{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3496"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3496","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Deconvolution applications in arterial dynamics","abstract":"<p>This thesis deals with the computation of the Arterial Impulse Response Function by deconvolving aortic pressure and flow signals in time domain. Several methods have been developed in the past to obtain a solution for the convolution integral. These are (1) Transform method, and (2) Numerical Approximation methods : a. Conventional method b. Relaxation methods.</p><p>These methods have been applied in the past to the RC network model and it was found to work well. In this thesis, the methods are applied to data from more realistic models and also on data obtained from dogs. The model considered is a 3-element Windkessel model. Studies were conducted in two situations in dogs - one under control situation which is to be compared with the Windkessel model and then under occlusion conditions, with aortic occlusion and occlusion of both carotid arteries.</p><p>The parameters of interest in this study of the arterial system in time domain are the total arterial compliance and wave reflections. Reflection studies are made from the impulse response function of the dogs under occlusion conditions.</p>","abstract_html":"&lt;p&gt;This thesis deals with the computation of the Arterial Impulse Response Function by deconvolving aortic pressure and flow signals in time domain. Several methods have been developed in the past to obtain a solution for the convolution integral. These are (1) Transform method, and (2) Numerical Approximation methods : a. Conventional method b. Relaxation methods.&lt;/p&gt;&lt;p&gt;These methods have been applied in the past to the RC network model and it was found to work well. In this thesis, the methods are applied to data from more realistic models and also on data obtained from dogs. The model considered is a 3-element Windkessel model. Studies were conducted in two situations in dogs - one under control situation which is to be compared with the Windkessel model and then under occlusion conditions, with aortic occlusion and occlusion of both carotid arteries.&lt;/p&gt;&lt;p&gt;The parameters of interest in this study of the arterial system in time domain are the total arterial compliance and wave reflections. Reflection studies are made from the impulse response function of the dogs under occlusion conditions.&lt;/p&gt;","abstract_has_math":false,"creators":["Ganesan, Shanthi"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Biomedical Engineering Committee","degree_department":null,"school":null,"contributors":["Peter Engler","David S. Kristol","Swamy Laxminarayan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:42:32Z","subjects":["Arteries -- Physiology","Blood flow","Frequency response (Dynamics)","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2482","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2482","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3496","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Peter Engler","David S. Kristol","Swamy Laxminarayan"]},{"key":"dc:creator","label":"Author","values":["Ganesan, Shanthi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1991-09-30T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering Committee"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Arteries -- Physiology","Blood flow","Frequency response (Dynamics)","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2482"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>This thesis deals with the computation of the Arterial Impulse Response Function by deconvolving aortic pressure and flow signals in time domain. Several methods have been developed in the past to obtain a solution for the convolution integral. These are (1) Transform method, and (2) Numerical Approximation methods : a. Conventional method b. Relaxation methods.</p><p>These methods have been applied in the past to the RC network model and it was found to work well. In this thesis, the methods are applied to data from more realistic models and also on data obtained from dogs. The model considered is a 3-element Windkessel model. Studies were conducted in two situations in dogs - one under control situation which is to be compared with the Windkessel model and then under occlusion conditions, with aortic occlusion and occlusion of both carotid arteries.</p><p>The parameters of interest in this study of the arterial system in time domain are the total arterial compliance and wave reflections. Reflection studies are made from the impulse response function of the dogs under occlusion conditions.</p>"]},{"key":"dc:title","label":"Title","values":["Deconvolution applications in arterial dynamics"]}]}],"canonical_facts":{"dc:contributor":["Peter Engler","David S. Kristol","Swamy Laxminarayan"],"dc:creator":["Ganesan, Shanthi"],"dc:date.created":["1991-09-30T07:00:00Z"],"dc:description.abstract":["<p>This thesis deals with the computation of the Arterial Impulse Response Function by deconvolving aortic pressure and flow signals in time domain. Several methods have been developed in the past to obtain a solution for the convolution integral. These are (1) Transform method, and (2) Numerical Approximation methods : a. Conventional method b. Relaxation methods.</p><p>These methods have been applied in the past to the RC network model and it was found to work well. In this thesis, the methods are applied to data from more realistic models and also on data obtained from dogs. The model considered is a 3-element Windkessel model. Studies were conducted in two situations in dogs - one under control situation which is to be compared with the Windkessel model and then under occlusion conditions, with aortic occlusion and occlusion of both carotid arteries.</p><p>The parameters of interest in this study of the arterial system in time domain are the total arterial compliance and wave reflections. Reflection studies are made from the impulse response function of the dogs under occlusion conditions.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2482"],"dc:subject":["Arteries -- Physiology","Blood flow","Frequency response (Dynamics)","Biomedical Engineering and Bioengineering"],"dc:title":["Deconvolution applications in arterial dynamics"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering Committee"],"thesis:degree_name":["Master of Science in Biomedical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:42:32Z"}