{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/1226"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/1226","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Design of two-axis capacitive accelerometer using MEMS","abstract":"MEMS technology is rapidly taking an important role in today's and future military systems. MEMS are able to lower the device size from millimeter to micrometer and maintain and sometimes surpass the performance of conventional devices. This thesis encompasses the knowledge acquired throughout the MEMS courses to design a two-axis capacitive accelerometer. The required acceleration and operating temperature range were Å 50g in each axis and -40Ê»C to +80 Ê»C, respectively. The accelerometer was also needed to survive within a dynamic shocking environment with accelerations of up to 225g. The parameters of the accelerometer to achieve above specifications were calculated using lumped element approximation and the results were used for initial layout of it. A finite element analysis code (ANSYS) was used to perform simulations of the accelerometer under various operating conditions and to determine the optimum configuration. The simulated results were found to be within about 5% of the calculations indicating the validity of lumped element approach. The response of the designed accelerometer was 7 mV/g and with sensitivity of 1.3g at 3dB. It was also found that the accelerometer was stable in the desired range of operation including under the shock. Two axes sensing can be achieved using two identical accelerometers having their sensing axes perpendicular to each other.","abstract_html":"MEMS technology is rapidly taking an important role in today&#x27;s and future military systems. MEMS are able to lower the device size from millimeter to micrometer and maintain and sometimes surpass the performance of conventional devices. This thesis encompasses the knowledge acquired throughout the MEMS courses to design a two-axis capacitive accelerometer. The required acceleration and operating temperature range were Å 50g in each axis and -40Ê»C to +80 Ê»C, respectively. The accelerometer was also needed to survive within a dynamic shocking environment with accelerations of up to 225g. The parameters of the accelerometer to achieve above specifications were calculated using lumped element approximation and the results were used for initial layout of it. A finite element analysis code (ANSYS) was used to perform simulations of the accelerometer under various operating conditions and to determine the optimum configuration. The simulated results were found to be within about 5% of the calculations indicating the validity of lumped element approach. The response of the designed accelerometer was 7 mV/g and with sensitivity of 1.3g at 3dB. It was also found that the accelerometer was stable in the desired range of operation including under the shock. Two axes sensing can be achieved using two identical accelerometers having their sensing axes perpendicular to each other.","abstract_has_math":false,"creators":["Lee, Chun Ming"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":"National Security Affairs (NSA)","school":null,"contributors":[],"advisors":["Karunasiri, Gamani"],"committee_chairs":[],"committee_members":["Sinibaldi, Jose"],"year":2004,"date_issued":"2004-12","date_published":"2004-12","updated_at":"2026-11-19T06:03:21Z","subjects":["Accelerometers","Microelectromechanical systems"],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/1226","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/1226","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F1226","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F1226","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Karunasiri, Gamani"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sinibaldi, Jose"]},{"key":"dc:contributor.department","label":"Department","values":["National Security Affairs (NSA)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Lee, Chun Ming"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:30:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:30:59Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Accelerometers","Finite Element Analysis","Simulation","Temperature","Optimization","Detection","Acceleration","Theses","Millimeter Waves","Coding","Configurations","Axes, Operation","Range(Extremes)","Micrometers"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Accelerometers","Microelectromechanical systems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/1226"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["MEMS technology is rapidly taking an important role in today's and future military systems. MEMS are able to lower the device size from millimeter to micrometer and maintain and sometimes surpass the performance of conventional devices. This thesis encompasses the knowledge acquired throughout the MEMS courses to design a two-axis capacitive accelerometer. The required acceleration and operating temperature range were Å 50g in each axis and -40Ê»C to +80 Ê»C, respectively. The accelerometer was also needed to survive within a dynamic shocking environment with accelerations of up to 225g. The parameters of the accelerometer to achieve above specifications were calculated using lumped element approximation and the results were used for initial layout of it. A finite element analysis code (ANSYS) was used to perform simulations of the accelerometer under various operating conditions and to determine the optimum configuration. The simulated results were found to be within about 5% of the calculations indicating the validity of lumped element approach. The response of the designed accelerometer was 7 mV/g and with sensitivity of 1.3g at 3dB. It was also found that the accelerometer was stable in the desired range of operation including under the shock. Two axes sensing can be achieved using two identical accelerometers having their sensing axes perpendicular to each other."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/designoftwoaxisc109451226"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 43 p. : ill. (some col.) ;"]},{"key":"dc:title","label":"Title","values":["Design of two-axis capacitive accelerometer using MEMS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Major, Taiwan Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Karunasiri, Gamani"],"dc:contributor.committeemember":["Sinibaldi, Jose"],"dc:contributor.department":["National Security Affairs (NSA)"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Lee, Chun Ming"],"dc:date.accessioned":["2012-03-14T17:30:59Z"],"dc:date.available":["2012-03-14T17:30:59Z"],"dc:date.issued":["2004-12"],"dc:description.abstract":["MEMS technology is rapidly taking an important role in today's and future military systems. MEMS are able to lower the device size from millimeter to micrometer and maintain and sometimes surpass the performance of conventional devices. This thesis encompasses the knowledge acquired throughout the MEMS courses to design a two-axis capacitive accelerometer. The required acceleration and operating temperature range were Å 50g in each axis and -40Ê»C to +80 Ê»C, respectively. The accelerometer was also needed to survive within a dynamic shocking environment with accelerations of up to 225g. The parameters of the accelerometer to achieve above specifications were calculated using lumped element approximation and the results were used for initial layout of it. A finite element analysis code (ANSYS) was used to perform simulations of the accelerometer under various operating conditions and to determine the optimum configuration. The simulated results were found to be within about 5% of the calculations indicating the validity of lumped element approach. The response of the designed accelerometer was 7 mV/g and with sensitivity of 1.3g at 3dB. It was also found that the accelerometer was stable in the desired range of operation including under the shock. Two axes sensing can be achieved using two identical accelerometers having their sensing axes perpendicular to each other."],"dc:description.uri":["http://archive.org/details/designoftwoaxisc109451226"],"dc:format.extent":["xiv, 43 p. : ill. (some col.) ;"],"dc:identifier.uri":["https://hdl.handle.net/10945/1226"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Accelerometers","Finite Element Analysis","Simulation","Temperature","Optimization","Detection","Acceleration","Theses","Millimeter Waves","Coding","Configurations","Axes, Operation","Range(Extremes)","Micrometers"],"dc:subject.lcsh":["Accelerometers","Microelectromechanical systems"],"dc:title":["Design of two-axis capacitive accelerometer using MEMS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Major, Taiwan Army"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:03:21Z"}