{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3861"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3861","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Red blood cell deformability testing by using a rheological method","abstract":"<p>A rheological model of blood has been used for testing red cell deformability. The result of the testing is characterized by five parameters of the model. We suggested that the rheological behavior of blood is affected by red cell deformability. The result of the parameter C of the model, which is the kinetic rate constant of the structural breakdown of rouleaux into individual erythrocytes induced by shearing, from decreased red cell deformability group higher than that from normal control group lead to a criterion for separating normal subjects from decreased red cell deformability. The easy experiment method of using whole blood sample directly for testing red cell deformability is the goal of introducing this hemorheological testing.</p>","abstract_html":"&lt;p&gt;A rheological model of blood has been used for testing red cell deformability. The result of the testing is characterized by five parameters of the model. We suggested that the rheological behavior of blood is affected by red cell deformability. The result of the parameter C of the model, which is the kinetic rate constant of the structural breakdown of rouleaux into individual erythrocytes induced by shearing, from decreased red cell deformability group higher than that from normal control group lead to a criterion for separating normal subjects from decreased red cell deformability. The easy experiment method of using whole blood sample directly for testing red cell deformability is the goal of introducing this hemorheological testing.&lt;/p&gt;","abstract_has_math":false,"creators":["Ma, Zhenglei"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Biomedical Engineering Committee","degree_department":null,"school":null,"contributors":["Ching-Rong Huang","David S. Kristol","Peter Engler"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:42:55Z","subjects":["Blood -- Rheology","Erythrocytes -- Testing","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2847","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2847","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3861","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ching-Rong Huang","David S. Kristol","Peter Engler"]},{"key":"dc:creator","label":"Author","values":["Ma, Zhenglei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1989-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering Committee"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Blood -- Rheology","Erythrocytes -- Testing","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2847"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A rheological model of blood has been used for testing red cell deformability. The result of the testing is characterized by five parameters of the model. We suggested that the rheological behavior of blood is affected by red cell deformability. The result of the parameter C of the model, which is the kinetic rate constant of the structural breakdown of rouleaux into individual erythrocytes induced by shearing, from decreased red cell deformability group higher than that from normal control group lead to a criterion for separating normal subjects from decreased red cell deformability. The easy experiment method of using whole blood sample directly for testing red cell deformability is the goal of introducing this hemorheological testing.</p>"]},{"key":"dc:title","label":"Title","values":["Red blood cell deformability testing by using a rheological method"]}]}],"canonical_facts":{"dc:contributor":["Ching-Rong Huang","David S. Kristol","Peter Engler"],"dc:creator":["Ma, Zhenglei"],"dc:date.created":["1989-05-31T07:00:00Z"],"dc:description.abstract":["<p>A rheological model of blood has been used for testing red cell deformability. The result of the testing is characterized by five parameters of the model. We suggested that the rheological behavior of blood is affected by red cell deformability. The result of the parameter C of the model, which is the kinetic rate constant of the structural breakdown of rouleaux into individual erythrocytes induced by shearing, from decreased red cell deformability group higher than that from normal control group lead to a criterion for separating normal subjects from decreased red cell deformability. The easy experiment method of using whole blood sample directly for testing red cell deformability is the goal of introducing this hemorheological testing.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2847"],"dc:subject":["Blood -- Rheology","Erythrocytes -- Testing","Biomedical Engineering and Bioengineering"],"dc:title":["Red blood cell deformability testing by using a rheological method"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering Committee"],"thesis:degree_name":["Master of Science in Biomedical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:42:55Z"}