{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4379"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4379","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Volatile organic pollutant levels in indoor environments from the use of kerosene heaters","abstract":"<p>The indoor air pollutant levels caused by use of kerosene stoves as sources of heat in residences is of increasing concern as the use of such heaters becomes more widespread. Emission of volatile organic. species (aliphatic hydrocarbons from hexane to dodecane, cyclohexane and aromatic species including benzene, toluene, ethyl benzene, m/p xylenes, o-xylene and styrene) from these devices were measured at different sites. The organic vapor samples have been collected by adsorption on Tenax GC, and quantitatively analyzed by thermal desorption into a high Resolution capillary column gas chromatograph. Mass spectral analysis was also conducted for qualitative identification of sample components. Levels of total organic pollutants have also been measured using a total hydrocarbon analyzer. Comparisons of contaminants level when the heaters are in use and when they have not been used for several days are presented. The studies show that after the heater was turned on concentrations of specific hydrocarbons, both aromatic and alkane increased (on the average)of 100 to 2000%. Room levels of total hydrocarbon increased by 900 to 1750 ppb<sub>v</sub> depending on room size and ventilation rate.</p>","abstract_html":"&lt;p&gt;The indoor air pollutant levels caused by use of kerosene stoves as sources of heat in residences is of increasing concern as the use of such heaters becomes more widespread. Emission of volatile organic. species (aliphatic hydrocarbons from hexane to dodecane, cyclohexane and aromatic species including benzene, toluene, ethyl benzene, m/p xylenes, o-xylene and styrene) from these devices were measured at different sites. The organic vapor samples have been collected by adsorption on Tenax GC, and quantitatively analyzed by thermal desorption into a high Resolution capillary column gas chromatograph. Mass spectral analysis was also conducted for qualitative identification of sample components. Levels of total organic pollutants have also been measured using a total hydrocarbon analyzer. Comparisons of contaminants level when the heaters are in use and when they have not been used for several days are presented. The studies show that after the heater was turned on concentrations of specific hydrocarbons, both aromatic and alkane increased (on the average)of 100 to 2000%. Room levels of total hydrocarbon increased by 900 to 1750 ppb&lt;sub&gt;v&lt;/sub&gt; depending on room size and ventilation rate.&lt;/p&gt;","abstract_has_math":false,"creators":["Banerjee, Kashinath"],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Joseph W. Bozzelli","James M. Grow","John W. Liskowitz"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:28Z","subjects":["Indoor air pollution","Kerosene -- Environmental aspects","Space heaters -- Environmental aspects","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3355","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3355","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4379","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Joseph W. Bozzelli","James M. Grow","John W. Liskowitz"]},{"key":"dc:creator","label":"Author","values":["Banerjee, Kashinath"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1984-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Indoor air pollution","Kerosene -- Environmental aspects","Space heaters -- Environmental aspects","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3355"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The indoor air pollutant levels caused by use of kerosene stoves as sources of heat in residences is of increasing concern as the use of such heaters becomes more widespread. Emission of volatile organic. species (aliphatic hydrocarbons from hexane to dodecane, cyclohexane and aromatic species including benzene, toluene, ethyl benzene, m/p xylenes, o-xylene and styrene) from these devices were measured at different sites. The organic vapor samples have been collected by adsorption on Tenax GC, and quantitatively analyzed by thermal desorption into a high Resolution capillary column gas chromatograph. Mass spectral analysis was also conducted for qualitative identification of sample components. Levels of total organic pollutants have also been measured using a total hydrocarbon analyzer. Comparisons of contaminants level when the heaters are in use and when they have not been used for several days are presented. The studies show that after the heater was turned on concentrations of specific hydrocarbons, both aromatic and alkane increased (on the average)of 100 to 2000%. Room levels of total hydrocarbon increased by 900 to 1750 ppb<sub>v</sub> depending on room size and ventilation rate.</p>"]},{"key":"dc:title","label":"Title","values":["Volatile organic pollutant levels in indoor environments from the use of kerosene heaters"]}]}],"canonical_facts":{"dc:contributor":["Joseph W. Bozzelli","James M. Grow","John W. Liskowitz"],"dc:creator":["Banerjee, Kashinath"],"dc:date.created":["1984-05-31T07:00:00Z"],"dc:description.abstract":["<p>The indoor air pollutant levels caused by use of kerosene stoves as sources of heat in residences is of increasing concern as the use of such heaters becomes more widespread. Emission of volatile organic. species (aliphatic hydrocarbons from hexane to dodecane, cyclohexane and aromatic species including benzene, toluene, ethyl benzene, m/p xylenes, o-xylene and styrene) from these devices were measured at different sites. The organic vapor samples have been collected by adsorption on Tenax GC, and quantitatively analyzed by thermal desorption into a high Resolution capillary column gas chromatograph. Mass spectral analysis was also conducted for qualitative identification of sample components. Levels of total organic pollutants have also been measured using a total hydrocarbon analyzer. Comparisons of contaminants level when the heaters are in use and when they have not been used for several days are presented. The studies show that after the heater was turned on concentrations of specific hydrocarbons, both aromatic and alkane increased (on the average)of 100 to 2000%. Room levels of total hydrocarbon increased by 900 to 1750 ppb<sub>v</sub> depending on room size and ventilation rate.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3355"],"dc:subject":["Indoor air pollution","Kerosene -- Environmental aspects","Space heaters -- Environmental aspects","Environmental Engineering"],"dc:title":["Volatile organic pollutant levels in indoor environments from the use of kerosene heaters"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:28Z"}