{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-4658"},"canonical_url":"https://search.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-4658","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"The effect of chronic low level lead ingestion on blood pressure in young dogs","abstract":"<p>The relationship between chronic, low level lead exposure and hypertension has been a controversial issue for nearly a century. This study was designed to examine if such exposure is capable of causing hypertension in young dogs. Twelve three-month old female hounds were split into groups of six and paired with their littermate. One group received a dose of 1 mg/kg body weight of lead daily (orally); the controls received equimolar sodium acetate. Blood pressures were determined using an indirect Doppler technique.</p><p>Similar blood pressures were recorded for both groups prior to lead dosing. After nine days of lead ingestion, the mean blood pressure of the lead group had risen to 111Â±9.5 mm Hg (XÂ±SEM), as compared to 88Â±7.5 mm Hg in their controls (P<0.05). This increase in mean blood pressure was sustained throughout the 140 day experimental period. Final values were 120Â±2.1 mm Hg in the lead dogs and 108Â±1.5 mm Hg in their paired controls (P<0.005).</p><p>Plasma renin activity was shown to be elevated at one month in the lead dogs but returned to normal at two months for the remainder of the study. An increased renin response to Lasix at 140 days was seen in the lead poisoned dogs. No differences in extracellular fluid volumes, plasma volumes, or serum aldosterones were seen. Renal function was normal at 140 days. An analysis of mean blood pressure to serum catecholamines was done, revealing a higher mean blood pressure in lead exposed dogs than controls for any level of serum catecholamines.</p>","abstract_html":"&lt;p&gt;The relationship between chronic, low level lead exposure and hypertension has been a controversial issue for nearly a century. This study was designed to examine if such exposure is capable of causing hypertension in young dogs. Twelve three-month old female hounds were split into groups of six and paired with their littermate. One group received a dose of 1 mg/kg body weight of lead daily (orally); the controls received equimolar sodium acetate. Blood pressures were determined using an indirect Doppler technique.&lt;/p&gt;&lt;p&gt;Similar blood pressures were recorded for both groups prior to lead dosing. After nine days of lead ingestion, the mean blood pressure of the lead group had risen to 111Â±9.5 mm Hg (XÂ±SEM), as compared to 88Â±7.5 mm Hg in their controls (P&lt;0.05). This increase in mean blood pressure was sustained throughout the 140 day experimental period. Final values were 120Â±2.1 mm Hg in the lead dogs and 108Â±1.5 mm Hg in their paired controls (P&lt;0.005).&lt;/p&gt;&lt;p&gt;Plasma renin activity was shown to be elevated at one month in the lead dogs but returned to normal at two months for the remainder of the study. An increased renin response to Lasix at 140 days was seen in the lead poisoned dogs. No differences in extracellular fluid volumes, plasma volumes, or serum aldosterones were seen. Renal function was normal at 140 days. An analysis of mean blood pressure to serum catecholamines was done, revealing a higher mean blood pressure in lead exposed dogs than controls for any level of serum catecholamines.&lt;/p&gt;","abstract_has_math":false,"creators":["Vetrano, Thomas Robert"],"institution":null,"degree_name":"Master of Science in Environmental Engineering - (M.S.)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Burton P. Fine","Richard B. Trattner"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:44:18Z","subjects":["Lead-poisoning in animals","Hypertension","Environmental Engineering","Toxicology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/3634","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.njit.edu/theses/3634","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.njit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.njit.edu%3Atheses-4658","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Burton P. Fine","Richard B. Trattner"]},{"key":"dc:creator","label":"Author","values":["Vetrano, Thomas Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1984-05-31T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Environmental Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Lead-poisoning in animals","Hypertension","Environmental Engineering","Toxicology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/3634"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The relationship between chronic, low level lead exposure and hypertension has been a controversial issue for nearly a century. This study was designed to examine if such exposure is capable of causing hypertension in young dogs. Twelve three-month old female hounds were split into groups of six and paired with their littermate. One group received a dose of 1 mg/kg body weight of lead daily (orally); the controls received equimolar sodium acetate. Blood pressures were determined using an indirect Doppler technique.</p><p>Similar blood pressures were recorded for both groups prior to lead dosing. After nine days of lead ingestion, the mean blood pressure of the lead group had risen to 111Â±9.5 mm Hg (XÂ±SEM), as compared to 88Â±7.5 mm Hg in their controls (P<0.05). This increase in mean blood pressure was sustained throughout the 140 day experimental period. Final values were 120Â±2.1 mm Hg in the lead dogs and 108Â±1.5 mm Hg in their paired controls (P<0.005).</p><p>Plasma renin activity was shown to be elevated at one month in the lead dogs but returned to normal at two months for the remainder of the study. An increased renin response to Lasix at 140 days was seen in the lead poisoned dogs. No differences in extracellular fluid volumes, plasma volumes, or serum aldosterones were seen. Renal function was normal at 140 days. An analysis of mean blood pressure to serum catecholamines was done, revealing a higher mean blood pressure in lead exposed dogs than controls for any level of serum catecholamines.</p>"]},{"key":"dc:title","label":"Title","values":["The effect of chronic low level lead ingestion on blood pressure in young dogs"]}]}],"canonical_facts":{"dc:contributor":["Burton P. Fine","Richard B. Trattner"],"dc:creator":["Vetrano, Thomas Robert"],"dc:date.created":["1984-05-31T07:00:00Z"],"dc:description.abstract":["<p>The relationship between chronic, low level lead exposure and hypertension has been a controversial issue for nearly a century. This study was designed to examine if such exposure is capable of causing hypertension in young dogs. Twelve three-month old female hounds were split into groups of six and paired with their littermate. One group received a dose of 1 mg/kg body weight of lead daily (orally); the controls received equimolar sodium acetate. Blood pressures were determined using an indirect Doppler technique.</p><p>Similar blood pressures were recorded for both groups prior to lead dosing. After nine days of lead ingestion, the mean blood pressure of the lead group had risen to 111Â±9.5 mm Hg (XÂ±SEM), as compared to 88Â±7.5 mm Hg in their controls (P<0.05). This increase in mean blood pressure was sustained throughout the 140 day experimental period. Final values were 120Â±2.1 mm Hg in the lead dogs and 108Â±1.5 mm Hg in their paired controls (P<0.005).</p><p>Plasma renin activity was shown to be elevated at one month in the lead dogs but returned to normal at two months for the remainder of the study. An increased renin response to Lasix at 140 days was seen in the lead poisoned dogs. No differences in extracellular fluid volumes, plasma volumes, or serum aldosterones were seen. Renal function was normal at 140 days. An analysis of mean blood pressure to serum catecholamines was done, revealing a higher mean blood pressure in lead exposed dogs than controls for any level of serum catecholamines.</p>"],"dc:identifier":["https://digitalcommons.njit.edu/theses/3634"],"dc:subject":["Lead-poisoning in animals","Hypertension","Environmental Engineering","Toxicology"],"dc:title":["The effect of chronic low level lead ingestion on blood pressure in young dogs"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science in Environmental Engineering - (M.S.)"]},"updated_at":"2026-11-19T08:44:18Z"}