{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/11953"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/11953","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Design of an automatic flux level control system for the AGN-201 reactor","abstract":"The simulation of the kinetic equations for the AGN-201 reactor was programmed on the Donner Model 3100 analog computer. The accuracy of the simulation was verified by comparison with both a digital computer solution of the kinetic equations and with the measured time response of the AGN-201 reactor. A discontinuous (on-off) type automatic flux control system was designed and placed in closed loop operation with the simulated reactor. The sensitivity of the control system was adjusted to obtain the specified performance. The control system was then installed on the AGN-201 and the accuracy of this design technique was verified by time response measurements. The control system proved to be a simple, effective device capable of maintaining the power (flux) level of the reactor within ± 3% of the desired level at all levels of reactor operation between 0.01 and 200 watts.","abstract_html":"The simulation of the kinetic equations for the AGN-201 reactor was programmed on the Donner Model 3100 analog computer. The accuracy of the simulation was verified by comparison with both a digital computer solution of the kinetic equations and with the measured time response of the AGN-201 reactor. A discontinuous (on-off) type automatic flux control system was designed and placed in closed loop operation with the simulated reactor. The sensitivity of the control system was adjusted to obtain the specified performance. The control system was then installed on the AGN-201 and the accuracy of this design technique was verified by time response measurements. The control system proved to be a simple, effective device capable of maintaining the power (flux) level of the reactor within ± 3% of the desired level at all levels of reactor operation between 0.01 and 200 watts.","abstract_has_math":false,"creators":["Gans, George M., Jr."],"institution":"Monterey, California: U.S. Naval Postgraduate School","degree_name":"M.S. in Nuclear Engineering","degree_level":"Masters","degree_discipline":"Nuclear Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Gerba, Alex Jr."],"committee_chairs":[],"committee_members":[],"year":1963,"date_issued":"1963","date_published":"1963","updated_at":"2026-11-20T22:22:12Z","subjects":["Nuclear reactions"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/11953","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/11953","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F11953","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F11953","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gerba, Alex Jr."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Gans, George M., Jr."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1963"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:30:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:30:22Z"]},{"key":"dc:date.issued","label":"Date","values":["1963"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Nuclear Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Nuclear Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Nuclear reactions"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/11953"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The simulation of the kinetic equations for the AGN-201 reactor was programmed on the Donner Model 3100 analog computer. The accuracy of the simulation was verified by comparison with both a digital computer solution of the kinetic equations and with the measured time response of the AGN-201 reactor. A discontinuous (on-off) type automatic flux control system was designed and placed in closed loop operation with the simulated reactor. The sensitivity of the control system was adjusted to obtain the specified performance. The control system was then installed on the AGN-201 and the accuracy of this design technique was verified by time response measurements. The control system proved to be a simple, effective device capable of maintaining the power (flux) level of the reactor within ± 3% of the desired level at all levels of reactor operation between 0.01 and 200 watts."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/designofnutomati1094511953"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vi, 55 leaves 28 cm."]},{"key":"dc:title","label":"Title","values":["Design of an automatic flux level control system for the AGN-201 reactor"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gerba, Alex Jr."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Gans, George M., Jr."],"dc:date":["1963"],"dc:date.accessioned":["2012-08-29T23:30:22Z"],"dc:date.available":["2012-08-29T23:30:22Z"],"dc:date.issued":["1963"],"dc:description.abstract":["The simulation of the kinetic equations for the AGN-201 reactor was programmed on the Donner Model 3100 analog computer. The accuracy of the simulation was verified by comparison with both a digital computer solution of the kinetic equations and with the measured time response of the AGN-201 reactor. A discontinuous (on-off) type automatic flux control system was designed and placed in closed loop operation with the simulated reactor. The sensitivity of the control system was adjusted to obtain the specified performance. The control system was then installed on the AGN-201 and the accuracy of this design technique was verified by time response measurements. The control system proved to be a simple, effective device capable of maintaining the power (flux) level of the reactor within ± 3% of the desired level at all levels of reactor operation between 0.01 and 200 watts."],"dc:description.uri":["http://archive.org/details/designofnutomati1094511953"],"dc:format.extent":["vi, 55 leaves 28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/11953"],"dc:publisher":["Monterey, California: U.S. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Nuclear reactions"],"dc:title":["Design of an automatic flux level control system for the AGN-201 reactor"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Nuclear Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Nuclear Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:22:12Z"}