{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/11664"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/11664","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The application of dynamic polarization to earth's field nuclear resonance magnetometers","abstract":"The principle of Nuclear Magnetic Resonance has, for many years, been applied to the measurement of the earth's magnetic field. Of the magnetometers based on this principle, the Free Precession Magnetometer gives the best absolute accuracy available today. Disadvantages of this device are its comparatively slow data rate and transients created by the polarizing current pulses. The application of the Overhauser Effect, or Dynamic Polarization, to a nuclear resonance magnetometer offers advantages in increased data rate and accuracy. Such magnetometers have been limited by the short lifetime of the sample material. Three devices, in which dynamic polarization is used, are described. One of these, a maser oscillator, seems particularly promising. Also included is a study of the requirements for long-lifetime materials suitable for use in a magnetometer.","abstract_html":"The principle of Nuclear Magnetic Resonance has, for many years, been applied to the measurement of the earth&#x27;s magnetic field. Of the magnetometers based on this principle, the Free Precession Magnetometer gives the best absolute accuracy available today. Disadvantages of this device are its comparatively slow data rate and transients created by the polarizing current pulses. The application of the Overhauser Effect, or Dynamic Polarization, to a nuclear resonance magnetometer offers advantages in increased data rate and accuracy. Such magnetometers have been limited by the short lifetime of the sample material. Three devices, in which dynamic polarization is used, are described. One of these, a maser oscillator, seems particularly promising. Also included is a study of the requirements for long-lifetime materials suitable for use in a magnetometer.","abstract_has_math":false,"creators":["Burcher, Philip E.","Landrum, Raymond G."],"institution":"Monterey, California: U.S. Naval Postgraduate School","degree_name":"M.S. in Engineering Electronics","degree_level":"Masters","degree_discipline":"Engineering Electronics","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Menneken, Carl E."],"committee_chairs":[],"committee_members":[],"year":1965,"date_issued":"1965","date_published":"1965","updated_at":"2026-11-21T22:48:01Z","subjects":["Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/11664","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/11664","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F11664","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Menneken, Carl E."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Burcher, Philip E.","Landrum, Raymond G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:28:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:28:56Z"]},{"key":"dc:date.issued","label":"Date","values":["1965"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Electronics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Engineering Electronics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/11664"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The principle of Nuclear Magnetic Resonance has, for many years, been applied to the measurement of the earth's magnetic field. Of the magnetometers based on this principle, the Free Precession Magnetometer gives the best absolute accuracy available today. Disadvantages of this device are its comparatively slow data rate and transients created by the polarizing current pulses. The application of the Overhauser Effect, or Dynamic Polarization, to a nuclear resonance magnetometer offers advantages in increased data rate and accuracy. Such magnetometers have been limited by the short lifetime of the sample material. Three devices, in which dynamic polarization is used, are described. One of these, a maser oscillator, seems particularly promising. Also included is a study of the requirements for long-lifetime materials suitable for use in a magnetometer."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/thepplicationofd1094511664"]},{"key":"dc:title","label":"Title","values":["The application of dynamic polarization to earth's field nuclear resonance magnetometers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Menneken, Carl E."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Burcher, Philip E.","Landrum, Raymond G."],"dc:date.accessioned":["2012-08-29T23:28:56Z"],"dc:date.available":["2012-08-29T23:28:56Z"],"dc:date.issued":["1965"],"dc:description.abstract":["The principle of Nuclear Magnetic Resonance has, for many years, been applied to the measurement of the earth's magnetic field. Of the magnetometers based on this principle, the Free Precession Magnetometer gives the best absolute accuracy available today. Disadvantages of this device are its comparatively slow data rate and transients created by the polarizing current pulses. The application of the Overhauser Effect, or Dynamic Polarization, to a nuclear resonance magnetometer offers advantages in increased data rate and accuracy. Such magnetometers have been limited by the short lifetime of the sample material. Three devices, in which dynamic polarization is used, are described. One of these, a maser oscillator, seems particularly promising. Also included is a study of the requirements for long-lifetime materials suitable for use in a magnetometer."],"dc:description.uri":["http://archive.org/details/thepplicationofd1094511664"],"dc:identifier.uri":["https://hdl.handle.net/10945/11664"],"dc:publisher":["Monterey, California: U.S. Naval Postgraduate School"],"dc:subject.lcsh":["Electronics"],"dc:title":["The application of dynamic polarization to earth's field nuclear resonance magnetometers"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Engineering Electronics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Engineering Electronics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:48:01Z"}