{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4229"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4229","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Seizure and wear testing methodology","abstract":"<p>In this work the seizure as an adhesive wear has been discussed and analyzed The diffusion hypotheses is accepted as the seizure mechanism. It was determined that the surface of machine components, material properties, and contact stresses in sliding and loading zone are responsible for the wear.</p><p>A computer controlled wear testing methodology has been developed and a wear testing machine has been designed and assembled. The tests for the selected gray cast non and alloy steel specimens with different surface treatment were performed on the designed wear testing machine.</p><p>The test results showed that the selected materials with additional surface treatment such as ion-nitriding, magnetic treatment, and ion-nitriding with magnetic treatment have improved the \"ear resistence and reduced the seizure failure The highest wear resistance obtained for materials is with ion-nitriding and magnetic treatment.</p>","abstract_html":"&lt;p&gt;In this work the seizure as an adhesive wear has been discussed and analyzed The diffusion hypotheses is accepted as the seizure mechanism. It was determined that the surface of machine components, material properties, and contact stresses in sliding and loading zone are responsible for the wear.&lt;/p&gt;&lt;p&gt;A computer controlled wear testing methodology has been developed and a wear testing machine has been designed and assembled. The tests for the selected gray cast non and alloy steel specimens with different surface treatment were performed on the designed wear testing machine.&lt;/p&gt;&lt;p&gt;The test results showed that the selected materials with additional surface treatment such as ion-nitriding, magnetic treatment, and ion-nitriding with magnetic treatment have improved the &quot;ear resistence and reduced the seizure failure The highest wear resistance obtained for materials is with ion-nitriding and magnetic treatment.&lt;/p&gt;","abstract_has_math":false,"creators":["Shih, I-Tsung"],"institution":null,"degree_name":"Master of Science in Mechanical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Roman Dubrovsky","Avraham Harnoy","Bernard Koplik"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:15Z","subjects":["Mechanical wear","Seizing (Metals)","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3215","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3215","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4229","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Roman Dubrovsky","Avraham Harnoy","Bernard Koplik"]},{"key":"dc:creator","label":"Author","values":["Shih, I-Tsung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1988-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical wear","Seizing (Metals)","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3215"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>In this work the seizure as an adhesive wear has been discussed and analyzed The diffusion hypotheses is accepted as the seizure mechanism. It was determined that the surface of machine components, material properties, and contact stresses in sliding and loading zone are responsible for the wear.</p><p>A computer controlled wear testing methodology has been developed and a wear testing machine has been designed and assembled. The tests for the selected gray cast non and alloy steel specimens with different surface treatment were performed on the designed wear testing machine.</p><p>The test results showed that the selected materials with additional surface treatment such as ion-nitriding, magnetic treatment, and ion-nitriding with magnetic treatment have improved the \"ear resistence and reduced the seizure failure The highest wear resistance obtained for materials is with ion-nitriding and magnetic treatment.</p>"]},{"key":"dc:title","label":"Title","values":["Seizure and wear testing methodology"]}]}],"canonical_facts":{"dc:contributor":["Roman Dubrovsky","Avraham Harnoy","Bernard Koplik"],"dc:creator":["Shih, I-Tsung"],"dc:date.created":["1988-05-31T07:00:00Z"],"dc:description.abstract":["<p>In this work the seizure as an adhesive wear has been discussed and analyzed The diffusion hypotheses is accepted as the seizure mechanism. It was determined that the surface of machine components, material properties, and contact stresses in sliding and loading zone are responsible for the wear.</p><p>A computer controlled wear testing methodology has been developed and a wear testing machine has been designed and assembled. The tests for the selected gray cast non and alloy steel specimens with different surface treatment were performed on the designed wear testing machine.</p><p>The test results showed that the selected materials with additional surface treatment such as ion-nitriding, magnetic treatment, and ion-nitriding with magnetic treatment have improved the \"ear resistence and reduced the seizure failure The highest wear resistance obtained for materials is with ion-nitriding and magnetic treatment.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3215"],"dc:subject":["Mechanical wear","Seizing (Metals)","Mechanical Engineering"],"dc:title":["Seizure and wear testing methodology"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_name":["Master of Science in Mechanical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:15Z"}