{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4042"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4042","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Design and processing of micromechanical sensor devices","abstract":"<p>A multi-purpose cantilever beam and microbridge accelerometer structure has been designed and fabricated in this work. This same structure with modification can be employed as a capacitive accelerometer, mechanical resonance accelerometer, and a piezoresist accelerometer. Surface microengineering processing techniques have been developed in this work. The cavity structure significantly reduced the parasitic capacitance. This work reports the first instance of spin-on glass for rnicromechanical device applications as both a sacrifical layer and a planarization material for the cavity. Other results of this thesis including:</p><p>1. LPCVD low temperature oxide as the base material from which the cavity is etched;</p><p>2. Using LPCVD polysilicon beams as bottom electrodes;</p><p>3. Using low temperature, fine grain, stress free LPCVD polysilicon beams as top electrodes or sensing elements;</p><p>4. RTA annealing for polysilicon film stress relief.</p>","abstract_html":"&lt;p&gt;A multi-purpose cantilever beam and microbridge accelerometer structure has been designed and fabricated in this work. This same structure with modification can be employed as a capacitive accelerometer, mechanical resonance accelerometer, and a piezoresist accelerometer. Surface microengineering processing techniques have been developed in this work. The cavity structure significantly reduced the parasitic capacitance. This work reports the first instance of spin-on glass for rnicromechanical device applications as both a sacrifical layer and a planarization material for the cavity. Other results of this thesis including:&lt;/p&gt;&lt;p&gt;1. LPCVD low temperature oxide as the base material from which the cavity is etched;&lt;/p&gt;&lt;p&gt;2. Using LPCVD polysilicon beams as bottom electrodes;&lt;/p&gt;&lt;p&gt;3. Using low temperature, fine grain, stress free LPCVD polysilicon beams as top electrodes or sensing elements;&lt;/p&gt;&lt;p&gt;4. RTA annealing for polysilicon film stress relief.&lt;/p&gt;","abstract_has_math":false,"creators":["Zhou, Zhixiong Joe"],"institution":null,"degree_name":"Master of Science in Electrical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["William N. Carr","Durgamadhab Misra","N. M. Ravindra"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:02Z","subjects":["Accelerometers -- Design and construction","Micromechanics","Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3028","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3028","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4042","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["William N. Carr","Durgamadhab Misra","N. M. Ravindra"]},{"key":"dc:creator","label":"Author","values":["Zhou, Zhixiong Joe"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1990-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Accelerometers -- Design and construction","Micromechanics","Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3028"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A multi-purpose cantilever beam and microbridge accelerometer structure has been designed and fabricated in this work. This same structure with modification can be employed as a capacitive accelerometer, mechanical resonance accelerometer, and a piezoresist accelerometer. Surface microengineering processing techniques have been developed in this work. The cavity structure significantly reduced the parasitic capacitance. This work reports the first instance of spin-on glass for rnicromechanical device applications as both a sacrifical layer and a planarization material for the cavity. Other results of this thesis including:</p><p>1. LPCVD low temperature oxide as the base material from which the cavity is etched;</p><p>2. Using LPCVD polysilicon beams as bottom electrodes;</p><p>3. Using low temperature, fine grain, stress free LPCVD polysilicon beams as top electrodes or sensing elements;</p><p>4. RTA annealing for polysilicon film stress relief.</p>"]},{"key":"dc:title","label":"Title","values":["Design and processing of micromechanical sensor devices"]}]}],"canonical_facts":{"dc:contributor":["William N. Carr","Durgamadhab Misra","N. M. Ravindra"],"dc:creator":["Zhou, Zhixiong Joe"],"dc:date.created":["1990-05-31T07:00:00Z"],"dc:description.abstract":["<p>A multi-purpose cantilever beam and microbridge accelerometer structure has been designed and fabricated in this work. This same structure with modification can be employed as a capacitive accelerometer, mechanical resonance accelerometer, and a piezoresist accelerometer. Surface microengineering processing techniques have been developed in this work. The cavity structure significantly reduced the parasitic capacitance. This work reports the first instance of spin-on glass for rnicromechanical device applications as both a sacrifical layer and a planarization material for the cavity. Other results of this thesis including:</p><p>1. LPCVD low temperature oxide as the base material from which the cavity is etched;</p><p>2. Using LPCVD polysilicon beams as bottom electrodes;</p><p>3. Using low temperature, fine grain, stress free LPCVD polysilicon beams as top electrodes or sensing elements;</p><p>4. RTA annealing for polysilicon film stress relief.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3028"],"dc:subject":["Accelerometers -- Design and construction","Micromechanics","Electrical and Electronics"],"dc:title":["Design and processing of micromechanical sensor devices"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science in Electrical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:02Z"}