{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3452"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3452","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Development of an apparatus to obtain temperature profiles of molten flowing polymers","abstract":"<p>The object of this investigation is to develop and test an apparatus to predict temperature profiles of polymer melts in laminar flow in a heat exchanger, with non-isothermal wall conditions.</p><p>A commercial polyethylene melt is pumped at various flow rates through a smooth 0.957 in. I.D. pipe. The entrance temperature of polymer is maintained uniform.</p><p>Radially distributed six thermocouples (0.062 in. 0.D.) are placed at 2.5 ft. intervals from the entrance of heat exchanger. Immersion of these probes parallel to the flow direction, reduced the errors due to the conduction of heat from the tube wall to the thermocouple stems.</p><p>The experimental data, calculated viscous heating factors and obtained Nusselt-Graetz data are compared with previous works.</p><p>The results agreed with those theoretical studies which consider the viscous heating of polymer melts as a significant flow character. This study revealed that the viscous heating effects are too important to neglect and that the heat transfer phenomena is strongly dependent on viscous heating and the expansion-cooling of the polymer melt. The viscoelastic behavior, that is attributed to polymer melts, is the major cause of viscous heating.</p><p>The literature review has shown that there is no experimental work accomplished to investigate the temperature profile development of polymer melts.</p>","abstract_html":"&lt;p&gt;The object of this investigation is to develop and test an apparatus to predict temperature profiles of polymer melts in laminar flow in a heat exchanger, with non-isothermal wall conditions.&lt;/p&gt;&lt;p&gt;A commercial polyethylene melt is pumped at various flow rates through a smooth 0.957 in. I.D. pipe. The entrance temperature of polymer is maintained uniform.&lt;/p&gt;&lt;p&gt;Radially distributed six thermocouples (0.062 in. 0.D.) are placed at 2.5 ft. intervals from the entrance of heat exchanger. Immersion of these probes parallel to the flow direction, reduced the errors due to the conduction of heat from the tube wall to the thermocouple stems.&lt;/p&gt;&lt;p&gt;The experimental data, calculated viscous heating factors and obtained Nusselt-Graetz data are compared with previous works.&lt;/p&gt;&lt;p&gt;The results agreed with those theoretical studies which consider the viscous heating of polymer melts as a significant flow character. This study revealed that the viscous heating effects are too important to neglect and that the heat transfer phenomena is strongly dependent on viscous heating and the expansion-cooling of the polymer melt. The viscoelastic behavior, that is attributed to polymer melts, is the major cause of viscous heating.&lt;/p&gt;&lt;p&gt;The literature review has shown that there is no experimental work accomplished to investigate the temperature profile development of polymer melts.&lt;/p&gt;","abstract_has_math":false,"creators":["Saltuk, Ismail Kemal"],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering and Chemistry","degree_department":null,"school":null,"contributors":["Richard G. Griskey","Hung T. Chen","Deran Hanesian"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:50Z","subjects":["Polymers and polymerization -- Thermal properties -- Testing","Heat exchangers -- Design and construction","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2438","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2438","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3452","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Richard G. Griskey","Hung T. Chen","Deran Hanesian"]},{"key":"dc:creator","label":"Author","values":["Saltuk, Ismail Kemal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1970-10-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering and Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Polymers and polymerization -- Thermal properties -- Testing","Heat exchangers -- Design and construction","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2438"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The object of this investigation is to develop and test an apparatus to predict temperature profiles of polymer melts in laminar flow in a heat exchanger, with non-isothermal wall conditions.</p><p>A commercial polyethylene melt is pumped at various flow rates through a smooth 0.957 in. I.D. pipe. The entrance temperature of polymer is maintained uniform.</p><p>Radially distributed six thermocouples (0.062 in. 0.D.) are placed at 2.5 ft. intervals from the entrance of heat exchanger. Immersion of these probes parallel to the flow direction, reduced the errors due to the conduction of heat from the tube wall to the thermocouple stems.</p><p>The experimental data, calculated viscous heating factors and obtained Nusselt-Graetz data are compared with previous works.</p><p>The results agreed with those theoretical studies which consider the viscous heating of polymer melts as a significant flow character. This study revealed that the viscous heating effects are too important to neglect and that the heat transfer phenomena is strongly dependent on viscous heating and the expansion-cooling of the polymer melt. The viscoelastic behavior, that is attributed to polymer melts, is the major cause of viscous heating.</p><p>The literature review has shown that there is no experimental work accomplished to investigate the temperature profile development of polymer melts.</p>"]},{"key":"dc:title","label":"Title","values":["Development of an apparatus to obtain temperature profiles of molten flowing polymers"]}]}],"canonical_facts":{"dc:contributor":["Richard G. Griskey","Hung T. Chen","Deran Hanesian"],"dc:creator":["Saltuk, Ismail Kemal"],"dc:date.created":["1970-10-31T08:00:00Z"],"dc:description.abstract":["<p>The object of this investigation is to develop and test an apparatus to predict temperature profiles of polymer melts in laminar flow in a heat exchanger, with non-isothermal wall conditions.</p><p>A commercial polyethylene melt is pumped at various flow rates through a smooth 0.957 in. I.D. pipe. The entrance temperature of polymer is maintained uniform.</p><p>Radially distributed six thermocouples (0.062 in. 0.D.) are placed at 2.5 ft. intervals from the entrance of heat exchanger. Immersion of these probes parallel to the flow direction, reduced the errors due to the conduction of heat from the tube wall to the thermocouple stems.</p><p>The experimental data, calculated viscous heating factors and obtained Nusselt-Graetz data are compared with previous works.</p><p>The results agreed with those theoretical studies which consider the viscous heating of polymer melts as a significant flow character. This study revealed that the viscous heating effects are too important to neglect and that the heat transfer phenomena is strongly dependent on viscous heating and the expansion-cooling of the polymer melt. The viscoelastic behavior, that is attributed to polymer melts, is the major cause of viscous heating.</p><p>The literature review has shown that there is no experimental work accomplished to investigate the temperature profile development of polymer melts.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2438"],"dc:subject":["Polymers and polymerization -- Thermal properties -- Testing","Heat exchangers -- Design and construction","Chemical Engineering"],"dc:title":["Development of an apparatus to obtain temperature profiles of molten flowing polymers"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering and Chemistry"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:50Z"}