{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/12064"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/12064","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Effect of stator blade orientation on the performance of an axial flow compressor","abstract":"A mean streamline analysis of the effect of stator blade orientation on the performance of an axial flow compressor was performed by means of a computer program. Measurement were made on a 3-stage axial flow compressor at the Naval Postgraduate School at six stator stagger angles between 23.8 degrees and 44.3 degrees for a fixed orientation of the rotor blades. Maximum efficiency and pressure ratio were measured at a stator stagger angle of 31.8 degrees. Results at other blade settings showed that by varying stator stagger angle with flow rate optimum efficiencies and pressure rations can be achieved over a wide range of operating conditions. The result of this analysis were compared with the measured results. Suggestions are made for improving the manner of adapting cascade test data to performance predictions. By applying a non-dimensional deflection coefficient it could be shown that minimum work input corresponded to maximum efficiency. The test compressor has a tip diameter of 36 in. and a hub/tip ratio of 0.6. The blading tested is of the free-vortex type with a design degree of reaction of 0.5. Tip speed was about 185 ft/sec.","abstract_html":"A mean streamline analysis of the effect of stator blade orientation on the performance of an axial flow compressor was performed by means of a computer program. Measurement were made on a 3-stage axial flow compressor at the Naval Postgraduate School at six stator stagger angles between 23.8 degrees and 44.3 degrees for a fixed orientation of the rotor blades. Maximum efficiency and pressure ratio were measured at a stator stagger angle of 31.8 degrees. Results at other blade settings showed that by varying stator stagger angle with flow rate optimum efficiencies and pressure rations can be achieved over a wide range of operating conditions. The result of this analysis were compared with the measured results. Suggestions are made for improving the manner of adapting cascade test data to performance predictions. By applying a non-dimensional deflection coefficient it could be shown that minimum work input corresponded to maximum efficiency. The test compressor has a tip diameter of 36 in. and a hub/tip ratio of 0.6. The blading tested is of the free-vortex type with a design degree of reaction of 0.5. Tip speed was about 185 ft/sec.","abstract_has_math":false,"creators":["Marshall, Bruce Cameron"],"institution":"Monterey, California. U.S. Naval Postgraduate School","degree_name":"Degree of Aeronautical Engineer","degree_level":"Professional Degree","degree_discipline":"Aeronautical Engineering","degree_department":"Department of Aeronautics","school":null,"contributors":[],"advisors":["Vavra, M. H."],"committee_chairs":[],"committee_members":[],"year":1967,"date_issued":"1967","date_published":"1967","updated_at":"2026-11-21T22:48:16Z","subjects":["Aeronautics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/12064","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/12064","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F12064","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F12064","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Vavra, M. H."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Aeronautics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Marshall, Bruce Cameron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["September 1967"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:30:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:30:52Z"]},{"key":"dc:date.issued","label":"Date","values":["1967"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Professional Degree"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Degree of Aeronautical Engineer"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Compressor","Compressor performance","Axial flow","Variable stator","Stator blade orientation"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Aeronautics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/12064"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A mean streamline analysis of the effect of stator blade orientation on the performance of an axial flow compressor was performed by means of a computer program. Measurement were made on a 3-stage axial flow compressor at the Naval Postgraduate School at six stator stagger angles between 23.8 degrees and 44.3 degrees for a fixed orientation of the rotor blades. Maximum efficiency and pressure ratio were measured at a stator stagger angle of 31.8 degrees. Results at other blade settings showed that by varying stator stagger angle with flow rate optimum efficiencies and pressure rations can be achieved over a wide range of operating conditions. The result of this analysis were compared with the measured results. Suggestions are made for improving the manner of adapting cascade test data to performance predictions. By applying a non-dimensional deflection coefficient it could be shown that minimum work input corresponded to maximum efficiency. The test compressor has a tip diameter of 36 in. and a hub/tip ratio of 0.6. The blading tested is of the free-vortex type with a design degree of reaction of 0.5. Tip speed was about 185 ft/sec."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/effectofstatorbl1094512064"]},{"key":"dc:title","label":"Title","values":["Effect of stator blade orientation on the performance of an axial flow compressor"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Vavra, M. H."],"dc:contributor.department":["Department of Aeronautics"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Marshall, Bruce Cameron"],"dc:date":["September 1967"],"dc:date.accessioned":["2012-08-29T23:30:52Z"],"dc:date.available":["2012-08-29T23:30:52Z"],"dc:date.issued":["1967"],"dc:description.abstract":["A mean streamline analysis of the effect of stator blade orientation on the performance of an axial flow compressor was performed by means of a computer program. Measurement were made on a 3-stage axial flow compressor at the Naval Postgraduate School at six stator stagger angles between 23.8 degrees and 44.3 degrees for a fixed orientation of the rotor blades. Maximum efficiency and pressure ratio were measured at a stator stagger angle of 31.8 degrees. Results at other blade settings showed that by varying stator stagger angle with flow rate optimum efficiencies and pressure rations can be achieved over a wide range of operating conditions. The result of this analysis were compared with the measured results. Suggestions are made for improving the manner of adapting cascade test data to performance predictions. By applying a non-dimensional deflection coefficient it could be shown that minimum work input corresponded to maximum efficiency. The test compressor has a tip diameter of 36 in. and a hub/tip ratio of 0.6. The blading tested is of the free-vortex type with a design degree of reaction of 0.5. Tip speed was about 185 ft/sec."],"dc:description.uri":["http://archive.org/details/effectofstatorbl1094512064"],"dc:identifier.uri":["https://hdl.handle.net/10945/12064"],"dc:publisher":["Monterey, California. U.S. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Compressor","Compressor performance","Axial flow","Variable stator","Stator blade orientation"],"dc:subject.lcsh":["Aeronautics"],"dc:title":["Effect of stator blade orientation on the performance of an axial flow compressor"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Aeronautical Engineering"],"thesis:degree_level":["Professional Degree"],"thesis:degree_name":["Degree of Aeronautical Engineer"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:48:16Z"}