{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4436"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4436","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Investigation of water-binding properties of industrial sludges using thermal analysis as a monitoring tool","abstract":"<p>As part of a program to develop new and more cost-effective dewatering approaches for industrial hazardous wastes, sludges and synthetic \"model\" materials were analyzed by thermal methods in an attempt to comprehend their water-binding qualities and differentiate free and bound water. These thermal methods included Differential Thermal Analysis (DTA), Thermogravimetric Analysis (TG), and Differential Scanning Calorimetry (DSC). Industrial sludges and laboratory models were compared using both standard heating techniques and subambient cooling (to -60Â°C). This latter technique provides direct indication of the amount of free water. This information can be very useful in evaluating and improving dewatering techniques for industrial hazardous sludges since waters of different binding strengths are removed with varying degrees of ease.</p><p>Based on the limited number of samples investigated, it appears that at least with certain sludges, the differentiation of free and bound water can be made by these techniques. The sludges examined have a ratio of bound water to total water, (i.e., the fraction of total water that is considered bound) ranging from 10 to 100%, averaging 50%. These results suggest that investigation of bound versus free water in any industrial sludge could be a worthwhile part of any sludge dewatering program.</p>","abstract_html":"&lt;p&gt;As part of a program to develop new and more cost-effective dewatering approaches for industrial hazardous wastes, sludges and synthetic &quot;model&quot; materials were analyzed by thermal methods in an attempt to comprehend their water-binding qualities and differentiate free and bound water. These thermal methods included Differential Thermal Analysis (DTA), Thermogravimetric Analysis (TG), and Differential Scanning Calorimetry (DSC). Industrial sludges and laboratory models were compared using both standard heating techniques and subambient cooling (to -60Â°C). This latter technique provides direct indication of the amount of free water. This information can be very useful in evaluating and improving dewatering techniques for industrial hazardous sludges since waters of different binding strengths are removed with varying degrees of ease.&lt;/p&gt;&lt;p&gt;Based on the limited number of samples investigated, it appears that at least with certain sludges, the differentiation of free and bound water can be made by these techniques. The sludges examined have a ratio of bound water to total water, (i.e., the fraction of total water that is considered bound) ranging from 10 to 100%, averaging 50%. These results suggest that investigation of bound versus free water in any industrial sludge could be a worthwhile part of any sludge dewatering program.&lt;/p&gt;","abstract_has_math":false,"creators":["Josephson, Ron"],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Paul N. Cheremisinoff","Su Ling Cheng","John W. Liskowitz"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:55Z","subjects":["Hazardous wastes","Factory and trade waste","Sewage sludge","Environmental Engineering","Toxicology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3412","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3412","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4436","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Paul N. Cheremisinoff","Su Ling Cheng","John W. Liskowitz"]},{"key":"dc:creator","label":"Author","values":["Josephson, Ron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1986-08-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hazardous wastes","Factory and trade waste","Sewage sludge","Environmental Engineering","Toxicology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3412"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>As part of a program to develop new and more cost-effective dewatering approaches for industrial hazardous wastes, sludges and synthetic \"model\" materials were analyzed by thermal methods in an attempt to comprehend their water-binding qualities and differentiate free and bound water. These thermal methods included Differential Thermal Analysis (DTA), Thermogravimetric Analysis (TG), and Differential Scanning Calorimetry (DSC). Industrial sludges and laboratory models were compared using both standard heating techniques and subambient cooling (to -60Â°C). This latter technique provides direct indication of the amount of free water. This information can be very useful in evaluating and improving dewatering techniques for industrial hazardous sludges since waters of different binding strengths are removed with varying degrees of ease.</p><p>Based on the limited number of samples investigated, it appears that at least with certain sludges, the differentiation of free and bound water can be made by these techniques. The sludges examined have a ratio of bound water to total water, (i.e., the fraction of total water that is considered bound) ranging from 10 to 100%, averaging 50%. These results suggest that investigation of bound versus free water in any industrial sludge could be a worthwhile part of any sludge dewatering program.</p>"]},{"key":"dc:title","label":"Title","values":["Investigation of water-binding properties of industrial sludges using thermal analysis as a monitoring tool"]}]}],"canonical_facts":{"dc:contributor":["Paul N. Cheremisinoff","Su Ling Cheng","John W. Liskowitz"],"dc:creator":["Josephson, Ron"],"dc:date.created":["1986-08-31T07:00:00Z"],"dc:description.abstract":["<p>As part of a program to develop new and more cost-effective dewatering approaches for industrial hazardous wastes, sludges and synthetic \"model\" materials were analyzed by thermal methods in an attempt to comprehend their water-binding qualities and differentiate free and bound water. These thermal methods included Differential Thermal Analysis (DTA), Thermogravimetric Analysis (TG), and Differential Scanning Calorimetry (DSC). Industrial sludges and laboratory models were compared using both standard heating techniques and subambient cooling (to -60Â°C). This latter technique provides direct indication of the amount of free water. This information can be very useful in evaluating and improving dewatering techniques for industrial hazardous sludges since waters of different binding strengths are removed with varying degrees of ease.</p><p>Based on the limited number of samples investigated, it appears that at least with certain sludges, the differentiation of free and bound water can be made by these techniques. The sludges examined have a ratio of bound water to total water, (i.e., the fraction of total water that is considered bound) ranging from 10 to 100%, averaging 50%. These results suggest that investigation of bound versus free water in any industrial sludge could be a worthwhile part of any sludge dewatering program.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3412"],"dc:subject":["Hazardous wastes","Factory and trade waste","Sewage sludge","Environmental Engineering","Toxicology"],"dc:title":["Investigation of water-binding properties of industrial sludges using thermal analysis as a monitoring tool"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:55Z"}