{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3645"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3645","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Gas chromatographic method for determination of 28 volatile organic compounds emitted from a sewerage plant","abstract":"<p>In this study, 28 volatile organic compounds (VOCs) emitted from the Linden Roselle Sewerage Authority Plant (LRSA) were monitered. The determination by gas chromatography (GC) is presented. This work emphasizes the collection of whole air samples, using a canister-based sampling system with cryogenic concentration. An appropriate temperature program was selected to obtain the best sample separation. The procedure for the identification of 28 standard gas mixture was achieved by comparing the chromatograms of sample with those of the specific groups of target compounds, as well as by comparing the sample with the results from GC Mass spectrometeric analysis. Because of the high humidity of the air samples collected above the surface of the water, the polar compounds tend to deposit on the wall of the canister, the transfer lines and the capillary column of GC. Both the canister cleaning method and the temperature program of GC were improved. A quality assurance protocol for the analytical system was set up and the minimum detection limits have also been determined.</p>","abstract_html":"&lt;p&gt;In this study, 28 volatile organic compounds (VOCs) emitted from the Linden Roselle Sewerage Authority Plant (LRSA) were monitered. The determination by gas chromatography (GC) is presented. This work emphasizes the collection of whole air samples, using a canister-based sampling system with cryogenic concentration. An appropriate temperature program was selected to obtain the best sample separation. The procedure for the identification of 28 standard gas mixture was achieved by comparing the chromatograms of sample with those of the specific groups of target compounds, as well as by comparing the sample with the results from GC Mass spectrometeric analysis. Because of the high humidity of the air samples collected above the surface of the water, the polar compounds tend to deposit on the wall of the canister, the transfer lines and the capillary column of GC. Both the canister cleaning method and the temperature program of GC were improved. A quality assurance protocol for the analytical system was set up and the minimum detection limits have also been determined.&lt;/p&gt;","abstract_has_math":false,"creators":["Sun, Yeming"],"institution":null,"degree_name":"Master of Science in Environmental Science - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering, Chemistry and Environmental Science","degree_department":null,"school":null,"contributors":["Anthony Kahng","Leonard Dauerman","Richard B. Trattner"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:42:44Z","subjects":["Gas chromatography","Organic compounds","Sewage disposal plants","Environmental Sciences","Toxicology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2631","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2631","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3645","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Anthony Kahng","Leonard Dauerman","Richard B. Trattner"]},{"key":"dc:creator","label":"Author","values":["Sun, Yeming"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1991-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering, Chemistry and Environmental Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Science - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gas chromatography","Organic compounds","Sewage disposal plants","Environmental Sciences","Toxicology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2631"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>In this study, 28 volatile organic compounds (VOCs) emitted from the Linden Roselle Sewerage Authority Plant (LRSA) were monitered. The determination by gas chromatography (GC) is presented. This work emphasizes the collection of whole air samples, using a canister-based sampling system with cryogenic concentration. An appropriate temperature program was selected to obtain the best sample separation. The procedure for the identification of 28 standard gas mixture was achieved by comparing the chromatograms of sample with those of the specific groups of target compounds, as well as by comparing the sample with the results from GC Mass spectrometeric analysis. Because of the high humidity of the air samples collected above the surface of the water, the polar compounds tend to deposit on the wall of the canister, the transfer lines and the capillary column of GC. Both the canister cleaning method and the temperature program of GC were improved. A quality assurance protocol for the analytical system was set up and the minimum detection limits have also been determined.</p>"]},{"key":"dc:title","label":"Title","values":["Gas chromatographic method for determination of 28 volatile organic compounds emitted from a sewerage plant"]}]}],"canonical_facts":{"dc:contributor":["Anthony Kahng","Leonard Dauerman","Richard B. Trattner"],"dc:creator":["Sun, Yeming"],"dc:date.created":["1991-01-31T08:00:00Z"],"dc:description.abstract":["<p>In this study, 28 volatile organic compounds (VOCs) emitted from the Linden Roselle Sewerage Authority Plant (LRSA) were monitered. The determination by gas chromatography (GC) is presented. This work emphasizes the collection of whole air samples, using a canister-based sampling system with cryogenic concentration. An appropriate temperature program was selected to obtain the best sample separation. The procedure for the identification of 28 standard gas mixture was achieved by comparing the chromatograms of sample with those of the specific groups of target compounds, as well as by comparing the sample with the results from GC Mass spectrometeric analysis. Because of the high humidity of the air samples collected above the surface of the water, the polar compounds tend to deposit on the wall of the canister, the transfer lines and the capillary column of GC. Both the canister cleaning method and the temperature program of GC were improved. A quality assurance protocol for the analytical system was set up and the minimum detection limits have also been determined.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2631"],"dc:subject":["Gas chromatography","Organic compounds","Sewage disposal plants","Environmental Sciences","Toxicology"],"dc:title":["Gas chromatographic method for determination of 28 volatile organic compounds emitted from a sewerage plant"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering, Chemistry and Environmental Science"],"thesis:degree_name":["Master of Science in Environmental Science - (M.S.)"]},"updated_at":"2026-11-19T08:42:44Z"}