{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/12168"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/12168","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"An experimental investigation of the effects of environmental pressure on the exhaust of a coaxial plasma gun","abstract":"A coaxial plasma accelerator system was restored to working order and procedures for operating the system were established. Gold was used as the working material and was mounted as a thin circular foil between coaxial electrodes, ionized, and accelerated by discharging a high energy capacitor across the electrodes. Downstream of the electrodes, part of the gold was collected on a cylindrical collector sheet of aluminum foil. This sheet surrounded the outer electrode and extended 16 inches above the muzzle. A radioisotope tracer technique was then used to determine the mass of deposited gold on sample disks cut from selected portions of the collector sheet. It was found that only a very small percentage of the total mass was collected and that the pressure effects, in the range from .00005mm Hg to .05mm Hg, were such that an increase in exhaust pressure caused an increase in the mass of gold collected on the sheet however, pressure effects on the distribution of this mass were negligible.","abstract_html":"A coaxial plasma accelerator system was restored to working order and procedures for operating the system were established. Gold was used as the working material and was mounted as a thin circular foil between coaxial electrodes, ionized, and accelerated by discharging a high energy capacitor across the electrodes. Downstream of the electrodes, part of the gold was collected on a cylindrical collector sheet of aluminum foil. This sheet surrounded the outer electrode and extended 16 inches above the muzzle. A radioisotope tracer technique was then used to determine the mass of deposited gold on sample disks cut from selected portions of the collector sheet. It was found that only a very small percentage of the total mass was collected and that the pressure effects, in the range from .00005mm Hg to .05mm Hg, were such that an increase in exhaust pressure caused an increase in the mass of gold collected on the sheet however, pressure effects on the distribution of this mass were negligible.","abstract_has_math":false,"creators":["Smith, Michael J."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Aeronautical Engineering","degree_level":"Masters","degree_discipline":"Aeronautical Engineering","degree_department":"Aeronautics and Astronautics","school":null,"contributors":[],"advisors":["Wooten, David C."],"committee_chairs":[],"committee_members":[],"year":1968,"date_issued":"1968-03","date_published":"1968-03","updated_at":"2026-11-19T06:03:21Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/12168","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/12168","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F12168","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F12168","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wooten, David C."]},{"key":"dc:contributor.department","label":"Department","values":["Aeronautics and Astronautics"]},{"key":"dc:creator","label":"Author","values":["Smith, Michael J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:31:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:31:22Z"]},{"key":"dc:date.issued","label":"Date","values":["1968-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["34559865-c5ff-4a85-a4d6-054858776991"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Aeronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Coaxial Plasma Accelerator","Radioisotope Tracing Technique","Magnetohydrodynamics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/12168"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A coaxial plasma accelerator system was restored to working order and procedures for operating the system were established. Gold was used as the working material and was mounted as a thin circular foil between coaxial electrodes, ionized, and accelerated by discharging a high energy capacitor across the electrodes. Downstream of the electrodes, part of the gold was collected on a cylindrical collector sheet of aluminum foil. This sheet surrounded the outer electrode and extended 16 inches above the muzzle. A radioisotope tracer technique was then used to determine the mass of deposited gold on sample disks cut from selected portions of the collector sheet. It was found that only a very small percentage of the total mass was collected and that the pressure effects, in the range from .00005mm Hg to .05mm Hg, were such that an increase in exhaust pressure caused an increase in the mass of gold collected on the sheet however, pressure effects on the distribution of this mass were negligible."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/anexperimentalin1094512168"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["91 p."]},{"key":"dc:title","label":"Title","values":["An experimental investigation of the effects of environmental pressure on the exhaust of a coaxial plasma gun"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Ensign, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wooten, David C."],"dc:contributor.department":["Aeronautics and Astronautics"],"dc:creator":["Smith, Michael J."],"dc:date.accessioned":["2012-08-29T23:31:22Z"],"dc:date.available":["2012-08-29T23:31:22Z"],"dc:date.issued":["1968-03"],"dc:description.abstract":["A coaxial plasma accelerator system was restored to working order and procedures for operating the system were established. Gold was used as the working material and was mounted as a thin circular foil between coaxial electrodes, ionized, and accelerated by discharging a high energy capacitor across the electrodes. Downstream of the electrodes, part of the gold was collected on a cylindrical collector sheet of aluminum foil. This sheet surrounded the outer electrode and extended 16 inches above the muzzle. A radioisotope tracer technique was then used to determine the mass of deposited gold on sample disks cut from selected portions of the collector sheet. It was found that only a very small percentage of the total mass was collected and that the pressure effects, in the range from .00005mm Hg to .05mm Hg, were such that an increase in exhaust pressure caused an increase in the mass of gold collected on the sheet however, pressure effects on the distribution of this mass were negligible."],"dc:description.uri":["http://archive.org/details/anexperimentalin1094512168"],"dc:format.extent":["91 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/12168"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["34559865-c5ff-4a85-a4d6-054858776991"],"dc:subject.keyword":["Coaxial Plasma Accelerator","Radioisotope Tracing Technique","Magnetohydrodynamics"],"dc:title":["An experimental investigation of the effects of environmental pressure on the exhaust of a coaxial plasma gun"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Ensign, United States Navy"],"thesis:degree_discipline":["Aeronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Aeronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:03:21Z"}