{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/12579"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/12579","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Mach Y stems from spherical shocks: photo investigation of the effects of fractional gram charges","abstract":"An investigation of primary and reflected spherical shock wave phenomena was conducted by center-detonating spherical ¼ gram PETN (Penta-erythritol tetranitrate) charges and photographing the resulting shock waves. This was done at accurately timed intervals in the range of 40 to 1000 microseconds with a Polaroid camera in conjunction with a high intensity xenon flash tube as a light source. Clear and measureable photographs of the primary and reflected shock waves with associated Mach stem formation were obtained over the entire range of investigation. Since this paper represents the first data ever obtained on a laboratory scale of Mach stem phenomena, correlation of spherical shock wave parameters was necessarily made with available theoretical and experimental data by using primary shock wave data. Correlation results were excellent which shows that the Mach stem and other data contained herein are accurate and therefore reliable in determining high yield shock wave parameters by the use of appropriate scaling.","abstract_html":"An investigation of primary and reflected spherical shock wave phenomena was conducted by center-detonating spherical ¼ gram PETN (Penta-erythritol tetranitrate) charges and photographing the resulting shock waves. This was done at accurately timed intervals in the range of 40 to 1000 microseconds with a Polaroid camera in conjunction with a high intensity xenon flash tube as a light source. Clear and measureable photographs of the primary and reflected shock waves with associated Mach stem formation were obtained over the entire range of investigation. Since this paper represents the first data ever obtained on a laboratory scale of Mach stem phenomena, correlation of spherical shock wave parameters was necessarily made with available theoretical and experimental data by using primary shock wave data. Correlation results were excellent which shows that the Mach stem and other data contained herein are accurate and therefore reliable in determining high yield shock wave parameters by the use of appropriate scaling.","abstract_has_math":false,"creators":["Glenn, Dwight W.","Salin, Robert S."],"institution":"Monterey, California: U.S. Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":["Kinney, G.F."],"committee_chairs":[],"committee_members":[],"year":1960,"date_issued":"1960","date_published":"1960","updated_at":"2026-11-21T23:35:49Z","subjects":["Physics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/12579","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/12579","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F12579","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F12579","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kinney, G.F."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Glenn, Dwight W.","Salin, Robert S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1960"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:33:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:33:17Z"]},{"key":"dc:date.issued","label":"Date","values":["1960"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/12579"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An investigation of primary and reflected spherical shock wave phenomena was conducted by center-detonating spherical ¼ gram PETN (Penta-erythritol tetranitrate) charges and photographing the resulting shock waves. This was done at accurately timed intervals in the range of 40 to 1000 microseconds with a Polaroid camera in conjunction with a high intensity xenon flash tube as a light source. Clear and measureable photographs of the primary and reflected shock waves with associated Mach stem formation were obtained over the entire range of investigation. Since this paper represents the first data ever obtained on a laboratory scale of Mach stem phenomena, correlation of spherical shock wave parameters was necessarily made with available theoretical and experimental data by using primary shock wave data. Correlation results were excellent which shows that the Mach stem and other data contained herein are accurate and therefore reliable in determining high yield shock wave parameters by the use of appropriate scaling."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/machystemsfromsp1094512579"]},{"key":"dc:title","label":"Title","values":["Mach Y stems from spherical shocks: photo investigation of the effects of fractional gram charges"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["First Lieutenant, United States Army","Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kinney, G.F."],"dc:contributor.department":["Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Glenn, Dwight W.","Salin, Robert S."],"dc:date":["1960"],"dc:date.accessioned":["2012-08-29T23:33:17Z"],"dc:date.available":["2012-08-29T23:33:17Z"],"dc:date.issued":["1960"],"dc:description.abstract":["An investigation of primary and reflected spherical shock wave phenomena was conducted by center-detonating spherical ¼ gram PETN (Penta-erythritol tetranitrate) charges and photographing the resulting shock waves. This was done at accurately timed intervals in the range of 40 to 1000 microseconds with a Polaroid camera in conjunction with a high intensity xenon flash tube as a light source. Clear and measureable photographs of the primary and reflected shock waves with associated Mach stem formation were obtained over the entire range of investigation. Since this paper represents the first data ever obtained on a laboratory scale of Mach stem phenomena, correlation of spherical shock wave parameters was necessarily made with available theoretical and experimental data by using primary shock wave data. Correlation results were excellent which shows that the Mach stem and other data contained herein are accurate and therefore reliable in determining high yield shock wave parameters by the use of appropriate scaling."],"dc:description.uri":["http://archive.org/details/machystemsfromsp1094512579"],"dc:identifier.uri":["https://hdl.handle.net/10945/12579"],"dc:publisher":["Monterey, California: U.S. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Physics"],"dc:title":["Mach Y stems from spherical shocks: photo investigation of the effects of fractional gram charges"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["First Lieutenant, United States Army","Lieutenant, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:35:49Z"}