{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4342"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4342","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Novel high resolution columns for gas chromatography","abstract":"<p>A study was conducted to determine if BN would be a reliable solid phase or support for open tubular capillary columns and to develop a technique for the deposition of BN on the column's inner walls. The theoretical plate results for constructed precoated BN columns demonstrated that BN can be employed as solid stationary phase, but evinces low separation characteristics due to the nature of the drawing process. The development of a simple BN precoating process was tested on various diameter capillary columns and found to provide an excellent support for highly polar liquid stationary phases. Capillary columns with a diameter of approximately 0.35 mm were tested and found to perform optimum analytical separations at the desired operational flow rate of 1.00 ml per minute. Dynamic coating of a BN precoated column with coating solution containing 20 percent by weight 1 , 2 , 3 -tr is- ( 2-cyanoethoxy) propane liquid stationary phase was sufficient to provide a column that was comparable in separation capabilites to commercially available SCOT columns.</p>","abstract_html":"&lt;p&gt;A study was conducted to determine if BN would be a reliable solid phase or support for open tubular capillary columns and to develop a technique for the deposition of BN on the column&#x27;s inner walls. The theoretical plate results for constructed precoated BN columns demonstrated that BN can be employed as solid stationary phase, but evinces low separation characteristics due to the nature of the drawing process. The development of a simple BN precoating process was tested on various diameter capillary columns and found to provide an excellent support for highly polar liquid stationary phases. Capillary columns with a diameter of approximately 0.35 mm were tested and found to perform optimum analytical separations at the desired operational flow rate of 1.00 ml per minute. Dynamic coating of a BN precoated column with coating solution containing 20 percent by weight 1 , 2 , 3 -tr is- ( 2-cyanoethoxy) propane liquid stationary phase was sufficient to provide a column that was comparable in separation capabilites to commercially available SCOT columns.&lt;/p&gt;","abstract_has_math":false,"creators":["Stout, Douglas Kenneth"],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Barbara B. Kebbekus","Richard B. Trattner"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:21Z","subjects":["Gas chromatography","Capillarity","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3318","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3318","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4342","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Barbara B. Kebbekus","Richard B. Trattner"]},{"key":"dc:creator","label":"Author","values":["Stout, Douglas Kenneth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1987-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gas chromatography","Capillarity","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3318"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A study was conducted to determine if BN would be a reliable solid phase or support for open tubular capillary columns and to develop a technique for the deposition of BN on the column's inner walls. The theoretical plate results for constructed precoated BN columns demonstrated that BN can be employed as solid stationary phase, but evinces low separation characteristics due to the nature of the drawing process. The development of a simple BN precoating process was tested on various diameter capillary columns and found to provide an excellent support for highly polar liquid stationary phases. Capillary columns with a diameter of approximately 0.35 mm were tested and found to perform optimum analytical separations at the desired operational flow rate of 1.00 ml per minute. Dynamic coating of a BN precoated column with coating solution containing 20 percent by weight 1 , 2 , 3 -tr is- ( 2-cyanoethoxy) propane liquid stationary phase was sufficient to provide a column that was comparable in separation capabilites to commercially available SCOT columns.</p>"]},{"key":"dc:title","label":"Title","values":["Novel high resolution columns for gas chromatography"]}]}],"canonical_facts":{"dc:contributor":["Barbara B. Kebbekus","Richard B. Trattner"],"dc:creator":["Stout, Douglas Kenneth"],"dc:date.created":["1987-05-31T07:00:00Z"],"dc:description.abstract":["<p>A study was conducted to determine if BN would be a reliable solid phase or support for open tubular capillary columns and to develop a technique for the deposition of BN on the column's inner walls. The theoretical plate results for constructed precoated BN columns demonstrated that BN can be employed as solid stationary phase, but evinces low separation characteristics due to the nature of the drawing process. The development of a simple BN precoating process was tested on various diameter capillary columns and found to provide an excellent support for highly polar liquid stationary phases. Capillary columns with a diameter of approximately 0.35 mm were tested and found to perform optimum analytical separations at the desired operational flow rate of 1.00 ml per minute. Dynamic coating of a BN precoated column with coating solution containing 20 percent by weight 1 , 2 , 3 -tr is- ( 2-cyanoethoxy) propane liquid stationary phase was sufficient to provide a column that was comparable in separation capabilites to commercially available SCOT columns.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3318"],"dc:subject":["Gas chromatography","Capillarity","Environmental Engineering"],"dc:title":["Novel high resolution columns for gas chromatography"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:21Z"}