{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4018"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4018","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"An intelligent computerized pulse-duplicator for the in-vitro evaluation of prosthetic heart valves","abstract":"<p>A computerized data acquisition system is presented for the in-vitro determination of the hydrodynamic performance of prosthetic heart valves. High speed data acquisition and ensemble averaging techniques are employed to minimize error and provide a standard for data collection and analysis across a wide range of simulated physiologic conditions. Processing algorithms automatically divide the cardiac cycle into phases based on landmarks in the pressure and flow waveforms, with minimal variability and without operator intervention. The contributions of valve resistance, regurgitation, ejection, leakage, and power loss to hydrodynamic performance are isolated for investigation. Phasic power loss analysis is reviewed as a relative measure of valve merit, with preliminary results revealing a need for further investigation into the clinical significance of such losses.</p>","abstract_html":"&lt;p&gt;A computerized data acquisition system is presented for the in-vitro determination of the hydrodynamic performance of prosthetic heart valves. High speed data acquisition and ensemble averaging techniques are employed to minimize error and provide a standard for data collection and analysis across a wide range of simulated physiologic conditions. Processing algorithms automatically divide the cardiac cycle into phases based on landmarks in the pressure and flow waveforms, with minimal variability and without operator intervention. The contributions of valve resistance, regurgitation, ejection, leakage, and power loss to hydrodynamic performance are isolated for investigation. Phasic power loss analysis is reviewed as a relative measure of valve merit, with preliminary results revealing a need for further investigation into the clinical significance of such losses.&lt;/p&gt;","abstract_has_math":false,"creators":["Andrews, John F."],"institution":null,"degree_name":"Master of Science in Biomedical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Biomedical Engineering Committee","degree_department":null,"school":null,"contributors":["David S. Kristol","Shlomo Gabbay","Peter Engler"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:02Z","subjects":["Pulse -- Simulation methods","Heart valve prosthesis -- Testing -- Data processing","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3004","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3004","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4018","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David S. Kristol","Shlomo Gabbay","Peter Engler"]},{"key":"dc:creator","label":"Author","values":["Andrews, John F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1988-09-30T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering Committee"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Pulse -- Simulation methods","Heart valve prosthesis -- Testing -- Data processing","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3004"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A computerized data acquisition system is presented for the in-vitro determination of the hydrodynamic performance of prosthetic heart valves. High speed data acquisition and ensemble averaging techniques are employed to minimize error and provide a standard for data collection and analysis across a wide range of simulated physiologic conditions. Processing algorithms automatically divide the cardiac cycle into phases based on landmarks in the pressure and flow waveforms, with minimal variability and without operator intervention. The contributions of valve resistance, regurgitation, ejection, leakage, and power loss to hydrodynamic performance are isolated for investigation. Phasic power loss analysis is reviewed as a relative measure of valve merit, with preliminary results revealing a need for further investigation into the clinical significance of such losses.</p>"]},{"key":"dc:title","label":"Title","values":["An intelligent computerized pulse-duplicator for the in-vitro evaluation of prosthetic heart valves"]}]}],"canonical_facts":{"dc:contributor":["David S. Kristol","Shlomo Gabbay","Peter Engler"],"dc:creator":["Andrews, John F."],"dc:date.created":["1988-09-30T07:00:00Z"],"dc:description.abstract":["<p>A computerized data acquisition system is presented for the in-vitro determination of the hydrodynamic performance of prosthetic heart valves. High speed data acquisition and ensemble averaging techniques are employed to minimize error and provide a standard for data collection and analysis across a wide range of simulated physiologic conditions. Processing algorithms automatically divide the cardiac cycle into phases based on landmarks in the pressure and flow waveforms, with minimal variability and without operator intervention. The contributions of valve resistance, regurgitation, ejection, leakage, and power loss to hydrodynamic performance are isolated for investigation. Phasic power loss analysis is reviewed as a relative measure of valve merit, with preliminary results revealing a need for further investigation into the clinical significance of such losses.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3004"],"dc:subject":["Pulse -- Simulation methods","Heart valve prosthesis -- Testing -- Data processing","Biomedical Engineering and Bioengineering"],"dc:title":["An intelligent computerized pulse-duplicator for the in-vitro evaluation of prosthetic heart valves"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering Committee"],"thesis:degree_name":["Master of Science in Biomedical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:02Z"}