{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4253"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4253","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Investigation of the stability and response of a reboiler under condensate control","abstract":"<p>Control of heat flux by condensate throttling was investigated theoretically by frequency response analysis and experimentally on a simulated reboiler control system.</p><p>Transfer functions were derived for each component and ware used to describe the response of the experi- mental system. Experimental controller settings were in reasonable agreement with the calculated results. However, general overall control was poor because of dead time and cyclic disturbances. Experiments showed that the process contained dead time in the order of three to seven times the ultimate period (0.5 - 1.0 minutes). Several sources of disturbances prevented an accurate evaluation of stability at low load conditions. The system was definitely stable at and above the design point and was marginal at the low points only because of the characteristics of the particular equipment: The method used for determining stability was the minimum area criteria which is based on the minimum deviation from the set point for the shortest time.</p><p>The investigation showed that a number of problems existed which would interfere with the use of condensate control in commercial applications.</p>","abstract_html":"&lt;p&gt;Control of heat flux by condensate throttling was investigated theoretically by frequency response analysis and experimentally on a simulated reboiler control system.&lt;/p&gt;&lt;p&gt;Transfer functions were derived for each component and ware used to describe the response of the experi- mental system. Experimental controller settings were in reasonable agreement with the calculated results. However, general overall control was poor because of dead time and cyclic disturbances. Experiments showed that the process contained dead time in the order of three to seven times the ultimate period (0.5 - 1.0 minutes). Several sources of disturbances prevented an accurate evaluation of stability at low load conditions. The system was definitely stable at and above the design point and was marginal at the low points only because of the characteristics of the particular equipment: The method used for determining stability was the minimum area criteria which is based on the minimum deviation from the set point for the shortest time.&lt;/p&gt;&lt;p&gt;The investigation showed that a number of problems existed which would interfere with the use of condensate control in commercial applications.&lt;/p&gt;","abstract_has_math":false,"creators":["Winter, Francis Arthur"],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Herbert Dengler","C. L. Mantell","Joseph Joffe"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:36Z","subjects":["Boilers","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3239","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3239","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4253","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Herbert Dengler","C. L. Mantell","Joseph Joffe"]},{"key":"dc:creator","label":"Author","values":["Winter, Francis Arthur"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1961-06-30T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Boilers","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3239"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Control of heat flux by condensate throttling was investigated theoretically by frequency response analysis and experimentally on a simulated reboiler control system.</p><p>Transfer functions were derived for each component and ware used to describe the response of the experi- mental system. Experimental controller settings were in reasonable agreement with the calculated results. However, general overall control was poor because of dead time and cyclic disturbances. Experiments showed that the process contained dead time in the order of three to seven times the ultimate period (0.5 - 1.0 minutes). Several sources of disturbances prevented an accurate evaluation of stability at low load conditions. The system was definitely stable at and above the design point and was marginal at the low points only because of the characteristics of the particular equipment: The method used for determining stability was the minimum area criteria which is based on the minimum deviation from the set point for the shortest time.</p><p>The investigation showed that a number of problems existed which would interfere with the use of condensate control in commercial applications.</p>"]},{"key":"dc:title","label":"Title","values":["Investigation of the stability and response of a reboiler under condensate control"]}]}],"canonical_facts":{"dc:contributor":["Herbert Dengler","C. L. Mantell","Joseph Joffe"],"dc:creator":["Winter, Francis Arthur"],"dc:date.created":["1961-06-30T07:00:00Z"],"dc:description.abstract":["<p>Control of heat flux by condensate throttling was investigated theoretically by frequency response analysis and experimentally on a simulated reboiler control system.</p><p>Transfer functions were derived for each component and ware used to describe the response of the experi- mental system. Experimental controller settings were in reasonable agreement with the calculated results. However, general overall control was poor because of dead time and cyclic disturbances. Experiments showed that the process contained dead time in the order of three to seven times the ultimate period (0.5 - 1.0 minutes). Several sources of disturbances prevented an accurate evaluation of stability at low load conditions. The system was definitely stable at and above the design point and was marginal at the low points only because of the characteristics of the particular equipment: The method used for determining stability was the minimum area criteria which is based on the minimum deviation from the set point for the shortest time.</p><p>The investigation showed that a number of problems existed which would interfere with the use of condensate control in commercial applications.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3239"],"dc:subject":["Boilers","Chemical Engineering"],"dc:title":["Investigation of the stability and response of a reboiler under condensate control"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:36Z"}