{"id":{"repo_id":"nodak","oai_identifier":"oai:commons.und.edu:theses-5549"},"canonical_url":"https://search.ndltd.org/etd/nodak/oai:commons.und.edu:theses-5549","repository":{"repo_id":"nodak","name":"University of North Dakota","base_url":"https://commons.und.edu/do/oai/"},"display":{"title":"Improved Pressure Loss And Multiphase Flow Behavior Predictions For In-Line Gas-Liquid Contactors Using Experimental Measurements And CFD Simulations","abstract":"Treatment of gas by liquid absorption is a common unit operation in industry. Traditionally, contact between the gas and liquid is accomplished in co-current flow utilizing a tower or column. With the increased demand for natural gas and renewable gas, higher treating capacities for new installations and methods for de-bottlenecking existing plants are needed. Co-current gas treating with static mixers is an increasingly attractive alternative for process intensification. The corrugated plate (SMV-style) mixer is currently the most widely used mixing element for gas-continuous mixing with a liquid phase and has been recommended as the best standard option for this service. These geometries are also used as structured packing for counter-current service. Unfortunately, the pressure loss correlations available to the design engineer are sparse and only valid up to Re_G<50,000. In contrast, most gas pipelines operate in the range of 10^5","abstract_html":"Treatment of gas by liquid absorption is a common unit operation in industry. Traditionally, contact between the gas and liquid is accomplished in co-current flow utilizing a tower or column. With the increased demand for natural gas and renewable gas, higher treating capacities for new installations and methods for de-bottlenecking existing plants are needed. Co-current gas treating with static mixers is an increasingly attractive alternative for process intensification. The corrugated plate (SMV-style) mixer is currently the most widely used mixing element for gas-continuous mixing with a liquid phase and has been recommended as the best standard option for this service. These geometries are also used as structured packing for counter-current service. Unfortunately, the pressure loss correlations available to the design engineer are sparse and only valid up to Re_G&lt;50,000. In contrast, most gas pipelines operate in the range of 10^5","abstract_has_math":false,"creators":["Lowry, Evan"],"institution":null,"degree_name":"Doctor of Philosophy (PhD)","degree_level":"Dissertation","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Gautham Krishnamoorthy"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:05:34Z","subjects":["Computational Fluid Dynamics, Fluid Dynamics, Pressure Loss"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://commons.und.edu/theses/4546","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://commons.und.edu/theses/4546","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anodak%3Aoai%3Acommons.und.edu%3Atheses-5549","prefix":"oai_dc"},"source_record":{"url":"https://commons.und.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Acommons.und.edu%3Atheses-5549","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gautham Krishnamoorthy"]},{"key":"dc:creator","label":"Author","values":["Lowry, Evan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2022-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computational Fluid Dynamics, Fluid Dynamics, Pressure Loss"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://commons.und.edu/theses/4546"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Treatment of gas by liquid absorption is a common unit operation in industry. Traditionally, contact between the gas and liquid is accomplished in co-current flow utilizing a tower or column. With the increased demand for natural gas and renewable gas, higher treating capacities for new installations and methods for de-bottlenecking existing plants are needed. Co-current gas treating with static mixers is an increasingly attractive alternative for process intensification. The corrugated plate (SMV-style) mixer is currently the most widely used mixing element for gas-continuous mixing with a liquid phase and has been recommended as the best standard option for this service. These geometries are also used as structured packing for counter-current service. Unfortunately, the pressure loss correlations available to the design engineer are sparse and only valid up to Re_G<50,000. In contrast, most gas pipelines operate in the range of 10^5"]},{"key":"dc:title","label":"Title","values":["Improved Pressure Loss And Multiphase Flow Behavior Predictions For In-Line Gas-Liquid Contactors Using Experimental Measurements And CFD Simulations"]}]}],"canonical_facts":{"dc:contributor":["Gautham Krishnamoorthy"],"dc:creator":["Lowry, Evan"],"dc:date.created":["2022-12-01T08:00:00Z"],"dc:description.abstract":["Treatment of gas by liquid absorption is a common unit operation in industry. Traditionally, contact between the gas and liquid is accomplished in co-current flow utilizing a tower or column. With the increased demand for natural gas and renewable gas, higher treating capacities for new installations and methods for de-bottlenecking existing plants are needed. Co-current gas treating with static mixers is an increasingly attractive alternative for process intensification. The corrugated plate (SMV-style) mixer is currently the most widely used mixing element for gas-continuous mixing with a liquid phase and has been recommended as the best standard option for this service. These geometries are also used as structured packing for counter-current service. Unfortunately, the pressure loss correlations available to the design engineer are sparse and only valid up to Re_G<50,000. In contrast, most gas pipelines operate in the range of 10^5"],"dc:identifier":["https://commons.und.edu/theses/4546"],"dc:subject":["Computational Fluid Dynamics, Fluid Dynamics, Pressure Loss"],"dc:title":["Improved Pressure Loss And Multiphase Flow Behavior Predictions For In-Line Gas-Liquid Contactors Using Experimental Measurements And CFD Simulations"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy (PhD)"]},"updated_at":"2026-11-27T04:05:34Z"}