{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/10226"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/10226","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Robust model-based fault diganosis [sic] for a DC zonal electrical distribution system","abstract":"A key element of the U.S. Navy's transition to an electric naval force is an Integrated Power System (IPS) that provides continuity of service to vital systems despite combat damage. In order to meet subsequent survivability standards under a reduced manning constraint, the IPS system must include a fault tolerant control scheme, capable of achieving automated graceful degradation despite major disruptions involving cascading failures. Toward this objective, online modelbased residual generation techniques are proposed, which identify explicitly defined faults within a stochastic DC Zonal Electrical Distribution System (DC ZEDS). Two novel polynomial approaches to the design of unknown input observers (UIO) are developed to estimate the partial state and, under certain conditions, the unknown input. These methods are shown to apply to a larger class of systems compared to standard projection based approaches where the UIO rank condition is not satisfied. It is shown that the partial-state estimate is sufficient to the computation of residuals for fault diagnosis, even in such cases where full-state estimation is not possible. In order to reduce the complexity of the system, a modular approach to Fault Detection and Isolation (FDI) is presented. Here, the innovations generated from a bank of Kalman filters (some of them UIOs) act as a structured residual set for the stochastic DC ZEDS subsystem modules and are shown to detect and isolate various classes of faults. Certain mathematical models are also shown to effectively identify input/output consistency of systems in explicitly defined fault conditions. Numerical simulation results are based on the well-documented Office of Naval Research Control Challenge benchmark system, which represents a prototypical U.S. Navy shipboard IPS power distribution system.","abstract_html":"A key element of the U.S. Navy&#x27;s transition to an electric naval force is an Integrated Power System (IPS) that provides continuity of service to vital systems despite combat damage. In order to meet subsequent survivability standards under a reduced manning constraint, the IPS system must include a fault tolerant control scheme, capable of achieving automated graceful degradation despite major disruptions involving cascading failures. Toward this objective, online modelbased residual generation techniques are proposed, which identify explicitly defined faults within a stochastic DC Zonal Electrical Distribution System (DC ZEDS). Two novel polynomial approaches to the design of unknown input observers (UIO) are developed to estimate the partial state and, under certain conditions, the unknown input. These methods are shown to apply to a larger class of systems compared to standard projection based approaches where the UIO rank condition is not satisfied. It is shown that the partial-state estimate is sufficient to the computation of residuals for fault diagnosis, even in such cases where full-state estimation is not possible. In order to reduce the complexity of the system, a modular approach to Fault Detection and Isolation (FDI) is presented. Here, the innovations generated from a bank of Kalman filters (some of them UIOs) act as a structured residual set for the stochastic DC ZEDS subsystem modules and are shown to detect and isolate various classes of faults. Certain mathematical models are also shown to effectively identify input/output consistency of systems in explicitly defined fault conditions. Numerical simulation results are based on the well-documented Office of Naval Research Control Challenge benchmark system, which represents a prototypical U.S. Navy shipboard IPS power distribution system.","abstract_has_math":false,"creators":["Stevens, John D."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Doctor of Philosophy in Electrical Engineering","degree_level":"Doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Cristi, Roberto"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-06","date_published":"2007-06","updated_at":"2026-11-19T06:02:29Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/10226","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/10226","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F10226","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F10226","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cristi, Roberto"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Stevens, John D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-22T15:31:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-22T15:31:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88110183-ea50-46f5-b469-809c1418a16d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Unknown Input Observers","Fault Diagnosis","Residual Generation","Power Electronics","DC Zonal Electrical Distribution System"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/10226"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A key element of the U.S. Navy's transition to an electric naval force is an Integrated Power System (IPS) that provides continuity of service to vital systems despite combat damage. In order to meet subsequent survivability standards under a reduced manning constraint, the IPS system must include a fault tolerant control scheme, capable of achieving automated graceful degradation despite major disruptions involving cascading failures. Toward this objective, online modelbased residual generation techniques are proposed, which identify explicitly defined faults within a stochastic DC Zonal Electrical Distribution System (DC ZEDS). Two novel polynomial approaches to the design of unknown input observers (UIO) are developed to estimate the partial state and, under certain conditions, the unknown input. These methods are shown to apply to a larger class of systems compared to standard projection based approaches where the UIO rank condition is not satisfied. It is shown that the partial-state estimate is sufficient to the computation of residuals for fault diagnosis, even in such cases where full-state estimation is not possible. In order to reduce the complexity of the system, a modular approach to Fault Detection and Isolation (FDI) is presented. Here, the innovations generated from a bank of Kalman filters (some of them UIOs) act as a structured residual set for the stochastic DC ZEDS subsystem modules and are shown to detect and isolate various classes of faults. Certain mathematical models are also shown to effectively identify input/output consistency of systems in explicitly defined fault conditions. Numerical simulation results are based on the well-documented Office of Naval Research Control Challenge benchmark system, which represents a prototypical U.S. Navy shipboard IPS power distribution system."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/robustmodelbased1094510226"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["200 p."]},{"key":"dc:title","label":"Title","values":["Robust model-based fault diganosis [sic] for a DC zonal electrical distribution system"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cristi, Roberto"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Stevens, John D."],"dc:date.accessioned":["2012-08-22T15:31:38Z"],"dc:date.available":["2012-08-22T15:31:38Z"],"dc:date.issued":["2007-06"],"dc:description.abstract":["A key element of the U.S. Navy's transition to an electric naval force is an Integrated Power System (IPS) that provides continuity of service to vital systems despite combat damage. In order to meet subsequent survivability standards under a reduced manning constraint, the IPS system must include a fault tolerant control scheme, capable of achieving automated graceful degradation despite major disruptions involving cascading failures. Toward this objective, online modelbased residual generation techniques are proposed, which identify explicitly defined faults within a stochastic DC Zonal Electrical Distribution System (DC ZEDS). Two novel polynomial approaches to the design of unknown input observers (UIO) are developed to estimate the partial state and, under certain conditions, the unknown input. These methods are shown to apply to a larger class of systems compared to standard projection based approaches where the UIO rank condition is not satisfied. It is shown that the partial-state estimate is sufficient to the computation of residuals for fault diagnosis, even in such cases where full-state estimation is not possible. In order to reduce the complexity of the system, a modular approach to Fault Detection and Isolation (FDI) is presented. Here, the innovations generated from a bank of Kalman filters (some of them UIOs) act as a structured residual set for the stochastic DC ZEDS subsystem modules and are shown to detect and isolate various classes of faults. Certain mathematical models are also shown to effectively identify input/output consistency of systems in explicitly defined fault conditions. Numerical simulation results are based on the well-documented Office of Naval Research Control Challenge benchmark system, which represents a prototypical U.S. Navy shipboard IPS power distribution system."],"dc:description.uri":["http://archive.org/details/robustmodelbased1094510226"],"dc:format.extent":["200 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/10226"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["88110183-ea50-46f5-b469-809c1418a16d"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Unknown Input Observers","Fault Diagnosis","Residual Generation","Power Electronics","DC Zonal Electrical Distribution System"],"dc:title":["Robust model-based fault diganosis [sic] for a DC zonal electrical distribution system"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:02:29Z"}