{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/11559"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/11559","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Adaptive sampling frequency for sampled-data control systems","abstract":"Sampled-data control systems generally have fixed sampling frequencies which must be set high enough to give satisfactory performance for all anticipated conditions, A study is made here of an adaptive system which varies the sampling frequency by measuring a system parameter. It is shown, that a sampler followed by a zero-order hold whose sampling period is controlled by the absolute value of the first derivative of the error signal will be a more \"efficient\" sampler than a fixed frequency sampler. That is, over a given time interval, fewer samples are needed with the variable frequency system than with a fixed frequency system while maintaining essentially the same response characteristics. Analog computer studies of simple type 1 and type 2 sampled-data servo systems with error sampling and unity feedback verified the method . Standard analog computer components were used to set up a simulated servo system, a rate detector, absolute value detector, a voltage controlled oscillator, and a sampler and zero-order hold. The system described reduced the number of samples required for response to a step input to about three-quarters that required in a fixed sampling frequency system. Over a long period of time, savings in the number of samples required can be expected to be between twenty-five and fifty per cent. In many applications, the saving produced by reducing the overall number of samples required may outweigh the added complexity of the adaptive sampling frequency system.","abstract_html":"Sampled-data control systems generally have fixed sampling frequencies which must be set high enough to give satisfactory performance for all anticipated conditions, A study is made here of an adaptive system which varies the sampling frequency by measuring a system parameter. It is shown, that a sampler followed by a zero-order hold whose sampling period is controlled by the absolute value of the first derivative of the error signal will be a more &quot;efficient&quot; sampler than a fixed frequency sampler. That is, over a given time interval, fewer samples are needed with the variable frequency system than with a fixed frequency system while maintaining essentially the same response characteristics. Analog computer studies of simple type 1 and type 2 sampled-data servo systems with error sampling and unity feedback verified the method . Standard analog computer components were used to set up a simulated servo system, a rate detector, absolute value detector, a voltage controlled oscillator, and a sampler and zero-order hold. The system described reduced the number of samples required for response to a step input to about three-quarters that required in a fixed sampling frequency system. Over a long period of time, savings in the number of samples required can be expected to be between twenty-five and fifty per cent. In many applications, the saving produced by reducing the overall number of samples required may outweigh the added complexity of the adaptive sampling frequency system.","abstract_has_math":false,"creators":["Farren, Merritt C.","Phillips, Charles A."],"institution":"Monterey, California: U.S. Naval Postgraduate School","degree_name":"M.S. in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Dorf, Richard C."],"committee_chairs":[],"committee_members":[],"year":1960,"date_issued":"1960","date_published":"1960","updated_at":"2026-11-21T22:53:13Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/11559","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/11559","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F11559","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F11559","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dorf, Richard C."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Farren, Merritt C.","Phillips, Charles A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:28:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:28:14Z"]},{"key":"dc:date.issued","label":"Date","values":["1960"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/11559"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Sampled-data control systems generally have fixed sampling frequencies which must be set high enough to give satisfactory performance for all anticipated conditions, A study is made here of an adaptive system which varies the sampling frequency by measuring a system parameter. It is shown, that a sampler followed by a zero-order hold whose sampling period is controlled by the absolute value of the first derivative of the error signal will be a more \"efficient\" sampler than a fixed frequency sampler. That is, over a given time interval, fewer samples are needed with the variable frequency system than with a fixed frequency system while maintaining essentially the same response characteristics. Analog computer studies of simple type 1 and type 2 sampled-data servo systems with error sampling and unity feedback verified the method . Standard analog computer components were used to set up a simulated servo system, a rate detector, absolute value detector, a voltage controlled oscillator, and a sampler and zero-order hold. The system described reduced the number of samples required for response to a step input to about three-quarters that required in a fixed sampling frequency system. Over a long period of time, savings in the number of samples required can be expected to be between twenty-five and fifty per cent. In many applications, the saving produced by reducing the overall number of samples required may outweigh the added complexity of the adaptive sampling frequency system."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/adaptivesampling1094511559"]},{"key":"dc:title","label":"Title","values":["Adaptive sampling frequency for sampled-data control systems"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dorf, Richard C."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Farren, Merritt C.","Phillips, Charles A."],"dc:date.accessioned":["2012-08-29T23:28:14Z"],"dc:date.available":["2012-08-29T23:28:14Z"],"dc:date.issued":["1960"],"dc:description.abstract":["Sampled-data control systems generally have fixed sampling frequencies which must be set high enough to give satisfactory performance for all anticipated conditions, A study is made here of an adaptive system which varies the sampling frequency by measuring a system parameter. It is shown, that a sampler followed by a zero-order hold whose sampling period is controlled by the absolute value of the first derivative of the error signal will be a more \"efficient\" sampler than a fixed frequency sampler. That is, over a given time interval, fewer samples are needed with the variable frequency system than with a fixed frequency system while maintaining essentially the same response characteristics. Analog computer studies of simple type 1 and type 2 sampled-data servo systems with error sampling and unity feedback verified the method . Standard analog computer components were used to set up a simulated servo system, a rate detector, absolute value detector, a voltage controlled oscillator, and a sampler and zero-order hold. The system described reduced the number of samples required for response to a step input to about three-quarters that required in a fixed sampling frequency system. Over a long period of time, savings in the number of samples required can be expected to be between twenty-five and fifty per cent. In many applications, the saving produced by reducing the overall number of samples required may outweigh the added complexity of the adaptive sampling frequency system."],"dc:description.uri":["http://archive.org/details/adaptivesampling1094511559"],"dc:identifier.uri":["https://hdl.handle.net/10945/11559"],"dc:publisher":["Monterey, California: U.S. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:title":["Adaptive sampling frequency for sampled-data control systems"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:53:13Z"}