{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4457"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4457","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Air pollutant emissions from non-vented radiant kerosene heater","abstract":"<p>Gaseous emissions from non-vented kerosene heaters can generate and create significant indoor air concentrations of various gaseous pollutants. Indoor air concentrations resulting from operating a portable non-vented radiant type kerosene heater in three rooms of size 38.7, 58.1 and 137 M<sup>3</sup> were studied. Studies in the environmental chamber having a size of 38.7 M<sup>3</sup> under two sets of ventilation conditions showed elevated levels of CO<sub>2</sub>, total hydrocarbons and CO. An emission rate model was used to estimate the strength of pollutant source, for total hydrocarbons, CO<sub>2</sub> and CO with data reported in terms of mass of pollutant emitted per unit weight of kerosene used. Two phases of CO<sub>2</sub> emissions have been observed and based on this, a general equation for CO<sub>2</sub> emission rate has been developed which includes the total duration of heater operation.</p><p>S/VCO<sub><sub>2</sub></sub> = 425/T + 1350 mg/g of kerosene used. ( T = duration of heater operation)</p><p>S/V<sub>THC</sub> = 0.18 +/- 0.03 mg/g of kerosene used.</p><p>S/V<sub>CO</sub> = 5.9 +/- 1.25 mg/g of kerosene used.</p><p>S/V is the emission rate of polluant in mq/g.The effect of mixing on the concentration profile of pollutant has also been studied.</p>","abstract_html":"&lt;p&gt;Gaseous emissions from non-vented kerosene heaters can generate and create significant indoor air concentrations of various gaseous pollutants. Indoor air concentrations resulting from operating a portable non-vented radiant type kerosene heater in three rooms of size 38.7, 58.1 and 137 M&lt;sup&gt;3&lt;/sup&gt; were studied. Studies in the environmental chamber having a size of 38.7 M&lt;sup&gt;3&lt;/sup&gt; under two sets of ventilation conditions showed elevated levels of CO&lt;sub&gt;2&lt;/sub&gt;, total hydrocarbons and CO. An emission rate model was used to estimate the strength of pollutant source, for total hydrocarbons, CO&lt;sub&gt;2&lt;/sub&gt; and CO with data reported in terms of mass of pollutant emitted per unit weight of kerosene used. Two phases of CO&lt;sub&gt;2&lt;/sub&gt; emissions have been observed and based on this, a general equation for CO&lt;sub&gt;2&lt;/sub&gt; emission rate has been developed which includes the total duration of heater operation.&lt;/p&gt;&lt;p&gt;S/VCO&lt;sub&gt;&lt;sub&gt;2&lt;/sub&gt;&lt;/sub&gt; = 425/T + 1350 mg/g of kerosene used. ( T = duration of heater operation)&lt;/p&gt;&lt;p&gt;S/V&lt;sub&gt;THC&lt;/sub&gt; = 0.18 +/- 0.03 mg/g of kerosene used.&lt;/p&gt;&lt;p&gt;S/V&lt;sub&gt;CO&lt;/sub&gt; = 5.9 +/- 1.25 mg/g of kerosene used.&lt;/p&gt;&lt;p&gt;S/V is the emission rate of polluant in mq/g.The effect of mixing on the concentration profile of pollutant has also been studied.&lt;/p&gt;","abstract_has_math":false,"creators":["Mishra, Anil Kumar"],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Joseph W. Bozzelli","Barbara B. Kebbekus"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:43:55Z","subjects":["Kerosene heaters","Air -- Pollution","Pollutants","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3433","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3433","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4457","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Joseph W. Bozzelli","Barbara B. Kebbekus"]},{"key":"dc:creator","label":"Author","values":["Mishra, Anil Kumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1986-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Kerosene heaters","Air -- Pollution","Pollutants","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3433"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Gaseous emissions from non-vented kerosene heaters can generate and create significant indoor air concentrations of various gaseous pollutants. Indoor air concentrations resulting from operating a portable non-vented radiant type kerosene heater in three rooms of size 38.7, 58.1 and 137 M<sup>3</sup> were studied. Studies in the environmental chamber having a size of 38.7 M<sup>3</sup> under two sets of ventilation conditions showed elevated levels of CO<sub>2</sub>, total hydrocarbons and CO. An emission rate model was used to estimate the strength of pollutant source, for total hydrocarbons, CO<sub>2</sub> and CO with data reported in terms of mass of pollutant emitted per unit weight of kerosene used. Two phases of CO<sub>2</sub> emissions have been observed and based on this, a general equation for CO<sub>2</sub> emission rate has been developed which includes the total duration of heater operation.</p><p>S/VCO<sub><sub>2</sub></sub> = 425/T + 1350 mg/g of kerosene used. ( T = duration of heater operation)</p><p>S/V<sub>THC</sub> = 0.18 +/- 0.03 mg/g of kerosene used.</p><p>S/V<sub>CO</sub> = 5.9 +/- 1.25 mg/g of kerosene used.</p><p>S/V is the emission rate of polluant in mq/g.The effect of mixing on the concentration profile of pollutant has also been studied.</p>"]},{"key":"dc:title","label":"Title","values":["Air pollutant emissions from non-vented radiant kerosene heater"]}]}],"canonical_facts":{"dc:contributor":["Joseph W. Bozzelli","Barbara B. Kebbekus"],"dc:creator":["Mishra, Anil Kumar"],"dc:date.created":["1986-05-31T07:00:00Z"],"dc:description.abstract":["<p>Gaseous emissions from non-vented kerosene heaters can generate and create significant indoor air concentrations of various gaseous pollutants. Indoor air concentrations resulting from operating a portable non-vented radiant type kerosene heater in three rooms of size 38.7, 58.1 and 137 M<sup>3</sup> were studied. Studies in the environmental chamber having a size of 38.7 M<sup>3</sup> under two sets of ventilation conditions showed elevated levels of CO<sub>2</sub>, total hydrocarbons and CO. An emission rate model was used to estimate the strength of pollutant source, for total hydrocarbons, CO<sub>2</sub> and CO with data reported in terms of mass of pollutant emitted per unit weight of kerosene used. Two phases of CO<sub>2</sub> emissions have been observed and based on this, a general equation for CO<sub>2</sub> emission rate has been developed which includes the total duration of heater operation.</p><p>S/VCO<sub><sub>2</sub></sub> = 425/T + 1350 mg/g of kerosene used. ( T = duration of heater operation)</p><p>S/V<sub>THC</sub> = 0.18 +/- 0.03 mg/g of kerosene used.</p><p>S/V<sub>CO</sub> = 5.9 +/- 1.25 mg/g of kerosene used.</p><p>S/V is the emission rate of polluant in mq/g.The effect of mixing on the concentration profile of pollutant has also been studied.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3433"],"dc:subject":["Kerosene heaters","Air -- Pollution","Pollutants","Environmental Engineering"],"dc:title":["Air pollutant emissions from non-vented radiant kerosene heater"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:43:55Z"}