{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3610"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3610","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Adsorption of carbon dioxide by sodium carbonate solutions in a gas-bubble column","abstract":"<p>A study was conducted on the absorption of pure carbon dioxide by sodium carbonate-sodium bicarabonate systems in a gas-bubble column (in which bubbles, formed by passing a gas through a porous plate at the base of to column, rise up through a descending continuous liquid phase). This equipment was found to be entremely effcient, under the condtions of the experiments, covered liquid rates (9,000 to 13,000 pounds per hour per square foot) with gas rates of 30 to 60 pounds per hour or square foot. The absorption section of the column was two inches in diameter and one foot in height. Sodium carbonate normalities were varied from 0 to 1.2 normal with bicarbonate fractions ranging from 0 to 0.65. The effects of temperature, column height, and column diameter were not investigated.</p><p>A correlation equation was obtained for Kga at 25Â° Centigrade and one foot column height which gave agreement with the main body of data to within ?8%.</p><p>Kga = 1.00x10<sup>-4</sup> L<sup>0.834</sup> G<sup>0.308</sup> (0.800 ? 0.110N)16mols/hr-ft<sup>3</sup>-atm.</p><p>The values of Kga obtained were as much as five times greater those given in the literature for packed towers.</p><p>A qualitative analysis or the data Indicated that to process was probably primarily one controlled by diffusion of the carbon dioxide through the liquid film, the sodium carbonate serving mainly to prevent a buildup of carbon dioxide back pressure.</p>","abstract_html":"&lt;p&gt;A study was conducted on the absorption of pure carbon dioxide by sodium carbonate-sodium bicarabonate systems in a gas-bubble column (in which bubbles, formed by passing a gas through a porous plate at the base of to column, rise up through a descending continuous liquid phase). This equipment was found to be entremely effcient, under the condtions of the experiments, covered liquid rates (9,000 to 13,000 pounds per hour per square foot) with gas rates of 30 to 60 pounds per hour or square foot. The absorption section of the column was two inches in diameter and one foot in height. Sodium carbonate normalities were varied from 0 to 1.2 normal with bicarbonate fractions ranging from 0 to 0.65. The effects of temperature, column height, and column diameter were not investigated.&lt;/p&gt;&lt;p&gt;A correlation equation was obtained for Kga at 25Â° Centigrade and one foot column height which gave agreement with the main body of data to within ?8%.&lt;/p&gt;&lt;p&gt;Kga = 1.00x10&lt;sup&gt;-4&lt;/sup&gt; L&lt;sup&gt;0.834&lt;/sup&gt; G&lt;sup&gt;0.308&lt;/sup&gt; (0.800 ? 0.110N)16mols/hr-ft&lt;sup&gt;3&lt;/sup&gt;-atm.&lt;/p&gt;&lt;p&gt;The values of Kga obtained were as much as five times greater those given in the literature for packed towers.&lt;/p&gt;&lt;p&gt;A qualitative analysis or the data Indicated that to process was probably primarily one controlled by diffusion of the carbon dioxide through the liquid film, the sodium carbonate serving mainly to prevent a buildup of carbon dioxide back pressure.&lt;/p&gt;","abstract_has_math":false,"creators":["Singalewitch, Joseph Don"],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Joseph Joffe","George C. Keeffe","C. L. Mantell"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:50Z","subjects":["Gases -- Absorption and adsorption","Carbon dioxide","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2596","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2596","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3610","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Joseph Joffe","George C. Keeffe","C. L. Mantell"]},{"key":"dc:creator","label":"Author","values":["Singalewitch, Joseph Don"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1957-06-30T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gases -- Absorption and adsorption","Carbon dioxide","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2596"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A study was conducted on the absorption of pure carbon dioxide by sodium carbonate-sodium bicarabonate systems in a gas-bubble column (in which bubbles, formed by passing a gas through a porous plate at the base of to column, rise up through a descending continuous liquid phase). This equipment was found to be entremely effcient, under the condtions of the experiments, covered liquid rates (9,000 to 13,000 pounds per hour per square foot) with gas rates of 30 to 60 pounds per hour or square foot. The absorption section of the column was two inches in diameter and one foot in height. Sodium carbonate normalities were varied from 0 to 1.2 normal with bicarbonate fractions ranging from 0 to 0.65. The effects of temperature, column height, and column diameter were not investigated.</p><p>A correlation equation was obtained for Kga at 25Â° Centigrade and one foot column height which gave agreement with the main body of data to within ?8%.</p><p>Kga = 1.00x10<sup>-4</sup> L<sup>0.834</sup> G<sup>0.308</sup> (0.800 ? 0.110N)16mols/hr-ft<sup>3</sup>-atm.</p><p>The values of Kga obtained were as much as five times greater those given in the literature for packed towers.</p><p>A qualitative analysis or the data Indicated that to process was probably primarily one controlled by diffusion of the carbon dioxide through the liquid film, the sodium carbonate serving mainly to prevent a buildup of carbon dioxide back pressure.</p>"]},{"key":"dc:title","label":"Title","values":["Adsorption of carbon dioxide by sodium carbonate solutions in a gas-bubble column"]}]}],"canonical_facts":{"dc:contributor":["Joseph Joffe","George C. Keeffe","C. L. Mantell"],"dc:creator":["Singalewitch, Joseph Don"],"dc:date.created":["1957-06-30T07:00:00Z"],"dc:description.abstract":["<p>A study was conducted on the absorption of pure carbon dioxide by sodium carbonate-sodium bicarabonate systems in a gas-bubble column (in which bubbles, formed by passing a gas through a porous plate at the base of to column, rise up through a descending continuous liquid phase). This equipment was found to be entremely effcient, under the condtions of the experiments, covered liquid rates (9,000 to 13,000 pounds per hour per square foot) with gas rates of 30 to 60 pounds per hour or square foot. The absorption section of the column was two inches in diameter and one foot in height. Sodium carbonate normalities were varied from 0 to 1.2 normal with bicarbonate fractions ranging from 0 to 0.65. The effects of temperature, column height, and column diameter were not investigated.</p><p>A correlation equation was obtained for Kga at 25Â° Centigrade and one foot column height which gave agreement with the main body of data to within ?8%.</p><p>Kga = 1.00x10<sup>-4</sup> L<sup>0.834</sup> G<sup>0.308</sup> (0.800 ? 0.110N)16mols/hr-ft<sup>3</sup>-atm.</p><p>The values of Kga obtained were as much as five times greater those given in the literature for packed towers.</p><p>A qualitative analysis or the data Indicated that to process was probably primarily one controlled by diffusion of the carbon dioxide through the liquid film, the sodium carbonate serving mainly to prevent a buildup of carbon dioxide back pressure.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2596"],"dc:subject":["Gases -- Absorption and adsorption","Carbon dioxide","Chemical Engineering"],"dc:title":["Adsorption of carbon dioxide by sodium carbonate solutions in a gas-bubble column"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:50Z"}