{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4397"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4397","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Finite element analysis of the prosthetic acetabular region","abstract":"<p>Femoral component loosening and prosthetic stem fractures have renewed interest in conservative alternatives to conventional total hip replacements. The objective in this study is to get interfacial stresses of a acetabular surface replacement cup. This is done by performing finite element analysis of the model. A solid three - dimensional model with a grid of 3D isoparametric solid elements is generated using ANSYS, a powerful finite element analysis package. The stiffness is considered to be linearly proportional to the stress in the acetabular region. The stresses are determined by performing iterative finite element analysis. Stresses arp computed using two different prosthetic cups to allow comparison of the interfacial stresses, resulting from the use of a metal(Cobalt, Chromium and Molybednum alloy) backed polyethulene(UHMWPE) and a plain polyethylene cup without metal backing. Since the peak loads for ascending stairs were higher, these loads were used for analysis. The comparative study of the two types of cups reveals that stress distribution due to metal backed cup is more uniformly distributed and thus more desirable.</p>","abstract_html":"&lt;p&gt;Femoral component loosening and prosthetic stem fractures have renewed interest in conservative alternatives to conventional total hip replacements. The objective in this study is to get interfacial stresses of a acetabular surface replacement cup. This is done by performing finite element analysis of the model. A solid three - dimensional model with a grid of 3D isoparametric solid elements is generated using ANSYS, a powerful finite element analysis package. The stiffness is considered to be linearly proportional to the stress in the acetabular region. The stresses are determined by performing iterative finite element analysis. Stresses arp computed using two different prosthetic cups to allow comparison of the interfacial stresses, resulting from the use of a metal(Cobalt, Chromium and Molybednum alloy) backed polyethulene(UHMWPE) and a plain polyethylene cup without metal backing. Since the peak loads for ascending stairs were higher, these loads were used for analysis. The comparative study of the two types of cups reveals that stress distribution due to metal backed cup is more uniformly distributed and thus more desirable.&lt;/p&gt;","abstract_has_math":false,"creators":["Reddy, Katkuri Venkat Rammanohar"],"institution":null,"degree_name":"Master of Science in Mechanical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Michael Pappas","Harry Herman","Bernard Koplik"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:55Z","subjects":["Artificial hip joints -- Mathematical models","Finite element method","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3373","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3373","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4397","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Michael Pappas","Harry Herman","Bernard Koplik"]},{"key":"dc:creator","label":"Author","values":["Reddy, Katkuri Venkat Rammanohar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1986-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Artificial hip joints -- Mathematical models","Finite element method","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3373"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Femoral component loosening and prosthetic stem fractures have renewed interest in conservative alternatives to conventional total hip replacements. The objective in this study is to get interfacial stresses of a acetabular surface replacement cup. This is done by performing finite element analysis of the model. A solid three - dimensional model with a grid of 3D isoparametric solid elements is generated using ANSYS, a powerful finite element analysis package. The stiffness is considered to be linearly proportional to the stress in the acetabular region. The stresses are determined by performing iterative finite element analysis. Stresses arp computed using two different prosthetic cups to allow comparison of the interfacial stresses, resulting from the use of a metal(Cobalt, Chromium and Molybednum alloy) backed polyethulene(UHMWPE) and a plain polyethylene cup without metal backing. Since the peak loads for ascending stairs were higher, these loads were used for analysis. The comparative study of the two types of cups reveals that stress distribution due to metal backed cup is more uniformly distributed and thus more desirable.</p>"]},{"key":"dc:title","label":"Title","values":["Finite element analysis of the prosthetic acetabular region"]}]}],"canonical_facts":{"dc:contributor":["Michael Pappas","Harry Herman","Bernard Koplik"],"dc:creator":["Reddy, Katkuri Venkat Rammanohar"],"dc:date.created":["1986-01-31T08:00:00Z"],"dc:description.abstract":["<p>Femoral component loosening and prosthetic stem fractures have renewed interest in conservative alternatives to conventional total hip replacements. The objective in this study is to get interfacial stresses of a acetabular surface replacement cup. This is done by performing finite element analysis of the model. A solid three - dimensional model with a grid of 3D isoparametric solid elements is generated using ANSYS, a powerful finite element analysis package. The stiffness is considered to be linearly proportional to the stress in the acetabular region. The stresses are determined by performing iterative finite element analysis. Stresses arp computed using two different prosthetic cups to allow comparison of the interfacial stresses, resulting from the use of a metal(Cobalt, Chromium and Molybednum alloy) backed polyethulene(UHMWPE) and a plain polyethylene cup without metal backing. Since the peak loads for ascending stairs were higher, these loads were used for analysis. The comparative study of the two types of cups reveals that stress distribution due to metal backed cup is more uniformly distributed and thus more desirable.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3373"],"dc:subject":["Artificial hip joints -- Mathematical models","Finite element method","Mechanical Engineering"],"dc:title":["Finite element analysis of the prosthetic acetabular region"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_name":["Master of Science in Mechanical Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:55Z"}