{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4586"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4586","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Behavior of reinforced fibrous beam-column joints under cyclic loads","abstract":"<p>From exploratory research of reinforced fibrous concrete, it has been shown that fibrous concrete is potentially superior and less costly than the conventional reinforced concrete.</p><p>The testing program consisted of ten beam-column joints with half of these joints containing 1-1/2 percent hooked end fibers. The beam column joints were constructed with less hoops than a conventional seismic joint would have, according to design specifications of the American Concrete Institute Code (ACI 318-77). In studying the behavior of these beam-column joints, two loading cases were examined:</p><p>(1) critical regions whose inelastic behavior was controlled by bending, and</p><p>(2) critical regions whose inelastic behavior was controlled by high shear existing in the region rather than bending.</p><p>From the analysis of the results, it can safely be concluded that the hooked ended steel fibers in the joint region provided</p><p>(1) better bond</p><p>(2) better confinement of the concrete</p><p>(3) a stiffer member</p><p>(4) higher moment capacity</p><p>(5) higher shear strength</p><p>(6) more ductility, and</p><p>(7) significant improvement in the energy dissipation capacity than did the plain concrete joint.</p>","abstract_html":"&lt;p&gt;From exploratory research of reinforced fibrous concrete, it has been shown that fibrous concrete is potentially superior and less costly than the conventional reinforced concrete.&lt;/p&gt;&lt;p&gt;The testing program consisted of ten beam-column joints with half of these joints containing 1-1/2 percent hooked end fibers. The beam column joints were constructed with less hoops than a conventional seismic joint would have, according to design specifications of the American Concrete Institute Code (ACI 318-77). In studying the behavior of these beam-column joints, two loading cases were examined:&lt;/p&gt;&lt;p&gt;(1) critical regions whose inelastic behavior was controlled by bending, and&lt;/p&gt;&lt;p&gt;(2) critical regions whose inelastic behavior was controlled by high shear existing in the region rather than bending.&lt;/p&gt;&lt;p&gt;From the analysis of the results, it can safely be concluded that the hooked ended steel fibers in the joint region provided&lt;/p&gt;&lt;p&gt;(1) better bond&lt;/p&gt;&lt;p&gt;(2) better confinement of the concrete&lt;/p&gt;&lt;p&gt;(3) a stiffer member&lt;/p&gt;&lt;p&gt;(4) higher moment capacity&lt;/p&gt;&lt;p&gt;(5) higher shear strength&lt;/p&gt;&lt;p&gt;(6) more ductility, and&lt;/p&gt;&lt;p&gt;(7) significant improvement in the energy dissipation capacity than did the plain concrete joint.&lt;/p&gt;","abstract_has_math":false,"creators":["Mahadev, Sitaram"],"institution":null,"degree_name":"Master of Science in Civil Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["R. John Craig","C.T. Thomas Hsu","Frederick G. Lehman"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:44:11Z","subjects":["Fiber reinforced concrete","Concrete construction -- Joints","Civil Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3562","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3562","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4586","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["R. John Craig","C.T. Thomas Hsu","Frederick G. Lehman"]},{"key":"dc:creator","label":"Author","values":["Mahadev, Sitaram"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1983-01-31T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Civil Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fiber reinforced concrete","Concrete construction -- Joints","Civil Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3562"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>From exploratory research of reinforced fibrous concrete, it has been shown that fibrous concrete is potentially superior and less costly than the conventional reinforced concrete.</p><p>The testing program consisted of ten beam-column joints with half of these joints containing 1-1/2 percent hooked end fibers. The beam column joints were constructed with less hoops than a conventional seismic joint would have, according to design specifications of the American Concrete Institute Code (ACI 318-77). In studying the behavior of these beam-column joints, two loading cases were examined:</p><p>(1) critical regions whose inelastic behavior was controlled by bending, and</p><p>(2) critical regions whose inelastic behavior was controlled by high shear existing in the region rather than bending.</p><p>From the analysis of the results, it can safely be concluded that the hooked ended steel fibers in the joint region provided</p><p>(1) better bond</p><p>(2) better confinement of the concrete</p><p>(3) a stiffer member</p><p>(4) higher moment capacity</p><p>(5) higher shear strength</p><p>(6) more ductility, and</p><p>(7) significant improvement in the energy dissipation capacity than did the plain concrete joint.</p>"]},{"key":"dc:title","label":"Title","values":["Behavior of reinforced fibrous beam-column joints under cyclic loads"]}]}],"canonical_facts":{"dc:contributor":["R. John Craig","C.T. Thomas Hsu","Frederick G. Lehman"],"dc:creator":["Mahadev, Sitaram"],"dc:date.created":["1983-01-31T08:00:00Z"],"dc:description.abstract":["<p>From exploratory research of reinforced fibrous concrete, it has been shown that fibrous concrete is potentially superior and less costly than the conventional reinforced concrete.</p><p>The testing program consisted of ten beam-column joints with half of these joints containing 1-1/2 percent hooked end fibers. The beam column joints were constructed with less hoops than a conventional seismic joint would have, according to design specifications of the American Concrete Institute Code (ACI 318-77). In studying the behavior of these beam-column joints, two loading cases were examined:</p><p>(1) critical regions whose inelastic behavior was controlled by bending, and</p><p>(2) critical regions whose inelastic behavior was controlled by high shear existing in the region rather than bending.</p><p>From the analysis of the results, it can safely be concluded that the hooked ended steel fibers in the joint region provided</p><p>(1) better bond</p><p>(2) better confinement of the concrete</p><p>(3) a stiffer member</p><p>(4) higher moment capacity</p><p>(5) higher shear strength</p><p>(6) more ductility, and</p><p>(7) significant improvement in the energy dissipation capacity than did the plain concrete joint.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3562"],"dc:subject":["Fiber reinforced concrete","Concrete construction -- Joints","Civil Engineering"],"dc:title":["Behavior of reinforced fibrous beam-column joints under cyclic loads"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Civil Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:44:11Z"}