{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4393"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4393","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Saturated hydraulic conductivity of Brunswick soil with aqueous benzene solution","abstract":"<p>Tests measuring saturated hydraulic conductivity and dispersivity were conducted on Brunswick soil using an aqueous solution of benzene. The tests were performed using a flexible wall permeameter which was modified to allow extraction of effluent samples immediately upon exit of the test specimen. Influent and effluent samples were analyzed with a gas chromatograph in order to quantify dispersion and sorption in the specimen.</p><p>The test was performed using a confining pressure of 70 psi. and a hydraulic gradient of 100.3. Using a sample statically compacted to 99.2% of the Modified Proctor maximum density and tap water as a permeant, stable saturated hydraulic conductivity of 3.2 x 10<sup>-8</sup> cm/s was obtained.</p><p>The permeant was changed to 500 mg/1 benzene and introduced into the permeameter. Owing to evaporative losses in the system, the actual influent permeant concentration in the sample ranged from 55 mg/1 to 335 mg/l. Tests were conducted with aqueous benzene solution permeants for 82 days.</p><p>A significant trend observed was a gradual decline in the saturated hydraulic conductivity from 3.8 x 10<sup>-8</sup> cm/s to 3.1 x 10<sup>-8</sup> cm/s from day 25 to the end of testing (day 82). This decreasing trend corresponded with a gradual increasing effluent concentration from 40 mg/1 to 125 mg/l. An inverse relationship is therefore indicated between the saturated hydraulic conductivity and the permeant concentration for this concentration range.</p><p>A mass balance was performed which showed that 11.4 mg of benzene per pore volume is unaccounted for in the effluent. Sorption and dispersion calculations indicated that approximately 373 meq/g of benzene is sorbed to the sample and 0.0001093 cm<sup>2/<sup>/s is the coefficient of longitudinal dispersion.</p><p>Additional research is necessary using standardized test procedures to more fully quantify the interactions between Brunswick soil and benzene solutions.</p>","abstract_html":"&lt;p&gt;Tests measuring saturated hydraulic conductivity and dispersivity were conducted on Brunswick soil using an aqueous solution of benzene. The tests were performed using a flexible wall permeameter which was modified to allow extraction of effluent samples immediately upon exit of the test specimen. Influent and effluent samples were analyzed with a gas chromatograph in order to quantify dispersion and sorption in the specimen.&lt;/p&gt;&lt;p&gt;The test was performed using a confining pressure of 70 psi. and a hydraulic gradient of 100.3. Using a sample statically compacted to 99.2% of the Modified Proctor maximum density and tap water as a permeant, stable saturated hydraulic conductivity of 3.2 x 10&lt;sup&gt;-8&lt;/sup&gt; cm/s was obtained.&lt;/p&gt;&lt;p&gt;The permeant was changed to 500 mg/1 benzene and introduced into the permeameter. Owing to evaporative losses in the system, the actual influent permeant concentration in the sample ranged from 55 mg/1 to 335 mg/l. Tests were conducted with aqueous benzene solution permeants for 82 days.&lt;/p&gt;&lt;p&gt;A significant trend observed was a gradual decline in the saturated hydraulic conductivity from 3.8 x 10&lt;sup&gt;-8&lt;/sup&gt; cm/s to 3.1 x 10&lt;sup&gt;-8&lt;/sup&gt; cm/s from day 25 to the end of testing (day 82). This decreasing trend corresponded with a gradual increasing effluent concentration from 40 mg/1 to 125 mg/l. An inverse relationship is therefore indicated between the saturated hydraulic conductivity and the permeant concentration for this concentration range.&lt;/p&gt;&lt;p&gt;A mass balance was performed which showed that 11.4 mg of benzene per pore volume is unaccounted for in the effluent. Sorption and dispersion calculations indicated that approximately 373 meq/g of benzene is sorbed to the sample and 0.0001093 cm&lt;sup&gt;2/&lt;sup&gt;/s is the coefficient of longitudinal dispersion.&lt;/p&gt;&lt;p&gt;Additional research is necessary using standardized test procedures to more fully quantify the interactions between Brunswick soil and benzene solutions.