alcohol and benzyl-n-butyl ether system. Activity coefficients for the system are symetrical, the Margules constants ere A<sub>1-2</sub> = A<sub>2-1</sub>= .301. HETP values observed at a condenser pressure of 1 m.m. for 1/4\" and 3/4\" Berl saddles, 1\" Intalox saddles, Fibre Glass Combination packings # 076 and # 476, and a Knitted Wire Mesh pecking are presented as a function of the mass throughput and column pressure drop. At a condenser pressure of 1 m.m. the pressure drop per foot in terms of the mass throughput is observed for each packing. HETP values at high vacuum are greater than those observed in the same equipment at atmospheric pressure.</p>","abstract_html":"&lt;p&gt;Vapor pressure date and vapor-liquid equilibria date at 1-30 m.m. pressure are presented for benzyl alcohol and benzyl-n-butyl ether system. Activity coefficients for the system are symetrical, the Margules constants ere A&lt;sub&gt;1-2&lt;/sub&gt; = A&lt;sub&gt;2-1&lt;/sub&gt;= .301. HETP values observed at a condenser pressure of 1 m.m. for 1/4&quot; and 3/4&quot; Berl saddles, 1&quot; Intalox saddles, Fibre Glass Combination packings # 076 and # 476, and a Knitted Wire Mesh pecking are presented as a function of the mass throughput and column pressure drop. At a condenser pressure of 1 m.m. the pressure drop per foot in terms of the mass throughput is observed for each packing. HETP values at high vacuum are greater than those observed in the same equipment at atmospheric pressure.&lt;/p&gt;","abstract_has_math":false,"creators":["Lasch, Edward Joseph"],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Edward G. Scheibel","Joseph Joffe","George C. Keeffe"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:36Z","subjects":["Chemical equilibrium","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2354","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2354","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3368","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Edward G. Scheibel","Joseph Joffe","George C. Keeffe"]},{"key":"dc:creator","label":"Author","values":["Lasch, Edward Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1955-06-30T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical equilibrium","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2354"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Vapor pressure date and vapor-liquid equilibria date at 1-30 m.m. pressure are presented for benzyl alcohol and benzyl-n-butyl ether system. Activity coefficients for the system are symetrical, the Margules constants ere A<sub>1-2</sub> = A<sub>2-1</sub>= .301. HETP values observed at a condenser pressure of 1 m.m. for 1/4\" and 3/4\" Berl saddles, 1\" Intalox saddles, Fibre Glass Combination packings # 076 and # 476, and a Knitted Wire Mesh pecking are presented as a function of the mass throughput and column pressure drop. At a condenser pressure of 1 m.m. the pressure drop per foot in terms of the mass throughput is observed for each packing. HETP values at high vacuum are greater than those observed in the same equipment at atmospheric pressure.</p>"]},{"key":"dc:title","label":"Title","values":["Vapor-liquid equilibrium data and distillation packing evaluation at high vacuum"]}]}],"canonical_facts":{"dc:contributor":["Edward G. Scheibel","Joseph Joffe","George C. Keeffe"],"dc:creator":["Lasch, Edward Joseph"],"dc:date.created":["1955-06-30T07:00:00Z"],"dc:description.abstract":["<p>Vapor pressure date and vapor-liquid equilibria date at 1-30 m.m. pressure are presented for benzyl alcohol and benzyl-n-butyl ether system. Activity coefficients for the system are symetrical, the Margules constants ere A<sub>1-2</sub> = A<sub>2-1</sub>= .301. HETP values observed at a condenser pressure of 1 m.m. for 1/4\" and 3/4\" Berl saddles, 1\" Intalox saddles, Fibre Glass Combination packings # 076 and # 476, and a Knitted Wire Mesh pecking are presented as a function of the mass throughput and column pressure drop. At a condenser pressure of 1 m.m. the pressure drop per foot in terms of the mass throughput is observed for each packing. HETP values at high vacuum are greater than those observed in the same equipment at atmospheric pressure.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2354"],"dc:subject":["Chemical equilibrium","Chemical Engineering"],"dc:title":["Vapor-liquid equilibrium data and distillation packing evaluation at high vacuum"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:36Z"}