{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/13091"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/13091","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Spectroscopic study of a magnetically confined nitrogen plasma column.","abstract":"The Plasma Spectrophotometer constructed at the Naval Postgraduate School in 1968 was modified by the addition of a photomultiplier cooling device to improve time resolution and increase the accuracy of the computer values of the relative intensities of the nitrogen spectrum in the magnetically confined nitrogen plasma column. The relative intensities determined were used to analyze the variation in local electron temperature of the singly and doubly ionized nitrogen atoms with respect to magnetic field. The local electron temperature was found to vary with increasing magnetic filed, reaching a peak temperature of 8.1 electron volts at 4200 gauss. Evaluation of the relative number densities of the two ionic species indicated that the local electron temperature of the column was the local electron temperature of the singly ionized nitrogen atom.","abstract_html":"The Plasma Spectrophotometer constructed at the Naval Postgraduate School in 1968 was modified by the addition of a photomultiplier cooling device to improve time resolution and increase the accuracy of the computer values of the relative intensities of the nitrogen spectrum in the magnetically confined nitrogen plasma column. The relative intensities determined were used to analyze the variation in local electron temperature of the singly and doubly ionized nitrogen atoms with respect to magnetic field. The local electron temperature was found to vary with increasing magnetic filed, reaching a peak temperature of 8.1 electron volts at 4200 gauss. Evaluation of the relative number densities of the two ionic species indicated that the local electron temperature of the column was the local electron temperature of the singly ionized nitrogen atom.","abstract_has_math":false,"creators":["Cote, Joseph Robert"],"institution":"Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Kalmbach, Sydney H."],"committee_chairs":[],"committee_members":[],"year":1969,"date_issued":"1969-06","date_published":"1969-06","updated_at":"2026-11-21T22:28:51Z","subjects":["Physics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm640309431"],"render_values":[{"text":"ocm640309431","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/13091","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/13091","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F13091","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F13091","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kalmbach, Sydney H."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Cote, Joseph Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1969"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-29T23:35:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-29T23:35:47Z"]},{"key":"dc:date.issued","label":"Date","values":["1969-06"]},{"key":"dc:publisher","label":"Institution","values":["Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Plasma spectrophotometer","Nitrogen plasma","Local electron temperature"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm640309431"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/13091"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Plasma Spectrophotometer constructed at the Naval Postgraduate School in 1968 was modified by the addition of a photomultiplier cooling device to improve time resolution and increase the accuracy of the computer values of the relative intensities of the nitrogen spectrum in the magnetically confined nitrogen plasma column. The relative intensities determined were used to analyze the variation in local electron temperature of the singly and doubly ionized nitrogen atoms with respect to magnetic field. The local electron temperature was found to vary with increasing magnetic filed, reaching a peak temperature of 8.1 electron volts at 4200 gauss. Evaluation of the relative number densities of the two ionic species indicated that the local electron temperature of the column was the local electron temperature of the singly ionized nitrogen atom."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/spectroscopicstu1094513091"]},{"key":"dc:title","label":"Title","values":["Spectroscopic study of a magnetically confined nitrogen plasma column."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Major, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kalmbach, Sydney H."],"dc:contributor.department":["Department of Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Cote, Joseph Robert"],"dc:date":["June 1969"],"dc:date.accessioned":["2012-08-29T23:35:47Z"],"dc:date.available":["2012-08-29T23:35:47Z"],"dc:date.issued":["1969-06"],"dc:description.abstract":["The Plasma Spectrophotometer constructed at the Naval Postgraduate School in 1968 was modified by the addition of a photomultiplier cooling device to improve time resolution and increase the accuracy of the computer values of the relative intensities of the nitrogen spectrum in the magnetically confined nitrogen plasma column. The relative intensities determined were used to analyze the variation in local electron temperature of the singly and doubly ionized nitrogen atoms with respect to magnetic field. The local electron temperature was found to vary with increasing magnetic filed, reaching a peak temperature of 8.1 electron volts at 4200 gauss. Evaluation of the relative number densities of the two ionic species indicated that the local electron temperature of the column was the local electron temperature of the singly ionized nitrogen atom."],"dc:description.uri":["http://archive.org/details/spectroscopicstu1094513091"],"dc:identifier.oclc":["ocm640309431"],"dc:identifier.uri":["https://hdl.handle.net/10945/13091"],"dc:publisher":["Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Plasma spectrophotometer","Nitrogen plasma","Local electron temperature"],"dc:subject.lcsh":["Physics"],"dc:title":["Spectroscopic study of a magnetically confined nitrogen plasma column."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Major, United States Army"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:28:51Z"}