{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/1176"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/1176","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Design of a bore sight camera for the lineate image near ultraviolet spectrometer (LINUS)","abstract":"The Lineate Image Near Ultraviolet Spectrometer (LINUS) is a spectral imager that works in the ultraviolet region of the spectrum. This thesis describes the latest of several steps in the development of this instrument. Due to the narrow field of view of the instrument, 2.5 x 0.5 degrees, an accurate pointing method is necessary; also, a scheme of quality evaluation of the post-processed spectral image is desirable. A way to achieve both goals was developed by designing and implementing the layout for two visual cameras, wide and narrow field of view, and a method to capture the images in order to perform the subsequent comparison with the processed spectral image. Since this is the first time the system is working in full-automated mode, a new wavelength calibration with the emission lines from a platinum hollow cathode lamp was performed and a new response curve for sulfur dioxide (SO2) was taken. Finally, laboratory and outdoor field observations were conducted to test the system integration.","abstract_html":"The Lineate Image Near Ultraviolet Spectrometer (LINUS) is a spectral imager that works in the ultraviolet region of the spectrum. This thesis describes the latest of several steps in the development of this instrument. Due to the narrow field of view of the instrument, 2.5 x 0.5 degrees, an accurate pointing method is necessary; also, a scheme of quality evaluation of the post-processed spectral image is desirable. A way to achieve both goals was developed by designing and implementing the layout for two visual cameras, wide and narrow field of view, and a method to capture the images in order to perform the subsequent comparison with the processed spectral image. Since this is the first time the system is working in full-automated mode, a new wavelength calibration with the emission lines from a platinum hollow cathode lamp was performed and a new response curve for sulfur dioxide (SO2) was taken. Finally, laboratory and outdoor field observations were conducted to test the system integration.","abstract_has_math":false,"creators":["Cabezas, Rodrigo"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Applied Science","degree_level":"Masters","degree_discipline":"Applied Science","degree_department":"Physics","school":null,"contributors":[],"advisors":["Harkins, Richard","Davis, D. Scott"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-06","date_published":"2004-06","updated_at":"2026-11-19T06:03:04Z","subjects":["Detectors","Spectrometer","Remote sensing","Cameras"],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/1176","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/1176","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F1176","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Harkins, Richard","Davis, D. Scott"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Cabezas, Rodrigo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:30:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:30:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Applied Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Detectors","Spectrometer","Remote sensing","Cameras"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/1176"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Lineate Image Near Ultraviolet Spectrometer (LINUS) is a spectral imager that works in the ultraviolet region of the spectrum. This thesis describes the latest of several steps in the development of this instrument. Due to the narrow field of view of the instrument, 2.5 x 0.5 degrees, an accurate pointing method is necessary; also, a scheme of quality evaluation of the post-processed spectral image is desirable. A way to achieve both goals was developed by designing and implementing the layout for two visual cameras, wide and narrow field of view, and a method to capture the images in order to perform the subsequent comparison with the processed spectral image. Since this is the first time the system is working in full-automated mode, a new wavelength calibration with the emission lines from a platinum hollow cathode lamp was performed and a new response curve for sulfur dioxide (SO2) was taken. Finally, laboratory and outdoor field observations were conducted to test the system integration."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/designofboresigh109451176"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 63 p. : ill. (some col.) ;"]},{"key":"dc:title","label":"Title","values":["Design of a bore sight camera for the lineate image near ultraviolet spectrometer (LINUS)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, Chilean Navy"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Harkins, Richard","Davis, D. Scott"],"dc:contributor.department":["Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Cabezas, Rodrigo"],"dc:date.accessioned":["2012-03-14T17:30:48Z"],"dc:date.available":["2012-03-14T17:30:48Z"],"dc:date.issued":["2004-06"],"dc:description.abstract":["The Lineate Image Near Ultraviolet Spectrometer (LINUS) is a spectral imager that works in the ultraviolet region of the spectrum. This thesis describes the latest of several steps in the development of this instrument. Due to the narrow field of view of the instrument, 2.5 x 0.5 degrees, an accurate pointing method is necessary; also, a scheme of quality evaluation of the post-processed spectral image is desirable. A way to achieve both goals was developed by designing and implementing the layout for two visual cameras, wide and narrow field of view, and a method to capture the images in order to perform the subsequent comparison with the processed spectral image. Since this is the first time the system is working in full-automated mode, a new wavelength calibration with the emission lines from a platinum hollow cathode lamp was performed and a new response curve for sulfur dioxide (SO2) was taken. Finally, laboratory and outdoor field observations were conducted to test the system integration."],"dc:description.uri":["http://archive.org/details/designofboresigh109451176"],"dc:format.extent":["xiv, 63 p. : ill. (some col.) ;"],"dc:identifier.uri":["https://hdl.handle.net/10945/1176"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Detectors","Spectrometer","Remote sensing","Cameras"],"dc:title":["Design of a bore sight camera for the lineate image near ultraviolet spectrometer (LINUS)"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, Chilean Navy"],"local:etd.verified":["no"],"thesis:degree_discipline":["Applied Science"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Applied Science"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:03:04Z"}