{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4109"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4109","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Fibrin glue for spilt-thickness skin grafts and microsurgical end-to-end arterial anastomoses in live rats","abstract":"<p>Fibrinogen and thrombin were combined to make a \"glue\" for adherence in microvascular anastomoses and split-thickness autologous skin grafts in rats. The powdered human fibrinogen and bovine thrombin were mixed with sterile water and each applied drop-wise through separate syringes in equal concentrations. A gelatinous clot formed in 10 seconds, and was completely coagulated in 45 seconds. In part I, one-half of the group had their grafts sutured, and one-half had their grafts glued in place.</p><p>In part II, microvascular arterial anastomoses were performed. Group I had their arteries reanastomosed using sutures only; group II had their arteries reanastomosed by using an intraluminal stent, two stay-sutures, and the fibrin glue.</p><p>The microvascular anastomoses were almost all patent. The glue served as a hemostyptic agent as well as an adhesive. In both groups, the sutured technique took nearly twice as long as the gluing technique.</p><p>The suture material caused a foreign body reaction on the grafts, not seen in the group with glue. The glued grafts took better overall, but all grafts sloughed at 2-3 weeks post-op, mainly due to infection and hemorrhage caused by excessive motion.</p>","abstract_html":"&lt;p&gt;Fibrinogen and thrombin were combined to make a &quot;glue&quot; for adherence in microvascular anastomoses and split-thickness autologous skin grafts in rats. The powdered human fibrinogen and bovine thrombin were mixed with sterile water and each applied drop-wise through separate syringes in equal concentrations. A gelatinous clot formed in 10 seconds, and was completely coagulated in 45 seconds. In part I, one-half of the group had their grafts sutured, and one-half had their grafts glued in place.&lt;/p&gt;&lt;p&gt;In part II, microvascular arterial anastomoses were performed. Group I had their arteries reanastomosed using sutures only; group II had their arteries reanastomosed by using an intraluminal stent, two stay-sutures, and the fibrin glue.&lt;/p&gt;&lt;p&gt;The microvascular anastomoses were almost all patent. The glue served as a hemostyptic agent as well as an adhesive. In both groups, the sutured technique took nearly twice as long as the gluing technique.&lt;/p&gt;&lt;p&gt;The suture material caused a foreign body reaction on the grafts, not seen in the group with glue. The glued grafts took better overall, but all grafts sloughed at 2-3 weeks post-op, mainly due to infection and hemorrhage caused by excessive motion.&lt;/p&gt;","abstract_has_math":false,"creators":["Drastal, Susan Diane"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Biomedical Engineering Committee","degree_department":null,"school":null,"contributors":["David S. Kristol","Peter Engler","Arthur B. Ritter"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:09Z","subjects":["Fibrin","Skin-grafting","Arteriovenous anastomosis","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3095","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3095","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4109","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David S. Kristol","Peter Engler","Arthur B. Ritter"]},{"key":"dc:creator","label":"Author","values":["Drastal, Susan Diane"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1987-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering Committee"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fibrin","Skin-grafting","Arteriovenous anastomosis","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3095"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Fibrinogen and thrombin were combined to make a \"glue\" for adherence in microvascular anastomoses and split-thickness autologous skin grafts in rats. The powdered human fibrinogen and bovine thrombin were mixed with sterile water and each applied drop-wise through separate syringes in equal concentrations. A gelatinous clot formed in 10 seconds, and was completely coagulated in 45 seconds. In part I, one-half of the group had their grafts sutured, and one-half had their grafts glued in place.</p><p>In part II, microvascular arterial anastomoses were performed. Group I had their arteries reanastomosed using sutures only; group II had their arteries reanastomosed by using an intraluminal stent, two stay-sutures, and the fibrin glue.</p><p>The microvascular anastomoses were almost all patent. The glue served as a hemostyptic agent as well as an adhesive. In both groups, the sutured technique took nearly twice as long as the gluing technique.</p><p>The suture material caused a foreign body reaction on the grafts, not seen in the group with glue. The glued grafts took better overall, but all grafts sloughed at 2-3 weeks post-op, mainly due to infection and hemorrhage caused by excessive motion.</p>"]},{"key":"dc:title","label":"Title","values":["Fibrin glue for spilt-thickness skin grafts and microsurgical end-to-end arterial anastomoses in live rats"]}]}],"canonical_facts":{"dc:contributor":["David S. Kristol","Peter Engler","Arthur B. Ritter"],"dc:creator":["Drastal, Susan Diane"],"dc:date.created":["1987-05-31T07:00:00Z"],"dc:description.abstract":["<p>Fibrinogen and thrombin were combined to make a \"glue\" for adherence in microvascular anastomoses and split-thickness autologous skin grafts in rats. The powdered human fibrinogen and bovine thrombin were mixed with sterile water and each applied drop-wise through separate syringes in equal concentrations. A gelatinous clot formed in 10 seconds, and was completely coagulated in 45 seconds. In part I, one-half of the group had their grafts sutured, and one-half had their grafts glued in place.</p><p>In part II, microvascular arterial anastomoses were performed. Group I had their arteries reanastomosed using sutures only; group II had their arteries reanastomosed by using an intraluminal stent, two stay-sutures, and the fibrin glue.</p><p>The microvascular anastomoses were almost all patent. The glue served as a hemostyptic agent as well as an adhesive. In both groups, the sutured technique took nearly twice as long as the gluing technique.</p><p>The suture material caused a foreign body reaction on the grafts, not seen in the group with glue. The glued grafts took better overall, but all grafts sloughed at 2-3 weeks post-op, mainly due to infection and hemorrhage caused by excessive motion.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3095"],"dc:subject":["Fibrin","Skin-grafting","Arteriovenous anastomosis","Biomedical Engineering and Bioengineering"],"dc:title":["Fibrin glue for spilt-thickness skin grafts and microsurgical end-to-end arterial anastomoses in live rats"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering Committee"],"thesis:degree_name":["Master of Science in Biomedical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:09Z"}