{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/12806"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/12806","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A parametric analysis of a deep sea radioisotopic thermoelectric generator employing a heat pipe.","abstract":"A parametric design analysis was performed using a heat pipe in an existing deep sea Radioisotopic Thermoelectric Generator (SNAP-21). Heat is transferred from an annular fuel pellet to an annular thermoelectric generator through a connecting heat pipe. The fuel pellet is fully shielded so that the thermoelectric generator is easily removable. Overall efficiency and the weight of major components were determined for varying fuel radii of from 1.3 inches to 1.7 inches and for varying insulation thicknesses of from 1.0 inch to 2.0 inch. The analysis indicates that there is a particular fuel radius (at constant insulation thickness) at which minimum weight is reached, while the maximum overall efficiency (at the beginning of life) of 5.4% and a total weight of 570 lbs. These design results, when compared to the existing SNAP-21 design gives an increase in overall efficiency of at least 7%, and a reduction in total weight of 12%.","abstract_html":"A parametric design analysis was performed using a heat pipe in an existing deep sea Radioisotopic Thermoelectric Generator (SNAP-21). Heat is transferred from an annular fuel pellet to an annular thermoelectric generator through a connecting heat pipe. The fuel pellet is fully shielded so that the thermoelectric generator is easily removable. Overall efficiency and the weight of major components were determined for varying fuel radii of from 1.3 inches to 1.7 inches and for varying insulation thicknesses of from 1.0 inch to 2.0 inch. The analysis indicates that there is a particular fuel radius (at constant insulation thickness) at which minimum weight is reached, while the maximum overall efficiency (at the beginning of life) of 5.4% and a total weight of 570 lbs. These design results, when compared to the existing SNAP-21 design gives an increase in overall efficiency of at least 7%, and a reduction in total weight of 12%.","abstract_has_math":false,"creators":["Ewers, Benjamin James Jr."],"institution":"Monterey, California. U.S. Naval Postgraduate School","degree_name":"M.S.in Mechanical Engineering","degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Marto, Paul J."],"committee_chairs":[],"committee_members":[],"year":1969,"date_issued":"1969-06","date_published":"1969-06","updated_at":"2026-11-24T23:54:39Z","subjects":["Mechanical engineering"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/12806","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/12806","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F12806","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F12806","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, Paul J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Ewers, Benjamin James Jr."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1969"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:34:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:34:18Z"]},{"key":"dc:date.issued","label":"Date","values":["1969-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["radioisotopic thermoelectric generator","heat pipe","SNAP-21"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/12806"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A parametric design analysis was performed using a heat pipe in an existing deep sea Radioisotopic Thermoelectric Generator (SNAP-21). Heat is transferred from an annular fuel pellet to an annular thermoelectric generator through a connecting heat pipe. The fuel pellet is fully shielded so that the thermoelectric generator is easily removable. Overall efficiency and the weight of major components were determined for varying fuel radii of from 1.3 inches to 1.7 inches and for varying insulation thicknesses of from 1.0 inch to 2.0 inch. The analysis indicates that there is a particular fuel radius (at constant insulation thickness) at which minimum weight is reached, while the maximum overall efficiency (at the beginning of life) of 5.4% and a total weight of 570 lbs. These design results, when compared to the existing SNAP-21 design gives an increase in overall efficiency of at least 7%, and a reduction in total weight of 12%."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/aparametricnalys1094512806"]},{"key":"dc:title","label":"Title","values":["A parametric analysis of a deep sea radioisotopic thermoelectric generator employing a heat pipe."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Junior Grade, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, Paul J."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Ewers, Benjamin James Jr."],"dc:date":["June 1969"],"dc:date.accessioned":["2012-08-29T23:34:18Z"],"dc:date.available":["2012-08-29T23:34:18Z"],"dc:date.issued":["1969-06"],"dc:description.abstract":["A parametric design analysis was performed using a heat pipe in an existing deep sea Radioisotopic Thermoelectric Generator (SNAP-21). Heat is transferred from an annular fuel pellet to an annular thermoelectric generator through a connecting heat pipe. The fuel pellet is fully shielded so that the thermoelectric generator is easily removable. Overall efficiency and the weight of major components were determined for varying fuel radii of from 1.3 inches to 1.7 inches and for varying insulation thicknesses of from 1.0 inch to 2.0 inch. The analysis indicates that there is a particular fuel radius (at constant insulation thickness) at which minimum weight is reached, while the maximum overall efficiency (at the beginning of life) of 5.4% and a total weight of 570 lbs. These design results, when compared to the existing SNAP-21 design gives an increase in overall efficiency of at least 7%, and a reduction in total weight of 12%."],"dc:description.uri":["http://archive.org/details/aparametricnalys1094512806"],"dc:identifier.uri":["https://hdl.handle.net/10945/12806"],"dc:publisher":["Monterey, California. U.S. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["radioisotopic thermoelectric generator","heat pipe","SNAP-21"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["A parametric analysis of a deep sea radioisotopic thermoelectric generator employing a heat pipe."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Junior Grade, United States Navy"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-24T23:54:39Z"}