{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/12241"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/12241","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Furnace Design and Calibration of High-Temperature Continuous Photograph Powder X-Ray Camera.","abstract":"Several modifications are described that were made to an x-ray camera for continuous powder photographs during programmed temperature changes. The original furnace was redesigned to extend the useful temperature range of the camera. Drawings delineating the size and operation of this furnace are included. All of the methods for furnace calibration are summarized, with special emphasis on the transition melting point technique. Materials used for furnace calibration are tabulated for easy reference. The camera with the new furnace was calibrated so that more precise high temperature measurements could be made. Further work disclosed that several more desirable features are needed; and these are given in the summary.","abstract_html":"Several modifications are described that were made to an x-ray camera for continuous powder photographs during programmed temperature changes. The original furnace was redesigned to extend the useful temperature range of the camera. Drawings delineating the size and operation of this furnace are included. All of the methods for furnace calibration are summarized, with special emphasis on the transition melting point technique. Materials used for furnace calibration are tabulated for easy reference. The camera with the new furnace was calibrated so that more precise high temperature measurements could be made. Further work disclosed that several more desirable features are needed; and these are given in the summary.","abstract_has_math":false,"creators":["Retzlaff, Robert Richard"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Material Science","degree_level":"Masters","degree_discipline":"Material Science","degree_department":"Material Science and Chemistry","school":null,"contributors":[],"advisors":["Buerger, N.W."],"committee_chairs":[],"committee_members":[],"year":1967,"date_issued":"1967-06","date_published":"1967-06","updated_at":"2026-11-19T06:03:21Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/12241","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/12241","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F12241","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F12241","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Buerger, N.W."]},{"key":"dc:contributor.department","label":"Department","values":["Material Science and Chemistry"]},{"key":"dc:creator","label":"Author","values":["Retzlaff, Robert Richard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:31:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:31:42Z"]},{"key":"dc:date.issued","label":"Date","values":["1967-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0b3a9239-df08-46ce-9142-a62354ef4f03"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Material Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Material Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/12241"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Several modifications are described that were made to an x-ray camera for continuous powder photographs during programmed temperature changes. The original furnace was redesigned to extend the useful temperature range of the camera. Drawings delineating the size and operation of this furnace are included. All of the methods for furnace calibration are summarized, with special emphasis on the transition melting point technique. Materials used for furnace calibration are tabulated for easy reference. The camera with the new furnace was calibrated so that more precise high temperature measurements could be made. Further work disclosed that several more desirable features are needed; and these are given in the summary."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/furnacedesignndc1094512241"]},{"key":"dc:title","label":"Title","values":["Furnace Design and Calibration of High-Temperature Continuous Photograph Powder X-Ray Camera."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Buerger, N.W."],"dc:contributor.department":["Material Science and Chemistry"],"dc:creator":["Retzlaff, Robert Richard"],"dc:date.accessioned":["2012-08-29T23:31:42Z"],"dc:date.available":["2012-08-29T23:31:42Z"],"dc:date.issued":["1967-06"],"dc:description.abstract":["Several modifications are described that were made to an x-ray camera for continuous powder photographs during programmed temperature changes. The original furnace was redesigned to extend the useful temperature range of the camera. Drawings delineating the size and operation of this furnace are included. All of the methods for furnace calibration are summarized, with special emphasis on the transition melting point technique. Materials used for furnace calibration are tabulated for easy reference. The camera with the new furnace was calibrated so that more precise high temperature measurements could be made. Further work disclosed that several more desirable features are needed; and these are given in the summary."],"dc:description.uri":["http://archive.org/details/furnacedesignndc1094512241"],"dc:identifier.uri":["https://hdl.handle.net/10945/12241"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["0b3a9239-df08-46ce-9142-a62354ef4f03"],"dc:title":["Furnace Design and Calibration of High-Temperature Continuous Photograph Powder X-Ray Camera."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Material Science"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Material Science"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:03:21Z"}