{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4347"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4347","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"A new method for node ranking for voltage stability in power systems","abstract":"<p>The voltage collapse in power system is a major concern for reliable operation of these systems. In this thesis, a method is proposed to determine the load margins at load nodes (loadability limits). A good portion of the computation to obtain those margins is routinely done when solving the power flow problem, thus the computational effort is greatly reduced. The proposed method is based on the fact that when voltage collapse occurs the Jacobian matrix, that is calculated when performing power flow analysis, is singular. The relationships between the elements of the Jacobian matrix and the nodal powers are exploited to determine the nodal powers that make this matrix singular. Thus, an index that determines the nodal loadability limit is calculated at every bus. This index is used to rank load nodes in terms of their proximity to the load limit that the system can provide these nodes.</p> <p>The proposed method is tested using the IEEE 14-bus and the 30-bus test systems.</p>","abstract_html":"&lt;p&gt;The voltage collapse in power system is a major concern for reliable operation of these systems. In this thesis, a method is proposed to determine the load margins at load nodes (loadability limits). A good portion of the computation to obtain those margins is routinely done when solving the power flow problem, thus the computational effort is greatly reduced. The proposed method is based on the fact that when voltage collapse occurs the Jacobian matrix, that is calculated when performing power flow analysis, is singular. The relationships between the elements of the Jacobian matrix and the nodal powers are exploited to determine the nodal powers that make this matrix singular. Thus, an index that determines the nodal loadability limit is calculated at every bus. This index is used to rank load nodes in terms of their proximity to the load limit that the system can provide these nodes.&lt;/p&gt; &lt;p&gt;The proposed method is tested using the IEEE 14-bus and the 30-bus test systems.&lt;/p&gt;","abstract_has_math":false,"creators":["Li, Hongxiang"],"institution":null,"degree_name":"Master of Science in Power and Energy Systems - (M.S.)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Walid Hubbi","Edip Niver","Marek Sosnowski"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:21Z","subjects":["Load margins","Power flow","Voltage collapse","Power and Energy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3323","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3323","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4347","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Walid Hubbi","Edip Niver","Marek Sosnowski"]},{"key":"dc:creator","label":"Author","values":["Li, Hongxiang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2012-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Power and Energy Systems - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Load margins","Power flow","Voltage collapse","Power and Energy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3323"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The voltage collapse in power system is a major concern for reliable operation of these systems. In this thesis, a method is proposed to determine the load margins at load nodes (loadability limits). A good portion of the computation to obtain those margins is routinely done when solving the power flow problem, thus the computational effort is greatly reduced. The proposed method is based on the fact that when voltage collapse occurs the Jacobian matrix, that is calculated when performing power flow analysis, is singular. The relationships between the elements of the Jacobian matrix and the nodal powers are exploited to determine the nodal powers that make this matrix singular. Thus, an index that determines the nodal loadability limit is calculated at every bus. This index is used to rank load nodes in terms of their proximity to the load limit that the system can provide these nodes.</p> <p>The proposed method is tested using the IEEE 14-bus and the 30-bus test systems.</p>"]},{"key":"dc:title","label":"Title","values":["A new method for node ranking for voltage stability in power systems"]}]}],"canonical_facts":{"dc:contributor":["Walid Hubbi","Edip Niver","Marek Sosnowski"],"dc:creator":["Li, Hongxiang"],"dc:date.created":["2012-01-31T08:00:00Z"],"dc:description.abstract":["<p>The voltage collapse in power system is a major concern for reliable operation of these systems. In this thesis, a method is proposed to determine the load margins at load nodes (loadability limits). A good portion of the computation to obtain those margins is routinely done when solving the power flow problem, thus the computational effort is greatly reduced. The proposed method is based on the fact that when voltage collapse occurs the Jacobian matrix, that is calculated when performing power flow analysis, is singular. The relationships between the elements of the Jacobian matrix and the nodal powers are exploited to determine the nodal powers that make this matrix singular. Thus, an index that determines the nodal loadability limit is calculated at every bus. This index is used to rank load nodes in terms of their proximity to the load limit that the system can provide these nodes.</p> <p>The proposed method is tested using the IEEE 14-bus and the 30-bus test systems.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3323"],"dc:subject":["Load margins","Power flow","Voltage collapse","Power and Energy"],"dc:title":["A new method for node ranking for voltage stability in power systems"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science in Power and Energy Systems - (M.S.)"]},"updated_at":"2026-11-19T08:43:21Z"}