{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4125"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4125","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Simulation of AIDS patient detoxification by an extracorporeal device and related experimental studies","abstract":"<p>A simple numerical simulation of an AIDS patient detoxification by an extracorporeal device for the removal of virus has been designed. The mathematical model accounts for healthy white cells (W) attacking and destroying the virus (V), while at the same time the virus attacks and infects certain white cells. The infected white cells (W<sub>i</sub>) serve as a site for viral growth, and finally the cell is lysed, releasing a large number of viruses in the blood stream. This model can be used to predict concentrations over a given period for the patient.</p><p>The device incorporates an antitwister mechanism allowing for continuous feed and collection lines to be attached directly to the rotating centrifuge head, eliminating the necessity to use a rotating seal. Experimental studies have been performed using a radial-flow centrifuge head by varying parameters such as hematocrit of feed blood, speed of centrifuge and withdrawal rate of sample. Initial studies indicate that the device is capable of separating plasma from blood cellular components on a continuous basis. Since virally infected white cells have different surface properties and densities, it is possible that under special conditions, they may be separated from other cellular components, and may provide AIDS patients with relief in the early stages of the disease and extended survival.</p>","abstract_html":"&lt;p&gt;A simple numerical simulation of an AIDS patient detoxification by an extracorporeal device for the removal of virus has been designed. The mathematical model accounts for healthy white cells (W) attacking and destroying the virus (V), while at the same time the virus attacks and infects certain white cells. The infected white cells (W&lt;sub&gt;i&lt;/sub&gt;) serve as a site for viral growth, and finally the cell is lysed, releasing a large number of viruses in the blood stream. This model can be used to predict concentrations over a given period for the patient.&lt;/p&gt;&lt;p&gt;The device incorporates an antitwister mechanism allowing for continuous feed and collection lines to be attached directly to the rotating centrifuge head, eliminating the necessity to use a rotating seal. Experimental studies have been performed using a radial-flow centrifuge head by varying parameters such as hematocrit of feed blood, speed of centrifuge and withdrawal rate of sample. Initial studies indicate that the device is capable of separating plasma from blood cellular components on a continuous basis. Since virally infected white cells have different surface properties and densities, it is possible that under special conditions, they may be separated from other cellular components, and may provide AIDS patients with relief in the early stages of the disease and extended survival.&lt;/p&gt;","abstract_has_math":false,"creators":["Kapadvanjwala, Mansoor Yusuf"],"institution":null,"degree_name":"Master of Science in Biomedical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Biomedical Engineering Committee","degree_department":null,"school":null,"contributors":["Samir S. Sofer","David S. Kristol","Arthur B. Ritter"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:09Z","subjects":["Human immunodeficiency viruses","AIDS (Disease)","Blood -- Artificial circulation","Separators (Machines)","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3111","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3111","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4125","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Samir S. Sofer","David S. Kristol","Arthur B. Ritter"]},{"key":"dc:creator","label":"Author","values":["Kapadvanjwala, Mansoor Yusuf"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1988-08-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering Committee"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Human immunodeficiency viruses","AIDS (Disease)","Blood -- Artificial circulation","Separators (Machines)","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3111"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A simple numerical simulation of an AIDS patient detoxification by an extracorporeal device for the removal of virus has been designed. The mathematical model accounts for healthy white cells (W) attacking and destroying the virus (V), while at the same time the virus attacks and infects certain white cells. The infected white cells (W<sub>i</sub>) serve as a site for viral growth, and finally the cell is lysed, releasing a large number of viruses in the blood stream. This model can be used to predict concentrations over a given period for the patient.</p><p>The device incorporates an antitwister mechanism allowing for continuous feed and collection lines to be attached directly to the rotating centrifuge head, eliminating the necessity to use a rotating seal. Experimental studies have been performed using a radial-flow centrifuge head by varying parameters such as hematocrit of feed blood, speed of centrifuge and withdrawal rate of sample. Initial studies indicate that the device is capable of separating plasma from blood cellular components on a continuous basis. Since virally infected white cells have different surface properties and densities, it is possible that under special conditions, they may be separated from other cellular components, and may provide AIDS patients with relief in the early stages of the disease and extended survival.</p>"]},{"key":"dc:title","label":"Title","values":["Simulation of AIDS patient detoxification by an extracorporeal device and related experimental studies"]}]}],"canonical_facts":{"dc:contributor":["Samir S. Sofer","David S. Kristol","Arthur B. Ritter"],"dc:creator":["Kapadvanjwala, Mansoor Yusuf"],"dc:date.created":["1988-08-31T07:00:00Z"],"dc:description.abstract":["<p>A simple numerical simulation of an AIDS patient detoxification by an extracorporeal device for the removal of virus has been designed. The mathematical model accounts for healthy white cells (W) attacking and destroying the virus (V), while at the same time the virus attacks and infects certain white cells. The infected white cells (W<sub>i</sub>) serve as a site for viral growth, and finally the cell is lysed, releasing a large number of viruses in the blood stream. This model can be used to predict concentrations over a given period for the patient.</p><p>The device incorporates an antitwister mechanism allowing for continuous feed and collection lines to be attached directly to the rotating centrifuge head, eliminating the necessity to use a rotating seal. Experimental studies have been performed using a radial-flow centrifuge head by varying parameters such as hematocrit of feed blood, speed of centrifuge and withdrawal rate of sample. Initial studies indicate that the device is capable of separating plasma from blood cellular components on a continuous basis. Since virally infected white cells have different surface properties and densities, it is possible that under special conditions, they may be separated from other cellular components, and may provide AIDS patients with relief in the early stages of the disease and extended survival.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3111"],"dc:subject":["Human immunodeficiency viruses","AIDS (Disease)","Blood -- Artificial circulation","Separators (Machines)","Biomedical Engineering and Bioengineering"],"dc:title":["Simulation of AIDS patient detoxification by an extracorporeal device and related experimental studies"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering Committee"],"thesis:degree_name":["Master of Science in Biomedical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:09Z"}