{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/1005"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/1005","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"An experimental study of high heat flux removal using micro-droplet spray cooling","abstract":"Recent studies have shown that thermophotovoltaic (TPV) technology is a promising source of high power density generation. Enhanced TPV systems can theoretically provide power densities of up to 100 W/cm2. The inherent ineffiencies in the system dictate that up to 90% of that energy is not converted to electrical power, and must be removed as waste heat to ensure that the components are maintained at a reasonable operating temperature. The present study addresses this issue by investigating the suitability of using spray cooling techniques to remove heat generated by power densities of up to 100 W/cm2. A simple, scaleable experiment was designed using low-cost commercially available components to study the effects that spray mass flux and droplet size have on the heat removal capacity of the system. A series of nozzles were used so that mass flux and droplet size could be studied independently, giving high resolution to the data so that predictive correlations could be developed over the range of parameters varied in the study.","abstract_html":"Recent studies have shown that thermophotovoltaic (TPV) technology is a promising source of high power density generation. Enhanced TPV systems can theoretically provide power densities of up to 100 W/cm2. The inherent ineffiencies in the system dictate that up to 90% of that energy is not converted to electrical power, and must be removed as waste heat to ensure that the components are maintained at a reasonable operating temperature. The present study addresses this issue by investigating the suitability of using spray cooling techniques to remove heat generated by power densities of up to 100 W/cm2. A simple, scaleable experiment was designed using low-cost commercially available components to study the effects that spray mass flux and droplet size have on the heat removal capacity of the system. A series of nozzles were used so that mass flux and droplet size could be studied independently, giving high resolution to the data so that predictive correlations could be developed over the range of parameters varied in the study.","abstract_has_math":false,"creators":["Cryer, Matthew A."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Gopinath, Ashok"],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003-06","date_published":"2003-06","updated_at":"2026-11-19T06:02:29Z","subjects":["Spraying","Cooling","Nucleate boiling","Heat","Transmission"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["52807443"],"render_values":[{"text":"52807443","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/1005","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/1005","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F1005","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F1005","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gopinath, Ashok"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Cryer, Matthew A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:30:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:30:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2003-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Spraying","Cooling","Nucleate boiling","Heat","Transmission"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["52807443"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/1005"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent studies have shown that thermophotovoltaic (TPV) technology is a promising source of high power density generation. Enhanced TPV systems can theoretically provide power densities of up to 100 W/cm2. The inherent ineffiencies in the system dictate that up to 90% of that energy is not converted to electrical power, and must be removed as waste heat to ensure that the components are maintained at a reasonable operating temperature. The present study addresses this issue by investigating the suitability of using spray cooling techniques to remove heat generated by power densities of up to 100 W/cm2. A simple, scaleable experiment was designed using low-cost commercially available components to study the effects that spray mass flux and droplet size have on the heat removal capacity of the system. A series of nozzles were used so that mass flux and droplet size could be studied independently, giving high resolution to the data so that predictive correlations could be developed over the range of parameters varied in the study."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/anexperimentalst109451005"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xvi, 43 p. : ill. (some col.) ;"]},{"key":"dc:title","label":"Title","values":["An experimental study of high heat flux removal using micro-droplet spray cooling"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["US Naval Reserve (USNR) author."]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gopinath, Ashok"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Cryer, Matthew A."],"dc:date.accessioned":["2012-03-14T17:30:14Z"],"dc:date.available":["2012-03-14T17:30:14Z"],"dc:date.issued":["2003-06"],"dc:description.abstract":["Recent studies have shown that thermophotovoltaic (TPV) technology is a promising source of high power density generation. Enhanced TPV systems can theoretically provide power densities of up to 100 W/cm2. The inherent ineffiencies in the system dictate that up to 90% of that energy is not converted to electrical power, and must be removed as waste heat to ensure that the components are maintained at a reasonable operating temperature. The present study addresses this issue by investigating the suitability of using spray cooling techniques to remove heat generated by power densities of up to 100 W/cm2. A simple, scaleable experiment was designed using low-cost commercially available components to study the effects that spray mass flux and droplet size have on the heat removal capacity of the system. A series of nozzles were used so that mass flux and droplet size could be studied independently, giving high resolution to the data so that predictive correlations could be developed over the range of parameters varied in the study."],"dc:description.uri":["http://archive.org/details/anexperimentalst109451005"],"dc:format.extent":["xvi, 43 p. : ill. (some col.) ;"],"dc:identifier.oclc":["52807443"],"dc:identifier.uri":["https://hdl.handle.net/10945/1005"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:subject.lcsh":["Spraying","Cooling","Nucleate boiling","Heat","Transmission"],"dc:title":["An experimental study of high heat flux removal using micro-droplet spray cooling"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["US Naval Reserve (USNR) author."],"local:etd.verified":["no"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:02:29Z"}