{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/12696"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/12696","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A multichannel electron detection system for use in a stabilized magnetic spectrometer","abstract":"Multichannel counting systems facilitate the determination of differential cross sections in electron scattering experiments. The need for a high resolution counting system capable of handling fast counting rates has led to the construction of a transistorized, multichannel system for use with the 100 Mev linear electron accelerator being constructed at the U.S. Naval Postgraduate School. Design and operation of the counting system are discussed, and testing procedures are described. Since accurate measurement and stability of the spectrometer magnetic field is of fundamental importance in the operation of the multichannel detector, an accurate rotating coil fluxmeter for measuring and regulating the spectrometer magnetic field has also been built and is described. More familiar techniques of magnetic field measurement are not suitable for this application. Measurement of magnet current does not yield sufficient accuracy due to variations in field strength not linearly related to magnet current, and nuclear­ magnetic resonance devices are impractical where there is an inhomogeneous field such as exists in a double focusing spec­trometer magnet. The fluxmeter measures and regulates field strength to an accuracy of one part in 1000 or one gauss, whichever is greater.","abstract_html":"Multichannel counting systems facilitate the determination of differential cross sections in electron scattering experiments. The need for a high resolution counting system capable of handling fast counting rates has led to the construction of a transistorized, multichannel system for use with the 100 Mev linear electron accelerator being constructed at the U.S. Naval Postgraduate School. Design and operation of the counting system are discussed, and testing procedures are described. Since accurate measurement and stability of the spectrometer magnetic field is of fundamental importance in the operation of the multichannel detector, an accurate rotating coil fluxmeter for measuring and regulating the spectrometer magnetic field has also been built and is described. More familiar techniques of magnetic field measurement are not suitable for this application. Measurement of magnet current does not yield sufficient accuracy due to variations in field strength not linearly related to magnet current, and nuclear­ magnetic resonance devices are impractical where there is an inhomogeneous field such as exists in a double focusing spec­trometer magnet. The fluxmeter measures and regulates field strength to an accuracy of one part in 1000 or one gauss, whichever is greater.","abstract_has_math":false,"creators":["Kenaston, George W.","Luke, C. Thomas, Jr.","Sones, William C."],"institution":"Monterey, California: U.S. Naval Postgraduate School","degree_name":"Master of Science in Physics","degree_level":"Masters","degree_discipline":null,"degree_department":"Physics","school":null,"contributors":[],"advisors":["Crittenden, E.C., Jr."],"committee_chairs":[],"committee_members":[],"year":1965,"date_issued":"1965","date_published":"1965","updated_at":"2026-11-21T22:36:19Z","subjects":["Nuclear physics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/12696","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/12696","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F12696","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F12696","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Crittenden, E.C., Jr."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["Kenaston, George W.","Luke, C. Thomas, Jr.","Sones, William C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1965"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:33:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:33:49Z"]},{"key":"dc:date.issued","label":"Date","values":["1965"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Nuclear physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/12696"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Multichannel counting systems facilitate the determination of differential cross sections in electron scattering experiments. The need for a high resolution counting system capable of handling fast counting rates has led to the construction of a transistorized, multichannel system for use with the 100 Mev linear electron accelerator being constructed at the U.S. Naval Postgraduate School. Design and operation of the counting system are discussed, and testing procedures are described. Since accurate measurement and stability of the spectrometer magnetic field is of fundamental importance in the operation of the multichannel detector, an accurate rotating coil fluxmeter for measuring and regulating the spectrometer magnetic field has also been built and is described. More familiar techniques of magnetic field measurement are not suitable for this application. Measurement of magnet current does not yield sufficient accuracy due to variations in field strength not linearly related to magnet current, and nuclear­ magnetic resonance devices are impractical where there is an inhomogeneous field such as exists in a double focusing spec­trometer magnet. The fluxmeter measures and regulates field strength to an accuracy of one part in 1000 or one gauss, whichever is greater."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/amultichannelele1094512696"]},{"key":"dc:title","label":"Title","values":["A multichannel electron detection system for use in a stabilized magnetic spectrometer"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Crittenden, E.C., Jr."],"dc:contributor.department":["Physics"],"dc:creator":["Kenaston, George W.","Luke, C. Thomas, Jr.","Sones, William C."],"dc:date":["1965"],"dc:date.accessioned":["2012-08-29T23:33:49Z"],"dc:date.available":["2012-08-29T23:33:49Z"],"dc:date.issued":["1965"],"dc:description.abstract":["Multichannel counting systems facilitate the determination of differential cross sections in electron scattering experiments. The need for a high resolution counting system capable of handling fast counting rates has led to the construction of a transistorized, multichannel system for use with the 100 Mev linear electron accelerator being constructed at the U.S. Naval Postgraduate School. Design and operation of the counting system are discussed, and testing procedures are described. Since accurate measurement and stability of the spectrometer magnetic field is of fundamental importance in the operation of the multichannel detector, an accurate rotating coil fluxmeter for measuring and regulating the spectrometer magnetic field has also been built and is described. More familiar techniques of magnetic field measurement are not suitable for this application. Measurement of magnet current does not yield sufficient accuracy due to variations in field strength not linearly related to magnet current, and nuclear­ magnetic resonance devices are impractical where there is an inhomogeneous field such as exists in a double focusing spec­trometer magnet. The fluxmeter measures and regulates field strength to an accuracy of one part in 1000 or one gauss, whichever is greater."],"dc:description.uri":["http://archive.org/details/amultichannelele1094512696"],"dc:identifier.uri":["https://hdl.handle.net/10945/12696"],"dc:publisher":["Monterey, California: U.S. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Nuclear physics"],"dc:title":["A multichannel electron detection system for use in a stabilized magnetic spectrometer"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:36:19Z"}