&lt;/p&gt;","abstract_has_math":false,"creators":["Pisciotta, Thomas R."],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["John R. Schuring","Dorairaja Raghu","Paul N. Cheremisinoff"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:55Z","subjects":["Soil permeability","Benzene","Environmental Engineering","Toxicology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3369","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3369","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4393","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["John R. Schuring","Dorairaja Raghu","Paul N. Cheremisinoff"]},{"key":"dc:creator","label":"Author","values":["Pisciotta, Thomas R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1986-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Soil permeability","Benzene","Environmental Engineering","Toxicology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3369"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Tests measuring saturated hydraulic conductivity and dispersivity were conducted on Brunswick soil using an aqueous solution of benzene. The tests were performed using a flexible wall permeameter which was modified to allow extraction of effluent samples immediately upon exit of the test specimen. Influent and effluent samples were analyzed with a gas chromatograph in order to quantify dispersion and sorption in the specimen.</p><p>The test was performed using a confining pressure of 70 psi. and a hydraulic gradient of 100.3. Using a sample statically compacted to 99.2% of the Modified Proctor maximum density and tap water as a permeant, stable saturated hydraulic conductivity of 3.2 x 10<sup>-8</sup> cm/s was obtained.</p><p>The permeant was changed to 500 mg/1 benzene and introduced into the permeameter. Owing to evaporative losses in the system, the actual influent permeant concentration in the sample ranged from 55 mg/1 to 335 mg/l. Tests were conducted with aqueous benzene solution permeants for 82 days.</p><p>A significant trend observed was a gradual decline in the saturated hydraulic conductivity from 3.8 x 10<sup>-8</sup> cm/s to 3.1 x 10<sup>-8</sup> cm/s from day 25 to the end of testing (day 82). This decreasing trend corresponded with a gradual increasing effluent concentration from 40 mg/1 to 125 mg/l. An inverse relationship is therefore indicated between the saturated hydraulic conductivity and the permeant concentration for this concentration range.</p><p>A mass balance was performed which showed that 11.4 mg of benzene per pore volume is unaccounted for in the effluent. Sorption and dispersion calculations indicated that approximately 373 meq/g of benzene is sorbed to the sample and 0.0001093 cm<sup>2/<sup>/s is the coefficient of longitudinal dispersion.</p><p>Additional research is necessary using standardized test procedures to more fully quantify the interactions between Brunswick soil and benzene solutions.</p>"]},{"key":"dc:title","label":"Title","values":["Saturated hydraulic conductivity of Brunswick soil with aqueous benzene solution"]}]}],"canonical_facts":{"dc:contributor":["John R. Schuring","Dorairaja Raghu","Paul N. Cheremisinoff"],"dc:creator":["Pisciotta, Thomas R."],"dc:date.created":["1986-01-31T08:00:00Z"],"dc:description.abstract":["<p>Tests measuring saturated hydraulic conductivity and dispersivity were conducted on Brunswick soil using an aqueous solution of benzene. The tests were performed using a flexible wall permeameter which was modified to allow extraction of effluent samples immediately upon exit of the test specimen. Influent and effluent samples were analyzed with a gas chromatograph in order to quantify dispersion and sorption in the specimen.</p><p>The test was performed using a confining pressure of 70 psi. and a hydraulic gradient of 100.3. Using a sample statically compacted to 99.2% of the Modified Proctor maximum density and tap water as a permeant, stable saturated hydraulic conductivity of 3.2 x 10<sup>-8</sup> cm/s was obtained.</p><p>The permeant was changed to 500 mg/1 benzene and introduced into the permeameter. Owing to evaporative losses in the system, the actual influent permeant concentration in the sample ranged from 55 mg/1 to 335 mg/l. Tests were conducted with aqueous benzene solution permeants for 82 days.</p><p>A significant trend observed was a gradual decline in the saturated hydraulic conductivity from 3.8 x 10<sup>-8</sup> cm/s to 3.1 x 10<sup>-8</sup> cm/s from day 25 to the end of testing (day 82). This decreasing trend corresponded with a gradual increasing effluent concentration from 40 mg/1 to 125 mg/l. An inverse relationship is therefore indicated between the saturated hydraulic conductivity and the permeant concentration for this concentration range.</p><p>A mass balance was performed which showed that 11.4 mg of benzene per pore volume is unaccounted for in the effluent. Sorption and dispersion calculations indicated that approximately 373 meq/g of benzene is sorbed to the sample and 0.0001093 cm<sup>2/<sup>/s is the coefficient of longitudinal dispersion.</p><p>Additional research is necessary using standardized test procedures to more fully quantify the interactions between Brunswick soil and benzene solutions.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3369"],"dc:subject":["Soil permeability","Benzene","Environmental Engineering","Toxicology"],"dc:title":["Saturated hydraulic conductivity of Brunswick soil with aqueous benzene solution"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:55Z"}