{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-3977"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-3977","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Demulsification and separation of oil in a water/particulate system","abstract":"<p>The wastewater generated from installation factories contains high suspended solids ( SS ) and oil. Effective removal of oil and clay particles in washrack wastewater can be achieved by using organic polymer TFL-398 alone or in conjunction with alum. The dissolved/emulsified oil concentration and suspended solids are used to represent the degree of oil demulsification and clay particles destabilization, respectively.</p><p>To improve the efficiency of oil demulsification and reduce the chemical consumption, pretreatment of the influent wastewater is essentially necessary. pH adjustment to 11-12 generally reduces chemical requirement. Total oil concentration was reduced significantly at pH = 11.7 without any chemical addition. At this pH value, the petroleum hydrocarbons are converted to hydrophilic compounds which can no longer be extracted with organic solvents.</p><p>Flow recycle by mixing treated wastewater and raw wastewater also reduces chemical consumption. By utilizing TFL-398 alone at pH = 11.7, and flow recycle ratio of 1.5 or greater, the polymer dose of 200 mg/l can remove 95% of oil and 99.5% of clay particles. The polymer demand can be reduced to as low as 25 mg/1 in conjuction with alum dosage of 1,000 mg/l at pH = 7.0.</p>","abstract_html":"&lt;p&gt;The wastewater generated from installation factories contains high suspended solids ( SS ) and oil. Effective removal of oil and clay particles in washrack wastewater can be achieved by using organic polymer TFL-398 alone or in conjunction with alum. The dissolved/emulsified oil concentration and suspended solids are used to represent the degree of oil demulsification and clay particles destabilization, respectively.&lt;/p&gt;&lt;p&gt;To improve the efficiency of oil demulsification and reduce the chemical consumption, pretreatment of the influent wastewater is essentially necessary. pH adjustment to 11-12 generally reduces chemical requirement. Total oil concentration was reduced significantly at pH = 11.7 without any chemical addition. At this pH value, the petroleum hydrocarbons are converted to hydrophilic compounds which can no longer be extracted with organic solvents.&lt;/p&gt;&lt;p&gt;Flow recycle by mixing treated wastewater and raw wastewater also reduces chemical consumption. By utilizing TFL-398 alone at pH = 11.7, and flow recycle ratio of 1.5 or greater, the polymer dose of 200 mg/l can remove 95% of oil and 99.5% of clay particles. The polymer demand can be reduced to as low as 25 mg/1 in conjuction with alum dosage of 1,000 mg/l at pH = 7.0.&lt;/p&gt;","abstract_has_math":false,"creators":["Tai, Fong-Jung"],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Yeun C. Wu","Paul N. Cheremisinoff"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:02Z","subjects":["Petroleum","Demulsification","Water -- Purification","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/2963","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/2963","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-3977","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yeun C. Wu","Paul N. Cheremisinoff"]},{"key":"dc:creator","label":"Author","values":["Tai, Fong-Jung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1990-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Petroleum","Demulsification","Water -- Purification","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/2963"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The wastewater generated from installation factories contains high suspended solids ( SS ) and oil. Effective removal of oil and clay particles in washrack wastewater can be achieved by using organic polymer TFL-398 alone or in conjunction with alum. The dissolved/emulsified oil concentration and suspended solids are used to represent the degree of oil demulsification and clay particles destabilization, respectively.</p><p>To improve the efficiency of oil demulsification and reduce the chemical consumption, pretreatment of the influent wastewater is essentially necessary. pH adjustment to 11-12 generally reduces chemical requirement. Total oil concentration was reduced significantly at pH = 11.7 without any chemical addition. At this pH value, the petroleum hydrocarbons are converted to hydrophilic compounds which can no longer be extracted with organic solvents.</p><p>Flow recycle by mixing treated wastewater and raw wastewater also reduces chemical consumption. By utilizing TFL-398 alone at pH = 11.7, and flow recycle ratio of 1.5 or greater, the polymer dose of 200 mg/l can remove 95% of oil and 99.5% of clay particles. The polymer demand can be reduced to as low as 25 mg/1 in conjuction with alum dosage of 1,000 mg/l at pH = 7.0.</p>"]},{"key":"dc:title","label":"Title","values":["Demulsification and separation of oil in a water/particulate system"]}]}],"canonical_facts":{"dc:contributor":["Yeun C. Wu","Paul N. Cheremisinoff"],"dc:creator":["Tai, Fong-Jung"],"dc:date.created":["1990-05-31T07:00:00Z"],"dc:description.abstract":["<p>The wastewater generated from installation factories contains high suspended solids ( SS ) and oil. Effective removal of oil and clay particles in washrack wastewater can be achieved by using organic polymer TFL-398 alone or in conjunction with alum. The dissolved/emulsified oil concentration and suspended solids are used to represent the degree of oil demulsification and clay particles destabilization, respectively.</p><p>To improve the efficiency of oil demulsification and reduce the chemical consumption, pretreatment of the influent wastewater is essentially necessary. pH adjustment to 11-12 generally reduces chemical requirement. Total oil concentration was reduced significantly at pH = 11.7 without any chemical addition. At this pH value, the petroleum hydrocarbons are converted to hydrophilic compounds which can no longer be extracted with organic solvents.</p><p>Flow recycle by mixing treated wastewater and raw wastewater also reduces chemical consumption. By utilizing TFL-398 alone at pH = 11.7, and flow recycle ratio of 1.5 or greater, the polymer dose of 200 mg/l can remove 95% of oil and 99.5% of clay particles. The polymer demand can be reduced to as low as 25 mg/1 in conjuction with alum dosage of 1,000 mg/l at pH = 7.0.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/2963"],"dc:subject":["Petroleum","Demulsification","Water -- Purification","Environmental Engineering"],"dc:title":["Demulsification and separation of oil in a water/particulate system"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:02Z"}